Cardiac troponin detection in one drop of saliva or urine for 10-minute assessment of acute myocardial infarction.

IF 12.2 2区 材料科学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Xuelian Wu, Zewei Lian, Zhiyu Tan, Yaqun Yu, Tong Ren, Hua Shen, Jie Zhang, Shengli Jiang, Yundai Chen, Meng Su, Nan Cheng
{"title":"Cardiac troponin detection in one drop of saliva or urine for 10-minute assessment of acute myocardial infarction.","authors":"Xuelian Wu, Zewei Lian, Zhiyu Tan, Yaqun Yu, Tong Ren, Hua Shen, Jie Zhang, Shengli Jiang, Yundai Chen, Meng Su, Nan Cheng","doi":"10.1039/d5mh00525f","DOIUrl":null,"url":null,"abstract":"<p><p>Acute myocardial infarction (AMI) can be fatal with sudden death, heart failure, and cardiac rupture. However, it is a challenge to achieve point-of-care testing (POCT) for cardiac troponin T (CTnT), an acute myocardial infarction biomarker, using conventional ELISA because it requires professional expertise and involves time-consuming steps. Herein, we propose a printed immunosensing photonic crystal biochip (PCB), which enables the sensitive, convenient, and non-invasive detection of CTnT. The fluorescence enhancement property of the PCB enables detection of CTnT within 10 minutes, with a limit of detection of 0.25 pg mL<sup>-1</sup>, compared to the conventional ELISA (2.5 h, 30 pg mL<sup>-1</sup>). Owing to the hydrodynamic enrichment of the PCB, 10 μL of sample can be measured, minimizing interference from impurities in body fluids and human sampling errors. We used 100 clinical samples, including serum, saliva, and urine, to verify the reliability of the PCB assay; compared with ELISA, the PCB assay exhibited consistencies of 0.998, 0.999, and 0.999, respectively. Notably, monitoring the saliva of a patient with an AMI history using the PCB assay enables rapid therapeutic intervention within 30 minutes. The PCB was first used for non-invasive body fluid testing to provide reliable results for clinical diagnosis, with the potential to provide AMI health promotion.</p>","PeriodicalId":87,"journal":{"name":"Materials Horizons","volume":" ","pages":""},"PeriodicalIF":12.2000,"publicationDate":"2025-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials Horizons","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1039/d5mh00525f","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Acute myocardial infarction (AMI) can be fatal with sudden death, heart failure, and cardiac rupture. However, it is a challenge to achieve point-of-care testing (POCT) for cardiac troponin T (CTnT), an acute myocardial infarction biomarker, using conventional ELISA because it requires professional expertise and involves time-consuming steps. Herein, we propose a printed immunosensing photonic crystal biochip (PCB), which enables the sensitive, convenient, and non-invasive detection of CTnT. The fluorescence enhancement property of the PCB enables detection of CTnT within 10 minutes, with a limit of detection of 0.25 pg mL-1, compared to the conventional ELISA (2.5 h, 30 pg mL-1). Owing to the hydrodynamic enrichment of the PCB, 10 μL of sample can be measured, minimizing interference from impurities in body fluids and human sampling errors. We used 100 clinical samples, including serum, saliva, and urine, to verify the reliability of the PCB assay; compared with ELISA, the PCB assay exhibited consistencies of 0.998, 0.999, and 0.999, respectively. Notably, monitoring the saliva of a patient with an AMI history using the PCB assay enables rapid therapeutic intervention within 30 minutes. The PCB was first used for non-invasive body fluid testing to provide reliable results for clinical diagnosis, with the potential to provide AMI health promotion.

在一滴唾液或尿液中检测心肌肌钙蛋白10分钟评估急性心肌梗死。
急性心肌梗死(AMI)可能是致命的猝死、心力衰竭和心脏破裂。然而,使用传统的ELISA技术实现心肌肌钙蛋白T (CTnT)(一种急性心肌梗死生物标志物)的即时检测(POCT)是一个挑战,因为它需要专业知识并且涉及耗时的步骤。在此,我们提出了一种印刷免疫传感光子晶体生物芯片(PCB),它可以实现对CTnT的灵敏、方便和无创检测。与传统ELISA (2.5 h, 30 pg mL-1)相比,PCB的荧光增强特性可在10分钟内检测到CTnT,检测限为0.25 pg mL-1。由于PCB的流体动力学富集,可测量10 μL的样品,最大限度地减少了体液杂质的干扰和人为采样误差。我们使用了100个临床样本,包括血清、唾液和尿液,来验证多氯联苯测定的可靠性;与ELISA法比较,PCB法的一致性分别为0.998、0.999和0.999。值得注意的是,使用PCB测定法监测AMI病史患者的唾液,可以在30分钟内进行快速治疗干预。PCB首先用于无创体液检测,为临床诊断提供可靠的结果,具有促进急性心肌梗死健康的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Materials Horizons
Materials Horizons CHEMISTRY, MULTIDISCIPLINARY-MATERIALS SCIENCE, MULTIDISCIPLINARY
CiteScore
18.90
自引率
2.30%
发文量
306
审稿时长
1.3 months
期刊介绍: Materials Horizons is a leading journal in materials science that focuses on publishing exceptionally high-quality and innovative research. The journal prioritizes original research that introduces new concepts or ways of thinking, rather than solely reporting technological advancements. However, groundbreaking articles featuring record-breaking material performance may also be published. To be considered for publication, the work must be of significant interest to our community-spanning readership. Starting from 2021, all articles published in Materials Horizons will be indexed in MEDLINE©. The journal publishes various types of articles, including Communications, Reviews, Opinion pieces, Focus articles, and Comments. It serves as a core journal for researchers from academia, government, and industry across all areas of materials research. Materials Horizons is a Transformative Journal and compliant with Plan S. It has an impact factor of 13.3 and is indexed in MEDLINE.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信