Feasibility of shortened scan acquisition time with IQ-SPECT technology using SMARTZOOM(TM) collimator in myocardial perfusion imaging.

Q3 Medicine
Saranya Thiruvengadam, Dinesh Kumar Gauthaman, Nikita Sampathirao, Indirani Elangovan, Shelley Simon
{"title":"Feasibility of shortened scan acquisition time with IQ-SPECT technology using SMARTZOOM(TM) collimator in myocardial perfusion imaging.","authors":"Saranya Thiruvengadam, Dinesh Kumar Gauthaman, Nikita Sampathirao, Indirani Elangovan, Shelley Simon","doi":"10.22038/aojnmb.2025.78149.1551","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>IQ-SPECT technology uses cardiac-specific SMARTZOOM(TM) collimator that can reduce the time required to acquire myocardial perfusion images to half (14 seconds/view) of a standard SPECT procedure. This study aimed to further shorten the scan acquisition time (7 seconds/view) using the SMARTZOOM(TM) collimator without compromising the image quality.</p><p><strong>Methods: </strong>This prospective observational study involved 50 patients (39 men and 11 women) who underwent myocardial perfusion studies using the SMARTZOOM(TM) collimator. The scans were acquired in 7 seconds/view (Group A) and 14 seconds/view (Group B). Attenuation-corrected (AC), non-attenuation-corrected (NAC), and polar maps were generated for both groups using the QGS/QPS software. The groups were qualitatively and quantitatively compared in terms of image quality, relative uptake score, summed scores, total perfusion deficit, and left ventricular ejection fraction (LVEF).</p><p><strong>Results: </strong>The image quality of both groups was comparable in the AC studies, whereas Group B was superior to Group A in the NAC studies. All images exhibited an image quality score of ≥3, which suggested adequate image quality. The mean LVEF values were 62.16 and 64.34 in Groups A and B, respectively (p-value 0.326). A strong positive correlation was observed between the two datasets (Pearson's r=0.59). The mean summed score in the AC images was 7.5 in both groups (p-value 0.49), and in the NAC images, the scores were 7.68 in Group A and 7.46 in Group B (p-value 0.46). The mean total perfusion deficits calculated using the 17-segment models were 11% and 16% in Group A and Group B, respectively, for the AC images (p-value 0.143) and 11.2% and 16.5% in Group A and Group B, respectively, for the NAC images (p-value 0.135). Significant differences were not noted in the calculation of the relative uptake score in segments 1- 17 for the AC and NAC images in Groups A and B.</p><p><strong>Conclusion: </strong>The findings from this study indicate that further shortening of the scan acquisition time to 7 seconds/view is possible in myocardial perfusion imaging using the SMARTZOOM(TM) collimator without compromising the scan quality and the results, thus improving patient comfort.</p>","PeriodicalId":8503,"journal":{"name":"Asia Oceania Journal of Nuclear Medicine and Biology","volume":"13 2","pages":"138-145"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12205125/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia Oceania Journal of Nuclear Medicine and Biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/aojnmb.2025.78149.1551","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: IQ-SPECT technology uses cardiac-specific SMARTZOOM(TM) collimator that can reduce the time required to acquire myocardial perfusion images to half (14 seconds/view) of a standard SPECT procedure. This study aimed to further shorten the scan acquisition time (7 seconds/view) using the SMARTZOOM(TM) collimator without compromising the image quality.

Methods: This prospective observational study involved 50 patients (39 men and 11 women) who underwent myocardial perfusion studies using the SMARTZOOM(TM) collimator. The scans were acquired in 7 seconds/view (Group A) and 14 seconds/view (Group B). Attenuation-corrected (AC), non-attenuation-corrected (NAC), and polar maps were generated for both groups using the QGS/QPS software. The groups were qualitatively and quantitatively compared in terms of image quality, relative uptake score, summed scores, total perfusion deficit, and left ventricular ejection fraction (LVEF).

Results: The image quality of both groups was comparable in the AC studies, whereas Group B was superior to Group A in the NAC studies. All images exhibited an image quality score of ≥3, which suggested adequate image quality. The mean LVEF values were 62.16 and 64.34 in Groups A and B, respectively (p-value 0.326). A strong positive correlation was observed between the two datasets (Pearson's r=0.59). The mean summed score in the AC images was 7.5 in both groups (p-value 0.49), and in the NAC images, the scores were 7.68 in Group A and 7.46 in Group B (p-value 0.46). The mean total perfusion deficits calculated using the 17-segment models were 11% and 16% in Group A and Group B, respectively, for the AC images (p-value 0.143) and 11.2% and 16.5% in Group A and Group B, respectively, for the NAC images (p-value 0.135). Significant differences were not noted in the calculation of the relative uptake score in segments 1- 17 for the AC and NAC images in Groups A and B.

Conclusion: The findings from this study indicate that further shortening of the scan acquisition time to 7 seconds/view is possible in myocardial perfusion imaging using the SMARTZOOM(TM) collimator without compromising the scan quality and the results, thus improving patient comfort.

SMARTZOOM(TM)准直器在心肌灌注成像中缩短IQ-SPECT技术扫描采集时间的可行性。
目的:IQ-SPECT技术使用心脏专用的SMARTZOOM(TM)准直器,可以将获取心肌灌注图像所需的时间减少到标准SPECT程序的一半(14秒/视图)。本研究旨在使用SMARTZOOM(TM)准直器在不影响图像质量的情况下进一步缩短扫描采集时间(7秒/次)。方法:本前瞻性观察研究纳入50例患者(39例男性,11例女性),使用SMARTZOOM(TM)准直仪进行心肌灌注研究。扫描时间分别为7秒/次(A组)和14秒/次(B组)。使用QGS/QPS软件生成两组的衰减校正图(AC)、非衰减校正图(NAC)和极坐标图。从图像质量、相对摄取评分、综合评分、总灌注缺陷和左室射血分数(LVEF)等方面对两组进行定性和定量比较。结果:在AC研究中,两组图像质量相当,而在NAC研究中,B组优于A组。所有图像的图像质量评分≥3分,表明图像质量良好。A、B组平均LVEF值分别为62.16、64.34 (p值0.326)。两个数据集之间存在很强的正相关(Pearson’s r=0.59)。两组AC影像的平均积分为7.5分(p值0.49),NAC影像A组的平均积分为7.68分,B组的平均积分为7.46分(p值0.46)。17段模型计算的AC图像的平均总灌注缺损A组和B组分别为11%和16% (p值0.143),NAC图像的平均灌注缺损A组和B组分别为11.2%和16.5% (p值0.135)。结论:本研究结果表明,在心肌灌注成像中,使用SMARTZOOM(TM)准直仪在不影响扫描质量和结果的情况下,进一步缩短扫描采集时间至7秒/次是可能的,从而提高了患者的舒适度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Asia Oceania Journal of Nuclear Medicine and Biology
Asia Oceania Journal of Nuclear Medicine and Biology Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
1.80
自引率
0.00%
发文量
28
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信