Improving diagnostic accuracy in cirrhotic patients: a comprehensive multicenter analysis of contrast-enhanced ultrasound-guided biopsy in a large cohort of 2056 patients.
IF 4.8 1区 医学Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Binbin Jiang, Xiang Jing, Yuxiang Wang, Xiaolin Zhu, Jing Wang, Ruiqing Du, Bin Lv, Kefeng Wang, Zhixiang Gao, Kun Yan
{"title":"Improving diagnostic accuracy in cirrhotic patients: a comprehensive multicenter analysis of contrast-enhanced ultrasound-guided biopsy in a large cohort of 2056 patients.","authors":"Binbin Jiang, Xiang Jing, Yuxiang Wang, Xiaolin Zhu, Jing Wang, Ruiqing Du, Bin Lv, Kefeng Wang, Zhixiang Gao, Kun Yan","doi":"10.1007/s11547-025-02034-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the factors influencing ultrasound-guided liver biopsy accuracy and develop a decision model for managing biopsy results.</p><p><strong>Materials and methods: </strong>This prospective study enrolled 2056 adult patients with focal hepatic lesions from nine Chinese hospitals. Diagnostic accuracy was calculated, and variables were analyzed using multivariate logistic regression. A prediction model was constructed using chi-square automatic interaction detection.</p><p><strong>Results: </strong>This study enrolled 2056 participants (1297 men, 759 women; mean age, 67.8 ± 10.8 years) with 2056 biopsied lesions (mean ± standard deviation: 4.0 ± 2.8 cm; range 0.7-17.7 cm), and 94.2% were accurately diagnosed. Two to three biopsy passes were significantly more accurate than one pass (95.1% vs. 87.3%, P < 0.001) and comparable to the accuracy of > 3 passes (95.1% vs. 93.2%, P = 0.408). Independent predictors of accurate diagnoses included absence of cirrhosis [2.428 (1.457-3.741), P < 0.001], CEUS guidance [1.899 (1.288-2.801), P = 0.001], and number of biopsy passes > 1 [1.775 (1.103-2.855), P = 0.018]. The predictive decision tree model demonstrated that for cirrhotic patients who underwent CEUS-guided biopsy, the probability of an accurate diagnosis increased from 88.3% (when US-guided biopsy was used) to 93.3%. Conversely, in noncirrhotic patients undergoing US-guided biopsy, a diagnostic accuracy probability of 96.4% was observed. The overall prediction accuracy of the model was 94.4%.</p><p><strong>Conclusion: </strong>CEUS-guided biopsy enhances diagnostic accuracy in cirrhotic patients, whereas US-guided biopsy is highly accurate in noncirrhotic patients. Two to three needle punctures are sufficient for 95% accuracy, with no additional improvement from more punctures.</p>","PeriodicalId":20817,"journal":{"name":"Radiologia Medica","volume":" ","pages":"1297-1306"},"PeriodicalIF":4.8000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiologia Medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11547-025-02034-7","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/7/1 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To investigate the factors influencing ultrasound-guided liver biopsy accuracy and develop a decision model for managing biopsy results.
Materials and methods: This prospective study enrolled 2056 adult patients with focal hepatic lesions from nine Chinese hospitals. Diagnostic accuracy was calculated, and variables were analyzed using multivariate logistic regression. A prediction model was constructed using chi-square automatic interaction detection.
Results: This study enrolled 2056 participants (1297 men, 759 women; mean age, 67.8 ± 10.8 years) with 2056 biopsied lesions (mean ± standard deviation: 4.0 ± 2.8 cm; range 0.7-17.7 cm), and 94.2% were accurately diagnosed. Two to three biopsy passes were significantly more accurate than one pass (95.1% vs. 87.3%, P < 0.001) and comparable to the accuracy of > 3 passes (95.1% vs. 93.2%, P = 0.408). Independent predictors of accurate diagnoses included absence of cirrhosis [2.428 (1.457-3.741), P < 0.001], CEUS guidance [1.899 (1.288-2.801), P = 0.001], and number of biopsy passes > 1 [1.775 (1.103-2.855), P = 0.018]. The predictive decision tree model demonstrated that for cirrhotic patients who underwent CEUS-guided biopsy, the probability of an accurate diagnosis increased from 88.3% (when US-guided biopsy was used) to 93.3%. Conversely, in noncirrhotic patients undergoing US-guided biopsy, a diagnostic accuracy probability of 96.4% was observed. The overall prediction accuracy of the model was 94.4%.
Conclusion: CEUS-guided biopsy enhances diagnostic accuracy in cirrhotic patients, whereas US-guided biopsy is highly accurate in noncirrhotic patients. Two to three needle punctures are sufficient for 95% accuracy, with no additional improvement from more punctures.
期刊介绍:
Felice Perussia founded La radiologia medica in 1914. It is a peer-reviewed journal and serves as the official journal of the Italian Society of Medical and Interventional Radiology (SIRM). The primary purpose of the journal is to disseminate information related to Radiology, especially advancements in diagnostic imaging and related disciplines. La radiologia medica welcomes original research on both fundamental and clinical aspects of modern radiology, with a particular focus on diagnostic and interventional imaging techniques. It also covers topics such as radiotherapy, nuclear medicine, radiobiology, health physics, and artificial intelligence in the context of clinical implications. The journal includes various types of contributions such as original articles, review articles, editorials, short reports, and letters to the editor. With an esteemed Editorial Board and a selection of insightful reports, the journal is an indispensable resource for radiologists and professionals in related fields. Ultimately, La radiologia medica aims to serve as a platform for international collaboration and knowledge sharing within the radiological community.