Wearable Ultrasound-Imaging-Based Visual Feedback (UVF) Training for Ankle Rehabilitation of Chronic Stroke Survivors: A Proof-of-Concept Randomized Crossover Study.

IF 4.9 3区 工程技术 Q1 CHEMISTRY, ANALYTICAL
Yu-Yan Luo, Chen Huang, Zhen Song, Vaheh Nazari, Arnold Yu-Lok Wong, Lin Yang, Mingjie Dong, Mingming Zhang, Yong-Ping Zheng, Amy Siu-Ngor Fu, Christina Zong-Hao Ma
{"title":"Wearable Ultrasound-Imaging-Based Visual Feedback (UVF) Training for Ankle Rehabilitation of Chronic Stroke Survivors: A Proof-of-Concept Randomized Crossover Study.","authors":"Yu-Yan Luo, Chen Huang, Zhen Song, Vaheh Nazari, Arnold Yu-Lok Wong, Lin Yang, Mingjie Dong, Mingming Zhang, Yong-Ping Zheng, Amy Siu-Ngor Fu, Christina Zong-Hao Ma","doi":"10.3390/bios15060365","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated the effect of wearable ultrasound-imaging-based visual feedback (UVF) on assisting paretic ankle dorsiflexion training of chronic stroke survivors. Thirty-three participants with unilateral hemiplegia performed maximal isometric contractions on an isokinetic dynamometer in randomized conditions with and without UVF that provided by a wearable ultrasound imaging system. Torque parameters (mean, peak, percentage of maximal voluntary contraction) and tibialis anterior muscle thickness were analyzed across different contraction phases. Statistical comparisons were conducted using paired <i>t</i>-tests or Wilcoxon tests. Correlation analyses were performed using Pearson's or Spearman's tests. Results demonstrated that UVF significantly improved torque output, as evidence by the increased percentage of maximal voluntary contraction (%MVC) during entire contractions (<i>p</i> = 0.007), increased mean (<i>p</i> ≤ 0.022) and peak (<i>p</i> ≤ 0.044) torque and the %MVC (<i>p</i> ≤ 0.004) during mid and end phases, and larger muscle thickness during mid contraction (<i>p</i> = 0.045). Moderate correlations were found between torque and muscle thickness (r ≥ 0.30, <i>p</i> ≤ 0.049). These findings preliminarily supported the positive outcomes of real-time wearable UVFs in enhancing paretic ankle dorsiflexion strength and force control during isometric contractions in chronic stroke survivors. While the developed and validated new training protocol may potentially serve as a practical adjunct to existing rehabilitation approaches, further investigations emphasizing the functional outcomes and clinical translations are still needed to verify the clinical utility.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"15 6","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2025-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12191287/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios15060365","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigated the effect of wearable ultrasound-imaging-based visual feedback (UVF) on assisting paretic ankle dorsiflexion training of chronic stroke survivors. Thirty-three participants with unilateral hemiplegia performed maximal isometric contractions on an isokinetic dynamometer in randomized conditions with and without UVF that provided by a wearable ultrasound imaging system. Torque parameters (mean, peak, percentage of maximal voluntary contraction) and tibialis anterior muscle thickness were analyzed across different contraction phases. Statistical comparisons were conducted using paired t-tests or Wilcoxon tests. Correlation analyses were performed using Pearson's or Spearman's tests. Results demonstrated that UVF significantly improved torque output, as evidence by the increased percentage of maximal voluntary contraction (%MVC) during entire contractions (p = 0.007), increased mean (p ≤ 0.022) and peak (p ≤ 0.044) torque and the %MVC (p ≤ 0.004) during mid and end phases, and larger muscle thickness during mid contraction (p = 0.045). Moderate correlations were found between torque and muscle thickness (r ≥ 0.30, p ≤ 0.049). These findings preliminarily supported the positive outcomes of real-time wearable UVFs in enhancing paretic ankle dorsiflexion strength and force control during isometric contractions in chronic stroke survivors. While the developed and validated new training protocol may potentially serve as a practical adjunct to existing rehabilitation approaches, further investigations emphasizing the functional outcomes and clinical translations are still needed to verify the clinical utility.

基于可穿戴超声成像的视觉反馈(UVF)训练用于慢性中风幸存者踝关节康复:一项概念验证的随机交叉研究。
本研究探讨了基于可穿戴超声成像的视觉反馈(UVF)对慢性脑卒中幸存者麻痹性踝关节背屈训练的辅助作用。33名患有单侧偏瘫的参与者在随机条件下在等速测力计上进行了最大的等速收缩,有或没有由可穿戴超声成像系统提供的UVF。分析不同收缩阶段的扭矩参数(平均值、峰值、最大自主收缩百分比)和胫骨前肌厚度。采用配对t检验或Wilcoxon检验进行统计学比较。使用Pearson’s或Spearman’s检验进行相关分析。结果表明,UVF显著提高了扭矩输出,在整个收缩过程中最大自主收缩百分比(%MVC)增加(p = 0.007),在中期和末期增加平均(p≤0.022)和峰值(p≤0.044)扭矩和%MVC (p≤0.004),在收缩中期增加肌肉厚度(p = 0.045)。扭力与肌肉厚度呈正相关(r≥0.30,p≤0.049)。这些研究结果初步支持了实时可穿戴UVFs在慢性卒中幸存者等长收缩期间增强麻痹性踝关节背屈强度和力控制方面的积极结果。虽然开发和验证的新训练方案可能潜在地作为现有康复方法的实用辅助,但仍需要进一步的研究,强调功能结果和临床翻译,以验证临床实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biosensors-Basel
Biosensors-Basel Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍: Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信