Application of the wireless wearable monitoring system improves the turnaround time in gastrointestinal endoscopy center.

IF 3.6 4区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Bo Zhu, Yu Huang, Yi Liu, Min Wang, Ling Liu
{"title":"Application of the wireless wearable monitoring system improves the turnaround time in gastrointestinal endoscopy center.","authors":"Bo Zhu, Yu Huang, Yi Liu, Min Wang, Ling Liu","doi":"10.1093/postmj/qgaf103","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To investigate whether the wireless monitoring system can reduce the turnaround time in gastrointestinal endoscopy center.</p><p><strong>Methods: </strong>Enrolled patients were randomly allocated to the study or control group. The primary outcome was the turnaround time. The secondary outcomes included the total time from entering examination room to discharge (T1), the total time of monitoring mean arterial pressure (T5), incidences of hypotension, bradycardia, and hypoxia, evaluation of the medical staff, and rate of effective monitoring.</p><p><strong>Results: </strong>166 patients were analyzed. The turnaround time of study group was significantly shorter than that of control group (1.49 ± 1.82 vs. 4.78 ± 3.77 min, P < .001). The study group had a significantly shorter T1 (44.69 ± 4.54 vs. 49.49 ± 5.53 min, P < .001), but a longer T5 (44.39 ± 4.38 vs. 42.21 ± 4.97 min, P = .012). The medical staff gave higher scores to the wireless monitoring system in terms of practicability and application value (P < .05), but gave equally high evaluations on data reliability (P > .05). The rate of effective monitoring was acceptable in both groups.</p><p><strong>Conclusion: </strong>Application of the wireless monitoring system in an endoscopy center is feasible and acceptable, and improves the turnaround time.</p><p><strong>Trial registration: </strong>This study was registered at the Chinese Clinical Trial Registry on 19 April 2024 (ChiCTR2400083277).</p>","PeriodicalId":20374,"journal":{"name":"Postgraduate Medical Journal","volume":" ","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2025-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Postgraduate Medical Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/postmj/qgaf103","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To investigate whether the wireless monitoring system can reduce the turnaround time in gastrointestinal endoscopy center.

Methods: Enrolled patients were randomly allocated to the study or control group. The primary outcome was the turnaround time. The secondary outcomes included the total time from entering examination room to discharge (T1), the total time of monitoring mean arterial pressure (T5), incidences of hypotension, bradycardia, and hypoxia, evaluation of the medical staff, and rate of effective monitoring.

Results: 166 patients were analyzed. The turnaround time of study group was significantly shorter than that of control group (1.49 ± 1.82 vs. 4.78 ± 3.77 min, P < .001). The study group had a significantly shorter T1 (44.69 ± 4.54 vs. 49.49 ± 5.53 min, P < .001), but a longer T5 (44.39 ± 4.38 vs. 42.21 ± 4.97 min, P = .012). The medical staff gave higher scores to the wireless monitoring system in terms of practicability and application value (P < .05), but gave equally high evaluations on data reliability (P > .05). The rate of effective monitoring was acceptable in both groups.

Conclusion: Application of the wireless monitoring system in an endoscopy center is feasible and acceptable, and improves the turnaround time.

Trial registration: This study was registered at the Chinese Clinical Trial Registry on 19 April 2024 (ChiCTR2400083277).

无线可穿戴监控系统的应用,提高了胃肠内镜中心的周转时间。
目的:探讨无线监护系统能否缩短胃肠内镜中心的周转时间。方法:将入组患者随机分为研究组和对照组。主要结果是周转时间。次要观察指标包括从进入检查室到出院总时间(T1)、监测平均动脉压总时间(T5)、低血压、心动过缓、缺氧发生率、医护人员评价、有效监测率。结果:对166例患者进行分析。研究组的周转时间明显短于对照组(1.49±1.82 min vs. 4.78±3.77 min, P < 0.05)。两组患者的有效监测率均可接受。结论:无线监护系统在内镜中心的应用是可行和可接受的,并缩短了周转时间。试验注册:本研究于2024年4月19日在中国临床试验注册中心注册(ChiCTR2400083277)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Postgraduate Medical Journal
Postgraduate Medical Journal 医学-医学:内科
CiteScore
8.50
自引率
2.00%
发文量
131
审稿时长
2.5 months
期刊介绍: Postgraduate Medical Journal is a peer reviewed journal published on behalf of the Fellowship of Postgraduate Medicine. The journal aims to support junior doctors and their teachers and contribute to the continuing professional development of all doctors by publishing papers on a wide range of topics relevant to the practicing clinician and teacher. Papers published in PMJ include those that focus on core competencies; that describe current practice and new developments in all branches of medicine; that describe relevance and impact of translational research on clinical practice; that provide background relevant to examinations; and papers on medical education and medical education research. PMJ supports CPD by providing the opportunity for doctors to publish many types of articles including original clinical research; reviews; quality improvement reports; editorials, and correspondence on clinical matters.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信