A feasibility study on non-invasive and non-contact jugular venous pulse measurement using 60 GHz FMCW radar.

IF 2.9 3区 综合性期刊 Q1 MULTIDISCIPLINARY SCIENCES
Royal Society Open Science Pub Date : 2025-06-25 eCollection Date: 2025-06-01 DOI:10.1098/rsos.242231
Shatabdi Das, Hadi Afsharan, Girish Dwivedi, Coen Arrow, Omid Kavehei
{"title":"A feasibility study on non-invasive and non-contact jugular venous pulse measurement using 60 GHz FMCW radar.","authors":"Shatabdi Das, Hadi Afsharan, Girish Dwivedi, Coen Arrow, Omid Kavehei","doi":"10.1098/rsos.242231","DOIUrl":null,"url":null,"abstract":"<p><p>The jugular venous pulse (JVP) reflects right atrial pressure and provides diagnostic insight into cardiovascular and pulmonary health. However, reliable assessment remains difficult due to neck adiposity, anatomical variability and suboptimal positioning. Although central venous catheterization is the gold standard, its invasive nature restricts routine or long-term use. This study introduces a non-invasive method for JVP estimation using a 60 GHz frequency-modulated continuous wave (FMCW) radar. The system captures venous pulsations at the skin surface and applies eigenbeamforming to enhance signal-to-noise ratio and pulse clarity. Radar parameters were optimized for signal fidelity and validated through morphological comparison with simultaneously recorded photoplethysmography (PPG) signals. Additionally, we compared radar-derived JVP signals with previously recorded catheterization data from a patient with early-stage heart failure to assess clinical relevance. Signal localization was successfully achieved within a direction-of-arrival (DoA) range of <math><mrow><mo>-</mo></mrow> <mrow><msup><mn>20</mn> <mo>∘</mo></msup> </mrow> </math> to <math><mrow><mo>+</mo></mrow> <mrow><msup><mn>20</mn> <mo>∘</mo></msup> </mrow> </math> , demonstrating the radar's precision. While the selected parameters consistently yielded good performance in our set-up, individual anatomical differences may require subject-specific calibration. These findings support the potential of 60 GHz FMCW radar for contactless JVP monitoring, with promising implications for early detection and remote management of heart failure.</p>","PeriodicalId":21525,"journal":{"name":"Royal Society Open Science","volume":"12 6","pages":"242231"},"PeriodicalIF":2.9000,"publicationDate":"2025-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12187424/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Royal Society Open Science","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.1098/rsos.242231","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

The jugular venous pulse (JVP) reflects right atrial pressure and provides diagnostic insight into cardiovascular and pulmonary health. However, reliable assessment remains difficult due to neck adiposity, anatomical variability and suboptimal positioning. Although central venous catheterization is the gold standard, its invasive nature restricts routine or long-term use. This study introduces a non-invasive method for JVP estimation using a 60 GHz frequency-modulated continuous wave (FMCW) radar. The system captures venous pulsations at the skin surface and applies eigenbeamforming to enhance signal-to-noise ratio and pulse clarity. Radar parameters were optimized for signal fidelity and validated through morphological comparison with simultaneously recorded photoplethysmography (PPG) signals. Additionally, we compared radar-derived JVP signals with previously recorded catheterization data from a patient with early-stage heart failure to assess clinical relevance. Signal localization was successfully achieved within a direction-of-arrival (DoA) range of - 20 to + 20 , demonstrating the radar's precision. While the selected parameters consistently yielded good performance in our set-up, individual anatomical differences may require subject-specific calibration. These findings support the potential of 60 GHz FMCW radar for contactless JVP monitoring, with promising implications for early detection and remote management of heart failure.

60 GHz FMCW雷达无创非接触式颈静脉脉搏测量的可行性研究。
颈静脉脉冲(JVP)反映右心房压力和提供诊断洞察心血管和肺部健康。然而,由于颈部肥胖、解剖变异和次优定位,可靠的评估仍然很困难。虽然中心静脉置管是金标准,但其侵入性限制了常规或长期使用。本文介绍了一种基于60 GHz调频连续波(FMCW)雷达的非侵入式JVP估计方法。该系统捕获皮肤表面的静脉脉动,并应用特征波束形成来提高信噪比和脉冲清晰度。对雷达参数进行了信号保真度优化,并通过与同时记录的光体积脉搏波(PPG)信号的形态学比较进行了验证。此外,我们将雷达获得的JVP信号与先前记录的早期心力衰竭患者的导管数据进行比较,以评估临床相关性。在- 20°到+ 20°的到达方向(DoA)范围内成功地实现了信号定位,证明了雷达的精度。虽然所选参数在我们的设置中始终产生良好的性能,但个体解剖差异可能需要受试者特定的校准。这些发现支持了60 GHz FMCW雷达用于非接触式JVP监测的潜力,对心力衰竭的早期检测和远程管理具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Royal Society Open Science
Royal Society Open Science Multidisciplinary-Multidisciplinary
CiteScore
6.00
自引率
0.00%
发文量
508
审稿时长
14 weeks
期刊介绍: Royal Society Open Science is a new open journal publishing high-quality original research across the entire range of science on the basis of objective peer-review. The journal covers the entire range of science and mathematics and will allow the Society to publish all the high-quality work it receives without the usual restrictions on scope, length or impact.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信