{"title":"[Clinical efficacy and safety of transcatheter aortic valve replacement for patients with severe pure native aortic regurgitation].","authors":"Jiantao Chen, Yi Zhang, Kangni Feng, Suiqing Huang, Hanri Xiao, Mengya Liang, Zhongkai Wu","doi":"10.3724/zdxbyxb-2024-0515","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the early clinical efficacy and safety of trans-catheter aortic valve replacement (TAVR) for patients with severe pure native aortic regurgitation (PNAR) who are not suitable for conventional surgical aortic valve replace-ment.</p><p><strong>Methods: </strong>A retrospective analysis was conducted on 48 patients with PNAR who underwent TAVR at the Department of Cardiac Surgery, the First Affiliated Hospital of Sun Yat-sen University between March 2019 and February 2025. These included 25 cases with transfemoral approach (TF-TAVR group) and 23 cases with transapical approach (TA-TAVR group). Efficacy and safety were assessed by analyzing baseline characteristics, all-cause mortality, and procedure-related complications.</p><p><strong>Results: </strong>Compared with the TA-TAVR group, the TF-TAVR group exhibited significantly smaller aortic annulus circumference and diameter, left ventricular outflow tract circumference and diameter, diameters of the left, right, and non-coronary sinuses, and sinotubular junction (STJ) diameter, along with a shorter distance from the STJ to the aortic annular plane ring plane, a smaller annulus angle (all <i>P</i><0.05). Additionally, the TF-TAVR group showed a deeper prosthesis implantation depth relative to the aortic annular plane (<i>P</i><0.01). The overall technical success rate was 91.67%, and the device success rate was 83.33%. Post-TAVR, both groups demonstrated significant improvement in left ventricular end-diastolic diameter (both <i>P</i><0.05), while only the TA-TAVR group showed significant reduction in left ventricular end-systolic diameter (<i>P</i><0.05). For primary outcomes, in-hospital mortality occurred in 2 patients (4.17%). No additional deaths were reported at 60 or 90 d after surgery. During 90-180 d after surgery, one patient in the TF-TAVR group died of sudden cardiac death, and one in the TA-TAVR group died of gastroin-testinal bleeding. During 180 d-1 year after surgery, one patient in the TF-TAVR group died of low cardiac output syndrome. No statistically significant differences were observed in 1-year Kaplan-Meier survival curves between the two groups (<i>P</i>>0.05). No conduction block events occurred in TA-TAVR group during hospitalization or 1-year follow-up, while high-grade atrioventricular block, left bundle branch block, permanent pacemaker implantation occurred in TF-TAVR group during hospitalization (12.00%, 4.00%, and 12.00%, respectively).</p><p><strong>Conclusions: </strong>TAVR demonstrates high feasibility and acceptable safety for severe PNAR patients who are not suitable for conventional SAVR. Both TF-TAVR and TA-TAVR show comparable early postoperative efficacy and safety profiles.</p>","PeriodicalId":24007,"journal":{"name":"Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences","volume":" ","pages":"529-540"},"PeriodicalIF":0.0000,"publicationDate":"2025-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3724/zdxbyxb-2024-0515","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: To evaluate the early clinical efficacy and safety of trans-catheter aortic valve replacement (TAVR) for patients with severe pure native aortic regurgitation (PNAR) who are not suitable for conventional surgical aortic valve replace-ment.
Methods: A retrospective analysis was conducted on 48 patients with PNAR who underwent TAVR at the Department of Cardiac Surgery, the First Affiliated Hospital of Sun Yat-sen University between March 2019 and February 2025. These included 25 cases with transfemoral approach (TF-TAVR group) and 23 cases with transapical approach (TA-TAVR group). Efficacy and safety were assessed by analyzing baseline characteristics, all-cause mortality, and procedure-related complications.
Results: Compared with the TA-TAVR group, the TF-TAVR group exhibited significantly smaller aortic annulus circumference and diameter, left ventricular outflow tract circumference and diameter, diameters of the left, right, and non-coronary sinuses, and sinotubular junction (STJ) diameter, along with a shorter distance from the STJ to the aortic annular plane ring plane, a smaller annulus angle (all P<0.05). Additionally, the TF-TAVR group showed a deeper prosthesis implantation depth relative to the aortic annular plane (P<0.01). The overall technical success rate was 91.67%, and the device success rate was 83.33%. Post-TAVR, both groups demonstrated significant improvement in left ventricular end-diastolic diameter (both P<0.05), while only the TA-TAVR group showed significant reduction in left ventricular end-systolic diameter (P<0.05). For primary outcomes, in-hospital mortality occurred in 2 patients (4.17%). No additional deaths were reported at 60 or 90 d after surgery. During 90-180 d after surgery, one patient in the TF-TAVR group died of sudden cardiac death, and one in the TA-TAVR group died of gastroin-testinal bleeding. During 180 d-1 year after surgery, one patient in the TF-TAVR group died of low cardiac output syndrome. No statistically significant differences were observed in 1-year Kaplan-Meier survival curves between the two groups (P>0.05). No conduction block events occurred in TA-TAVR group during hospitalization or 1-year follow-up, while high-grade atrioventricular block, left bundle branch block, permanent pacemaker implantation occurred in TF-TAVR group during hospitalization (12.00%, 4.00%, and 12.00%, respectively).
Conclusions: TAVR demonstrates high feasibility and acceptable safety for severe PNAR patients who are not suitable for conventional SAVR. Both TF-TAVR and TA-TAVR show comparable early postoperative efficacy and safety profiles.