Ida Marie Nørum Wigh, Jesper Erik Karl Staffansson Strandberg, Marianne Christina Harbo Mosgaard, Maja Boe, Mia Séne Lund Christensen, Simon Lykkeboe, Søren Lundbye-Christensen, Aase Handberg, Stine Krogh Venø
{"title":"Preanalytical stability of 17 analytes in whole blood during transportation.","authors":"Ida Marie Nørum Wigh, Jesper Erik Karl Staffansson Strandberg, Marianne Christina Harbo Mosgaard, Maja Boe, Mia Séne Lund Christensen, Simon Lykkeboe, Søren Lundbye-Christensen, Aase Handberg, Stine Krogh Venø","doi":"10.1080/00365513.2025.2524725","DOIUrl":null,"url":null,"abstract":"<p><p>Reliable biochemical measurements are essential to patient care and rely on the correct preanalytical handling of blood samples. In Denmark, whole blood samples are transported from general practitioners to local hospital laboratories daily, and whole blood stability for 10 h is required for analytes to be included in this transportation service in the North Jutland Region. Therefore, this study aimed to determine the stability of 17 analytes in whole blood during transportation and storage for 6 and 10 h at room temperature (21 °C). Ten randomly selected participants were included in the Department of Clinical Biochemistry at Aalborg University Hospital. Three serum vacutainer tubes were collected from each participant, and 17 analytes (lipoprotein a, immunoglobulin G1, β-2-Microglobulin, κ free light chain, λ free light chain, peptidyl peptidase A, protein, apolipoprotein B, insulin-like growth factor 1, somatotropin, thyroxin binding globulin, anticardiolipin antibodies IgM, prolactin, thyroid peroxidase antibodies, thyroglobulin, thyroglobulin antibodies,17-Hydroxyprogesterone) were measured at baseline, after 6 h, and after 10 h. All analytes showed 6- and 10-hour stability within the limits of the preestablished analytical variation, reflected by coefficients of variation, in the laboratory (accredited by ISO-15189). Thus, transportation and storage of whole blood at room temperature for 6 and 10 h did not result in significant changes in the levels of the 17 studied analytes. Therefore, all analytes were suitable for the transportation service in the North Jutland Region, Denmark.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"1-6"},"PeriodicalIF":1.4000,"publicationDate":"2025-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical & Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365513.2025.2524725","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0
Abstract
Reliable biochemical measurements are essential to patient care and rely on the correct preanalytical handling of blood samples. In Denmark, whole blood samples are transported from general practitioners to local hospital laboratories daily, and whole blood stability for 10 h is required for analytes to be included in this transportation service in the North Jutland Region. Therefore, this study aimed to determine the stability of 17 analytes in whole blood during transportation and storage for 6 and 10 h at room temperature (21 °C). Ten randomly selected participants were included in the Department of Clinical Biochemistry at Aalborg University Hospital. Three serum vacutainer tubes were collected from each participant, and 17 analytes (lipoprotein a, immunoglobulin G1, β-2-Microglobulin, κ free light chain, λ free light chain, peptidyl peptidase A, protein, apolipoprotein B, insulin-like growth factor 1, somatotropin, thyroxin binding globulin, anticardiolipin antibodies IgM, prolactin, thyroid peroxidase antibodies, thyroglobulin, thyroglobulin antibodies,17-Hydroxyprogesterone) were measured at baseline, after 6 h, and after 10 h. All analytes showed 6- and 10-hour stability within the limits of the preestablished analytical variation, reflected by coefficients of variation, in the laboratory (accredited by ISO-15189). Thus, transportation and storage of whole blood at room temperature for 6 and 10 h did not result in significant changes in the levels of the 17 studied analytes. Therefore, all analytes were suitable for the transportation service in the North Jutland Region, Denmark.
期刊介绍:
The Scandinavian Journal of Clinical and Laboratory Investigation is an international scientific journal covering clinically oriented biochemical and physiological research. Since the launch of the journal in 1949, it has been a forum for international laboratory medicine, closely related to, and edited by, The Scandinavian Society for Clinical Chemistry.
The journal contains peer-reviewed articles, editorials, invited reviews, and short technical notes, as well as several supplements each year. Supplements consist of monographs, and symposium and congress reports covering subjects within clinical chemistry and clinical physiology.