Joseph Busher , Edith Touchet-Valle , Jacob Degitz , Mary P. McDougall
{"title":"Circuit design for broadband decoupling in multi-coil multi-nuclear applications","authors":"Joseph Busher , Edith Touchet-Valle , Jacob Degitz , Mary P. McDougall","doi":"10.1016/j.jmr.2025.107924","DOIUrl":null,"url":null,"abstract":"<div><div>The wealth of information available from multinuclear magnetic resonance imaging and spectroscopy is largely untapped in the clinical setting. This is due to a multitude of challenges in the pipeline ranging from acquisition strategies, hardware design, processing, and interpretation/analysis. As a small part of addressing these challenges, this work presents a straightforward approach for broadband decoupling between coils. This circuit was created with the implementation of a series PIN diode and was evaluated on the bench and experimentally for <sup>1</sup>H, <sup>31</sup>P and <sup>23</sup>Na at 3 T. Individual coils were single-tuned with this decoupling network and stacked to enable a switched triple-tuned coil. These coils were evaluated in various purposefully coupled configurations and compared to a narrowband trap active detuning network to demonstrate potential modularity of this design. Narrowband trapped coils showed drops in SNR when combined with other coils, presumably due to coupling between receiver elements tuned to different frequencies. This broadband decoupling behavior was shown to be independent of positioning through coils oriented to be nearly perfectly geometrically coupled and the addition of a three-element array of the same size. This configuration was validated on a post-mortem pig to verify the losses of the network did not prohibit its use for preclinical imaging and spectroscopy applications. Although losses were incurred as a result of the broadband decoupling network, it enabled a modular design that can be adapted to a given study without significant compromise of the signal integrity and could eliminate the need for certain custom coils for multi-nuclear studies.</div></div>","PeriodicalId":16267,"journal":{"name":"Journal of magnetic resonance","volume":"378 ","pages":"Article 107924"},"PeriodicalIF":1.9000,"publicationDate":"2025-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of magnetic resonance","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1090780725000965","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
The wealth of information available from multinuclear magnetic resonance imaging and spectroscopy is largely untapped in the clinical setting. This is due to a multitude of challenges in the pipeline ranging from acquisition strategies, hardware design, processing, and interpretation/analysis. As a small part of addressing these challenges, this work presents a straightforward approach for broadband decoupling between coils. This circuit was created with the implementation of a series PIN diode and was evaluated on the bench and experimentally for 1H, 31P and 23Na at 3 T. Individual coils were single-tuned with this decoupling network and stacked to enable a switched triple-tuned coil. These coils were evaluated in various purposefully coupled configurations and compared to a narrowband trap active detuning network to demonstrate potential modularity of this design. Narrowband trapped coils showed drops in SNR when combined with other coils, presumably due to coupling between receiver elements tuned to different frequencies. This broadband decoupling behavior was shown to be independent of positioning through coils oriented to be nearly perfectly geometrically coupled and the addition of a three-element array of the same size. This configuration was validated on a post-mortem pig to verify the losses of the network did not prohibit its use for preclinical imaging and spectroscopy applications. Although losses were incurred as a result of the broadband decoupling network, it enabled a modular design that can be adapted to a given study without significant compromise of the signal integrity and could eliminate the need for certain custom coils for multi-nuclear studies.
期刊介绍:
The Journal of Magnetic Resonance presents original technical and scientific papers in all aspects of magnetic resonance, including nuclear magnetic resonance spectroscopy (NMR) of solids and liquids, electron spin/paramagnetic resonance (EPR), in vivo magnetic resonance imaging (MRI) and spectroscopy (MRS), nuclear quadrupole resonance (NQR) and magnetic resonance phenomena at nearly zero fields or in combination with optics. The Journal''s main aims include deepening the physical principles underlying all these spectroscopies, publishing significant theoretical and experimental results leading to spectral and spatial progress in these areas, and opening new MR-based applications in chemistry, biology and medicine. The Journal also seeks descriptions of novel apparatuses, new experimental protocols, and new procedures of data analysis and interpretation - including computational and quantum-mechanical methods - capable of advancing MR spectroscopy and imaging.