Is Hirschberg enough? - A comparative study of corneal light reflex test and alternate prism cover test in measuring comitant horizontal strabismus.

IF 1.4 4区 医学 Q3 OPHTHALMOLOGY
Insha-E-Qudrat Tirmizi, Sardar Mohammad Ali Ayaz Sadiq
{"title":"Is Hirschberg enough? - A comparative study of corneal light reflex test and alternate prism cover test in measuring comitant horizontal strabismus.","authors":"Insha-E-Qudrat Tirmizi, Sardar Mohammad Ali Ayaz Sadiq","doi":"10.1177/11206721251350810","DOIUrl":null,"url":null,"abstract":"<p><p>ObjectiveTo determine the mean difference in deviation in prism dioptres as measured by corneal light reflex test and alternate prism cover test in comitant horizontal strabismus to improve practice patterns.Materials and methodsStudy settingInstitute of Ophthalmology, Mayo Hospital, Lahore, Pakistan; Sardar Trust Eye Hospital, Lahore; The Eye Associates, Lahore, Pakistan.Study designCross-sectional study.ResultsThe study included a total of 69 patients (36 males, 33 females) aged between 16 to 68 years (mean 23.5 years), of which 48 (70%) had exotropia and 21 (30%) had esotropia. The angle of deviation for exotropia ranged from 12 to 87 prism dioptres (PD) (mean 44.23 ± 19.20 PD), while for esotropia it was from 10 PD to 104 PD (mean 47.19 ± 29.10 PD). The average difference between the angle of deviation as measured by the corneal light reflex test i.e. the Hirschberg test, compared to that by the alternate prism cover test (APCT) for severe deviations was significant (<i>p</i>-value < 0.05). The difference was also significant for severe exotropia and esotropia, as well as moderate esotropia.ConclusionThere is a statistically significant difference between the measurements obtained by the corneal light reflex test and those by the alternate prism cover test, with the corneal light reflex test being substantially less accurate. Moreover, this relationship varies with the angle of the deviation, with overestimations more likely to occur with mild deviations and underestimations with severe deviations.</p>","PeriodicalId":12000,"journal":{"name":"European Journal of Ophthalmology","volume":" ","pages":"11206721251350810"},"PeriodicalIF":1.4000,"publicationDate":"2025-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11206721251350810","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

ObjectiveTo determine the mean difference in deviation in prism dioptres as measured by corneal light reflex test and alternate prism cover test in comitant horizontal strabismus to improve practice patterns.Materials and methodsStudy settingInstitute of Ophthalmology, Mayo Hospital, Lahore, Pakistan; Sardar Trust Eye Hospital, Lahore; The Eye Associates, Lahore, Pakistan.Study designCross-sectional study.ResultsThe study included a total of 69 patients (36 males, 33 females) aged between 16 to 68 years (mean 23.5 years), of which 48 (70%) had exotropia and 21 (30%) had esotropia. The angle of deviation for exotropia ranged from 12 to 87 prism dioptres (PD) (mean 44.23 ± 19.20 PD), while for esotropia it was from 10 PD to 104 PD (mean 47.19 ± 29.10 PD). The average difference between the angle of deviation as measured by the corneal light reflex test i.e. the Hirschberg test, compared to that by the alternate prism cover test (APCT) for severe deviations was significant (p-value < 0.05). The difference was also significant for severe exotropia and esotropia, as well as moderate esotropia.ConclusionThere is a statistically significant difference between the measurements obtained by the corneal light reflex test and those by the alternate prism cover test, with the corneal light reflex test being substantially less accurate. Moreover, this relationship varies with the angle of the deviation, with overestimations more likely to occur with mild deviations and underestimations with severe deviations.

赫施伯格就够了吗?-角膜光反射试验与交替棱镜盖试验测量伴发性水平斜视的比较研究。
目的测定伴发性水平斜视患者角膜光反射试验和交替棱镜盖试验测得的棱镜屈光度偏差的平均差值,以改进手术模式。材料与方法研究背景:巴基斯坦拉合尔梅奥医院眼科研究所;拉合尔萨达尔信托眼科医院;眼睛协会,拉合尔,巴基斯坦。研究设计横断面研究。结果共纳入69例患者(男36例,女33例),年龄16 ~ 68岁(平均23.5岁),其中外斜视48例(70%),内斜视21例(30%)。外斜视的偏斜角范围为12 ~ 87棱镜屈光度(PD)(平均44.23±19.20 PD),内斜视的偏斜角范围为10 ~ 104棱镜屈光度(平均47.19±29.10 PD)。角膜光反射测试(Hirschberg测试)与交替棱镜盖测试(APCT)测量的严重偏差偏差角的平均差异显著(p值)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
0.00%
发文量
372
审稿时长
3-8 weeks
期刊介绍: The European Journal of Ophthalmology was founded in 1991 and is issued in print bi-monthly. It publishes only peer-reviewed original research reporting clinical observations and laboratory investigations with clinical relevance focusing on new diagnostic and surgical techniques, instrument and therapy updates, results of clinical trials and research findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信