[Pseudoaneurysm Arose from the Side Branch of Vascular Graft after Thoracic Aortic Replacement].

Q4 Medicine
Masahiko Kawamura, Isao Nishijima, Shigenobu Senaha, Mitsuyoshi Shimoji, Yukio Kuniyoshi
{"title":"[Pseudoaneurysm Arose from the Side Branch of Vascular Graft after Thoracic Aortic Replacement].","authors":"Masahiko Kawamura, Isao Nishijima, Shigenobu Senaha, Mitsuyoshi Shimoji, Yukio Kuniyoshi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The patient is a 52-year-old man. He underwent ascending aortic replacement for acute aortic dissection 21 years ago and aortic root replacement 15 years ago. During postoperative follow up, a pseudoaneurysm of the ascending aorta was found. Cause of the pseudoaneurysm was supposed to be injury of the anastomotic site by a sternal wire. Since the pseudoaneurysm was enlarging, operation was indicated. Incising the pseudoaneurysm, we did not find silk threads that were used for ligation of the side branch of the vascular graft, and there was bleeding from the side branch. It is reported that silk threads lose strength in vivo over time. Previously, we had ligated side branches of vascular grafts only with silk threads. This experience led us to add polypropylene sutures for ligation of side branches.</p>","PeriodicalId":17841,"journal":{"name":"Kyobu geka. The Japanese journal of thoracic surgery","volume":"78 6","pages":"426-429"},"PeriodicalIF":0.0000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kyobu geka. The Japanese journal of thoracic surgery","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

The patient is a 52-year-old man. He underwent ascending aortic replacement for acute aortic dissection 21 years ago and aortic root replacement 15 years ago. During postoperative follow up, a pseudoaneurysm of the ascending aorta was found. Cause of the pseudoaneurysm was supposed to be injury of the anastomotic site by a sternal wire. Since the pseudoaneurysm was enlarging, operation was indicated. Incising the pseudoaneurysm, we did not find silk threads that were used for ligation of the side branch of the vascular graft, and there was bleeding from the side branch. It is reported that silk threads lose strength in vivo over time. Previously, we had ligated side branches of vascular grafts only with silk threads. This experience led us to add polypropylene sutures for ligation of side branches.

【胸主动脉置换术后血管移植侧支产生假性动脉瘤】。
患者为52岁男性。21年前因急性主动脉夹层行升主动脉置换术,15年前行主动脉根置换术。术后随访中发现一假性升主动脉动脉瘤。假性动脉瘤的原因被认为是胸骨线损伤了吻合口。假性动脉瘤增大,需要手术治疗。切开假性动脉瘤,我们没有发现用于结扎血管移植物侧支的丝线,并且侧支有出血。据报道,随着时间的推移,丝线在体内会失去强度。以前,我们只用丝线结扎血管移植物的侧支。这一经验使我们添加聚丙烯缝合线用于侧分支的结扎。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
213
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信