Establishment of ABEI-based direct chemiluminescence immunoassays for PIC, TAT, tPAIC, and TM and their preliminary evaluation in thrombotic diseases†

IF 2.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Honggao Sun, Kun Liu, Jinqiu Fu, Xuehong Li, Lili Qiu, Manna Weng, Yun Zhang, Jiayi Zhang, Ke Huang, Xing Gan, Zhonggang Fang and Hua Pei
{"title":"Establishment of ABEI-based direct chemiluminescence immunoassays for PIC, TAT, tPAIC, and TM and their preliminary evaluation in thrombotic diseases†","authors":"Honggao Sun, Kun Liu, Jinqiu Fu, Xuehong Li, Lili Qiu, Manna Weng, Yun Zhang, Jiayi Zhang, Ke Huang, Xing Gan, Zhonggang Fang and Hua Pei","doi":"10.1039/D5AY00537J","DOIUrl":null,"url":null,"abstract":"<p >Thromboembolism is a leading cause of mortality worldwide. Screening and diagnosis are essential for the prevention and control of thrombotic diseases. This study evaluated four newly developed chemiluminescence assays for the detection of α2-plasmininhibitor-plasmin complex (PIC), thrombin–antithrombin III complex (TAT), tissue plasminogen activator-plasminogen activator inhibitor complex (tPAIC) and thrombomodulin (TM) based on an <em>N</em>-(4-aminobutyl)-<em>N</em>-ethylisoluminol (ABEI)-hydrogen peroxide (H<small><sub>2</sub></small>O<small><sub>2</sub></small>) system. Results demonstrated that the proposed MAGLUMI PIC, TAT, tPAIC and TM tests exhibited good analytical performance and were in good concordance with the SYSMEX system. Compared with the controls, patients with thrombotic diseases exhibited significantly elevated levels of TAT, PIC, TM, and tPAIC in disseminated intravascular coagulation (DIC) and elevated levels of TAT, PIC, and tPAIC in ischemic stroke (IS). Logistic regression analysis and receiver operating characteristic (ROC) curve analysis showed that combined PIC and tPAIC contributed to the best area under the curve (AUC) value of 0.915 (95% confidence interval (CI): 0.859–0.959) for DIC diagnosis. The diagnostic system formed using TAT, PIC, and tPAIC could be used for IS diagnosis with an AUC value of 0.839 (95% CI: 0.762–0.899). Our study demonstrates the good performance of MAGLUMI TAT, PIC, tPAIC and TM CLIA tests, suggesting their potential for thrombotic disease diagnosis, and the combination of these thrombosis markers could provide an enhancement in diagnostic efficacy.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" 26","pages":" 5489-5497"},"PeriodicalIF":2.6000,"publicationDate":"2025-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ay/d5ay00537j","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Thromboembolism is a leading cause of mortality worldwide. Screening and diagnosis are essential for the prevention and control of thrombotic diseases. This study evaluated four newly developed chemiluminescence assays for the detection of α2-plasmininhibitor-plasmin complex (PIC), thrombin–antithrombin III complex (TAT), tissue plasminogen activator-plasminogen activator inhibitor complex (tPAIC) and thrombomodulin (TM) based on an N-(4-aminobutyl)-N-ethylisoluminol (ABEI)-hydrogen peroxide (H2O2) system. Results demonstrated that the proposed MAGLUMI PIC, TAT, tPAIC and TM tests exhibited good analytical performance and were in good concordance with the SYSMEX system. Compared with the controls, patients with thrombotic diseases exhibited significantly elevated levels of TAT, PIC, TM, and tPAIC in disseminated intravascular coagulation (DIC) and elevated levels of TAT, PIC, and tPAIC in ischemic stroke (IS). Logistic regression analysis and receiver operating characteristic (ROC) curve analysis showed that combined PIC and tPAIC contributed to the best area under the curve (AUC) value of 0.915 (95% confidence interval (CI): 0.859–0.959) for DIC diagnosis. The diagnostic system formed using TAT, PIC, and tPAIC could be used for IS diagnosis with an AUC value of 0.839 (95% CI: 0.762–0.899). Our study demonstrates the good performance of MAGLUMI TAT, PIC, tPAIC and TM CLIA tests, suggesting their potential for thrombotic disease diagnosis, and the combination of these thrombosis markers could provide an enhancement in diagnostic efficacy.

Abstract Image

基于abei的PIC、TAT、tpac和TM直接化学发光免疫检测方法的建立及其在血栓性疾病中的初步评价。
血栓栓塞是全世界死亡的主要原因。筛查和诊断对于预防和控制血栓性疾病至关重要。本研究评价了基于N-(4-氨基丁基)-N-乙基异亮醇(ABEI)-过氧化氢(H2O2)体系的四种新建立的检测α2-纤溶酶抑制剂-纤溶酶复合体(PIC)、凝血酶-抗凝血酶III复合体(TAT)、组织纤溶酶原激活物-纤溶酶原激活物抑制剂复合体(tpai)和血栓调节蛋白(TM)的化学发光方法。结果表明,所建立的MAGLUMI PIC、TAT、tpai和TM检测方法具有良好的分析性能,且与SYSMEX系统具有良好的一致性。与对照组相比,血栓性疾病患者弥散性血管内凝血(DIC)中TAT、PIC、TM和tpai水平显著升高,缺血性卒中(IS)中TAT、PIC和tpai水平显著升高。Logistic回归分析和受试者工作特征(ROC)曲线分析显示,PIC和tpai联合诊断DIC的最佳曲线下面积(AUC)值为0.915(95%可信区间(CI): 0.859 ~ 0.959)。TAT、PIC、tpai组成的诊断系统可用于IS诊断,AUC值为0.839 (95% CI: 0.762 ~ 0.899)。我们的研究表明,MAGLUMI TAT、PIC、tpai和TM CLIA检测具有良好的性能,提示它们在血栓性疾病的诊断中具有潜力,这些血栓标志物的联合应用可以提高诊断效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信