ASHIPH Cherenkov counters in the KEDR experiment

IF 1.5 3区 物理与天体物理 Q3 INSTRUMENTS & INSTRUMENTATION
A. Yu. Barnyakov , M. Yu. Barnyakov , V.S. Bobrovnikov , A.R. Buzykaev , A.F. Danilyuk , A.A. Katcin , E.A. Kravchenko , S.A. Kononov , I.A. Kuyanov , V.M. Malyshev , A.P. Onuchin , I.V. Ovtin , K.G. Petrukhin , N.A. Podgornov , O.L. Rezanova
{"title":"ASHIPH Cherenkov counters in the KEDR experiment","authors":"A. Yu. Barnyakov ,&nbsp;M. Yu. Barnyakov ,&nbsp;V.S. Bobrovnikov ,&nbsp;A.R. Buzykaev ,&nbsp;A.F. Danilyuk ,&nbsp;A.A. Katcin ,&nbsp;E.A. Kravchenko ,&nbsp;S.A. Kononov ,&nbsp;I.A. Kuyanov ,&nbsp;V.M. Malyshev ,&nbsp;A.P. Onuchin ,&nbsp;I.V. Ovtin ,&nbsp;K.G. Petrukhin ,&nbsp;N.A. Podgornov ,&nbsp;O.L. Rezanova","doi":"10.1016/j.nima.2025.170739","DOIUrl":null,"url":null,"abstract":"<div><div>The particle identification system ASHIPH (Aerogel, SHIfter, PHotomultiplier) has been working in the KEDR experiment at the VEPP-4M <span><math><mrow><msup><mrow><mi>e</mi></mrow><mrow><mo>+</mo></mrow></msup><msup><mrow><mi>e</mi></mrow><mrow><mo>−</mo></mrow></msup></mrow></math></span> collider (Budker INP, Novosibirsk), without interventions and upgrade, since 2014. The system consists of 160 aerogel Cherenkov counters containing aerogel with refractive index of 1.05. The ASHIPH system provides <span><math><mrow><mi>π</mi><mo>/</mo><mi>K</mi></mrow></math></span> separation in the momentum range from 0.6 to 1.5<!--> <!-->GeV/<span><math><mi>c</mi></math></span>. The status of the system is presented. The long-term stability of aerogel counters in the KEDR experiment is studied. The use of the ASHIPH system in physics analysis is presented as well.</div></div>","PeriodicalId":19359,"journal":{"name":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","volume":"1080 ","pages":"Article 170739"},"PeriodicalIF":1.5000,"publicationDate":"2025-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0168900225005406","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

The particle identification system ASHIPH (Aerogel, SHIfter, PHotomultiplier) has been working in the KEDR experiment at the VEPP-4M e+e collider (Budker INP, Novosibirsk), without interventions and upgrade, since 2014. The system consists of 160 aerogel Cherenkov counters containing aerogel with refractive index of 1.05. The ASHIPH system provides π/K separation in the momentum range from 0.6 to 1.5 GeV/c. The status of the system is presented. The long-term stability of aerogel counters in the KEDR experiment is studied. The use of the ASHIPH system in physics analysis is presented as well.
ashhiph Cherenkov在KEDR实验中反驳道
粒子识别系统ashhiph(气凝胶,SHIfter,光电倍增器)自2014年以来一直在VEPP-4M e+e−对撞机(Budker INP, Novosibirsk)的KEDR实验中工作,没有干预和升级。该系统由160个气凝胶切伦科夫计数器组成,内含折射率为1.05的气凝胶。ashhiph系统在0.6至1.5 GeV/c的动量范围内提供π/K分离。介绍了系统的现状。研究了气凝胶计数器在KEDR实验中的长期稳定性。介绍了ashhiph系统在物理分析中的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.20
自引率
21.40%
发文量
787
审稿时长
1 months
期刊介绍: Section A of Nuclear Instruments and Methods in Physics Research publishes papers on design, manufacturing and performance of scientific instruments with an emphasis on large scale facilities. This includes the development of particle accelerators, ion sources, beam transport systems and target arrangements as well as the use of secondary phenomena such as synchrotron radiation and free electron lasers. It also includes all types of instrumentation for the detection and spectrometry of radiations from high energy processes and nuclear decays, as well as instrumentation for experiments at nuclear reactors. Specialized electronics for nuclear and other types of spectrometry as well as computerization of measurements and control systems in this area also find their place in the A section. Theoretical as well as experimental papers are accepted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信