Wearable Ultrasound-Imaging-Based Visual Feedback (UVF) Training for Ankle Rehabilitation of Chronic Stroke Survivors: A Proof-of-Concept Randomized Crossover Study.
Yu-Yan Luo, Chen Huang, Zhen Song, Vaheh Nazari, Arnold Yu-Lok Wong, Lin Yang, Mingjie Dong, Mingming Zhang, Yong-Ping Zheng, Amy Siu-Ngor Fu, Christina Zong-Hao Ma
{"title":"Wearable Ultrasound-Imaging-Based Visual Feedback (UVF) Training for Ankle Rehabilitation of Chronic Stroke Survivors: A Proof-of-Concept Randomized Crossover Study.","authors":"Yu-Yan Luo, Chen Huang, Zhen Song, Vaheh Nazari, Arnold Yu-Lok Wong, Lin Yang, Mingjie Dong, Mingming Zhang, Yong-Ping Zheng, Amy Siu-Ngor Fu, Christina Zong-Hao Ma","doi":"10.3390/bios15060365","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated the effect of wearable ultrasound-imaging-based visual feedback (UVF) on assisting paretic ankle dorsiflexion training of chronic stroke survivors. Thirty-three participants with unilateral hemiplegia performed maximal isometric contractions on an isokinetic dynamometer in randomized conditions with and without UVF that provided by a wearable ultrasound imaging system. Torque parameters (mean, peak, percentage of maximal voluntary contraction) and tibialis anterior muscle thickness were analyzed across different contraction phases. Statistical comparisons were conducted using paired <i>t</i>-tests or Wilcoxon tests. Correlation analyses were performed using Pearson's or Spearman's tests. Results demonstrated that UVF significantly improved torque output, as evidence by the increased percentage of maximal voluntary contraction (%MVC) during entire contractions (<i>p</i> = 0.007), increased mean (<i>p</i> ≤ 0.022) and peak (<i>p</i> ≤ 0.044) torque and the %MVC (<i>p</i> ≤ 0.004) during mid and end phases, and larger muscle thickness during mid contraction (<i>p</i> = 0.045). Moderate correlations were found between torque and muscle thickness (r ≥ 0.30, <i>p</i> ≤ 0.049). These findings preliminarily supported the positive outcomes of real-time wearable UVFs in enhancing paretic ankle dorsiflexion strength and force control during isometric contractions in chronic stroke survivors. While the developed and validated new training protocol may potentially serve as a practical adjunct to existing rehabilitation approaches, further investigations emphasizing the functional outcomes and clinical translations are still needed to verify the clinical utility.</p>","PeriodicalId":48608,"journal":{"name":"Biosensors-Basel","volume":"15 6","pages":""},"PeriodicalIF":4.9000,"publicationDate":"2025-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12191287/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors-Basel","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bios15060365","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
This study investigated the effect of wearable ultrasound-imaging-based visual feedback (UVF) on assisting paretic ankle dorsiflexion training of chronic stroke survivors. Thirty-three participants with unilateral hemiplegia performed maximal isometric contractions on an isokinetic dynamometer in randomized conditions with and without UVF that provided by a wearable ultrasound imaging system. Torque parameters (mean, peak, percentage of maximal voluntary contraction) and tibialis anterior muscle thickness were analyzed across different contraction phases. Statistical comparisons were conducted using paired t-tests or Wilcoxon tests. Correlation analyses were performed using Pearson's or Spearman's tests. Results demonstrated that UVF significantly improved torque output, as evidence by the increased percentage of maximal voluntary contraction (%MVC) during entire contractions (p = 0.007), increased mean (p ≤ 0.022) and peak (p ≤ 0.044) torque and the %MVC (p ≤ 0.004) during mid and end phases, and larger muscle thickness during mid contraction (p = 0.045). Moderate correlations were found between torque and muscle thickness (r ≥ 0.30, p ≤ 0.049). These findings preliminarily supported the positive outcomes of real-time wearable UVFs in enhancing paretic ankle dorsiflexion strength and force control during isometric contractions in chronic stroke survivors. While the developed and validated new training protocol may potentially serve as a practical adjunct to existing rehabilitation approaches, further investigations emphasizing the functional outcomes and clinical translations are still needed to verify the clinical utility.
Biosensors-BaselBiochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
6.60
自引率
14.80%
发文量
983
审稿时长
11 weeks
期刊介绍:
Biosensors (ISSN 2079-6374) provides an advanced forum for studies related to the science and technology of biosensors and biosensing. It publishes original research papers, comprehensive reviews and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.