Assessment of Clinical and Functional Outcomes of the Proximal Humerus Internal Locking Compression Plate in Different Neer's Types of Proximal Humeral Fracture: A Prospective Observational Study.

Mayur Kugashiya, Rajendra Kumar Pipal, Rajkumar P Sojitra, Jay Viraj Shah, Dharmendra Kumar Pipal, Seema Yadav
{"title":"Assessment of Clinical and Functional Outcomes of the Proximal Humerus Internal Locking Compression Plate in Different Neer's Types of Proximal Humeral Fracture: A Prospective Observational Study.","authors":"Mayur Kugashiya, Rajendra Kumar Pipal, Rajkumar P Sojitra, Jay Viraj Shah, Dharmendra Kumar Pipal, Seema Yadav","doi":"10.4103/jwas.jwas_55_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Over the years, various fixation methods have been developed for managing unstable proximal humerus fractures (PHFs), including conservative and surgical approaches like tension band wiring, suture fixation, intramedullary nailing, hemiarthroplasty, fixed-angled locking plates, and proximal humerus internal locking system (PHILOS) plating. Each method claims superior effectiveness as a fixation device.</p><p><strong>Aims: </strong>The study evaluated the functional outcome of the PHILOS in different parts of the PHF using the Constant-Murley score (CMS), which measures post-operative pain, daily activity ability, limb range of motion (ROM), and strength.</p><p><strong>Materials and methods: </strong>A prospective observational study of 50 participants aged 16 years and above at Rajasthan Hospitals in Ahmedabad, conducted from July 2020 to July 2022, examined the use of the PHILOS for PHF treatment.</p><p><strong>Results: </strong>The results revealed that two-part fractures had a significantly higher mean CMS (72.4 ± 10.8) compared with three-part (60.8 ± 8.1) and four-part (59.3 ± 5.3) fractures. The <i>P</i> value of 0.0003 indicated that the difference in CMS score between two and three or four parts of PHF after fixing them with PHILOS was statistically significant.</p><p><strong>Conclusion: </strong>The study concludes that using a locking plate for PHFs consistently leads to positive clinical and functional outcomes, including improved CMS, daily living activities, and ROM.</p>","PeriodicalId":73993,"journal":{"name":"Journal of the West African College of Surgeons","volume":"15 3","pages":"298-305"},"PeriodicalIF":0.0000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12200797/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the West African College of Surgeons","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jwas.jwas_55_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Over the years, various fixation methods have been developed for managing unstable proximal humerus fractures (PHFs), including conservative and surgical approaches like tension band wiring, suture fixation, intramedullary nailing, hemiarthroplasty, fixed-angled locking plates, and proximal humerus internal locking system (PHILOS) plating. Each method claims superior effectiveness as a fixation device.

Aims: The study evaluated the functional outcome of the PHILOS in different parts of the PHF using the Constant-Murley score (CMS), which measures post-operative pain, daily activity ability, limb range of motion (ROM), and strength.

Materials and methods: A prospective observational study of 50 participants aged 16 years and above at Rajasthan Hospitals in Ahmedabad, conducted from July 2020 to July 2022, examined the use of the PHILOS for PHF treatment.

Results: The results revealed that two-part fractures had a significantly higher mean CMS (72.4 ± 10.8) compared with three-part (60.8 ± 8.1) and four-part (59.3 ± 5.3) fractures. The P value of 0.0003 indicated that the difference in CMS score between two and three or four parts of PHF after fixing them with PHILOS was statistically significant.

Conclusion: The study concludes that using a locking plate for PHFs consistently leads to positive clinical and functional outcomes, including improved CMS, daily living activities, and ROM.

Abstract Image

Abstract Image

评估肱骨近端内锁加压钢板治疗不同类型肱骨近端骨折的临床和功能效果:一项前瞻性观察研究。
背景:多年来,治疗不稳定肱骨近端骨折(phf)的固定方法有多种,包括保守和手术方法,如张力带钢丝、缝合固定、髓内钉、半关节成形术、固定角度锁定钢板和肱骨近端内锁定系统(PHILOS)钢板。每种方法都声称作为固定装置具有优越的有效性。目的:该研究使用Constant-Murley评分(CMS)评估PHF不同部位PHILOS的功能结局,该评分测量术后疼痛、日常活动能力、肢体活动范围(ROM)和力量。材料和方法:2020年7月至2022年7月,在艾哈迈达巴德拉贾斯坦医院对50名16岁及以上的参与者进行了一项前瞻性观察研究,研究了PHILOS在PHF治疗中的使用情况。结果:两段式骨折的平均CMS(72.4±10.8)明显高于三段式骨折(60.8±8.1)和四段式骨折(59.3±5.3)。P值为0.0003,说明PHF用PHILOS固定后两部分与三部分、四部分的CMS评分差异有统计学意义。结论:该研究得出结论,持续使用锁定钢板治疗phf可获得积极的临床和功能结果,包括改善CMS,日常生活活动和ROM。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信