VALVE-IN-VALVE IMPLANTATION GONE SOUTH: A CASE REPORT.

IF 0.7 4区 医学 Q3 MEDICINE, GENERAL & INTERNAL
Robert Bernat, Volker Windmüller, Vasileios Leivaditis, Manfred Dahm, Burghard Schumacher
{"title":"VALVE-IN-VALVE IMPLANTATION GONE SOUTH: A CASE REPORT.","authors":"Robert Bernat, Volker Windmüller, Vasileios Leivaditis, Manfred Dahm, Burghard Schumacher","doi":"10.20471/acc.2024.63.s1.16","DOIUrl":null,"url":null,"abstract":"<p><p>Valve-in-Valve (ViV) procedures for failed surgical bioprostheses are becoming increasingly common. We present a case of a 73-year-old male patient with significant comorbidities who underwent a primary transcatheter aortic valve implantation (TAVI) with an Evolut 29 mm (Medtronic, Minneapolis, MN, USA) valve. This TAVI-prosthesis implantation failed due to the inability to fix the valve at the appropriate height to achieve an optimal hemodynamic result. The valve had to be snared and pulled into an adequate position and was then fixed by an implantation of another TAVI-prosthesis (29 mm Sapien S3, Edwards Lifesciences, Irvine, CA, USA) with optimal final result. The patient was discharged after significant clinical improvement and without further complications.</p>","PeriodicalId":7072,"journal":{"name":"Acta clinica Croatica","volume":"63 Suppl1","pages":"86-89"},"PeriodicalIF":0.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12207850/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta clinica Croatica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.20471/acc.2024.63.s1.16","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Valve-in-Valve (ViV) procedures for failed surgical bioprostheses are becoming increasingly common. We present a case of a 73-year-old male patient with significant comorbidities who underwent a primary transcatheter aortic valve implantation (TAVI) with an Evolut 29 mm (Medtronic, Minneapolis, MN, USA) valve. This TAVI-prosthesis implantation failed due to the inability to fix the valve at the appropriate height to achieve an optimal hemodynamic result. The valve had to be snared and pulled into an adequate position and was then fixed by an implantation of another TAVI-prosthesis (29 mm Sapien S3, Edwards Lifesciences, Irvine, CA, USA) with optimal final result. The patient was discharged after significant clinical improvement and without further complications.

瓣膜内植入失败一例报告。
对于失败的外科生物假体,瓣膜中瓣膜(ViV)手术正变得越来越普遍。我们报告一例73岁的男性患者,有明显的合并症,他接受了经导管主动脉瓣植入术(TAVI),瓣膜为Evolut 29 mm(美敦力,明尼阿波利斯,MN,美国)。由于无法将瓣膜固定在合适的高度以获得最佳的血流动力学结果,tavi假体植入失败。为了获得最佳的最终结果,必须将瓣膜诱捕并拉到适当的位置,然后通过植入另一个tavi假体(29 mm Sapien S3, Edwards Lifesciences, Irvine, CA, USA)进行固定。患者在临床显著改善后出院,无进一步并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta clinica Croatica
Acta clinica Croatica 医学-医学:内科
CiteScore
1.10
自引率
16.70%
发文量
38
审稿时长
6-12 weeks
期刊介绍: Acta Clinica Croatica is a peer reviewed general medical journal that publishes original articles that advance and improve medical science and practice and that serve the purpose of transfer of original and valuable information to journal readers. Acta Clinica Croatica is published in English four times a year.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信