Diagnostic accuracy of optic disc microvasculature dropout for detecting glaucoma in eyes with high myopia.

IF 3.7 2区 医学 Q1 OPHTHALMOLOGY
Kaiming Ruan,Dan Cheng,Yiyi Wang,Weihua Ni,Hongling Chen,Hao Chen,Shiqi Sun,Sen Lin,Aizhu Tao,Yilei Shao,Yufeng Ye,Meixiao Shen
{"title":"Diagnostic accuracy of optic disc microvasculature dropout for detecting glaucoma in eyes with high myopia.","authors":"Kaiming Ruan,Dan Cheng,Yiyi Wang,Weihua Ni,Hongling Chen,Hao Chen,Shiqi Sun,Sen Lin,Aizhu Tao,Yilei Shao,Yufeng Ye,Meixiao Shen","doi":"10.1136/bjo-2025-327237","DOIUrl":null,"url":null,"abstract":"PURPOSE\r\nTo characterise microvasculature dropout (MvD) and assess the diagnostic efficacy of MvD in detecting glaucoma in eyes with high myopia (HM).\r\n\r\nMETHODS\r\nThis prospective cross-sectional study included 107 participants divided into HM group and HM with glaucoma group. Structural and vascular parameters were quantified using swept-source optical coherence tomography (SS-OCT) and OCT angiography (OCTA), including the peripapillary retinal nerve fibre layer (pRNFL), macular ganglion cell inner plexiform layer (mGCIPL), superficial capillary plexus, radial peripapillary capillaries, optic disc microvasculature dropout (MvD-D) and peripapillary microvasculature dropout. Receiver operating characteristic curves were employed to evaluate the diagnostic performance of each parameter. Univariate and multivariate linear regression analyses were conducted to examine associations between these parameters and mean deviations of the visual field test.\r\n\r\nRESULTS\r\nMvD-D outperformed all other structural and vascular metrics, achieving the highest area under the curve of 0.95. In multivariate regression analysis, MvD-D was identified as an independent factor associated with visual field loss (β=-0.42, p=0.02).\r\n\r\nCONCLUSIONS\r\nMvD-D demonstrates superior diagnostic performance compared with traditional structural markers such as pRNFL and mGCIPL in identifying glaucoma in highly myopic patients. Integrating MvD-D into routine clinical practice may provide a sightful value in detecting glaucoma with myopic discs.","PeriodicalId":9313,"journal":{"name":"British Journal of Ophthalmology","volume":"111 1","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2025-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/bjo-2025-327237","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

PURPOSE To characterise microvasculature dropout (MvD) and assess the diagnostic efficacy of MvD in detecting glaucoma in eyes with high myopia (HM). METHODS This prospective cross-sectional study included 107 participants divided into HM group and HM with glaucoma group. Structural and vascular parameters were quantified using swept-source optical coherence tomography (SS-OCT) and OCT angiography (OCTA), including the peripapillary retinal nerve fibre layer (pRNFL), macular ganglion cell inner plexiform layer (mGCIPL), superficial capillary plexus, radial peripapillary capillaries, optic disc microvasculature dropout (MvD-D) and peripapillary microvasculature dropout. Receiver operating characteristic curves were employed to evaluate the diagnostic performance of each parameter. Univariate and multivariate linear regression analyses were conducted to examine associations between these parameters and mean deviations of the visual field test. RESULTS MvD-D outperformed all other structural and vascular metrics, achieving the highest area under the curve of 0.95. In multivariate regression analysis, MvD-D was identified as an independent factor associated with visual field loss (β=-0.42, p=0.02). CONCLUSIONS MvD-D demonstrates superior diagnostic performance compared with traditional structural markers such as pRNFL and mGCIPL in identifying glaucoma in highly myopic patients. Integrating MvD-D into routine clinical practice may provide a sightful value in detecting glaucoma with myopic discs.
视盘微血管脱落对高度近视眼青光眼的诊断准确性。
目的探讨微血管脱落(MvD)的特征,评价微血管脱落(MvD)对高度近视(HM)青光眼的诊断价值。方法前瞻性横断面研究将107例患者分为HM组和HM合并青光眼组。采用扫源光学相干断层扫描(SS-OCT)和OCT血管造影(OCTA)对结构和血管参数进行量化,包括乳头周围视网膜神经纤维层(pRNFL)、黄斑神经节细胞内丛状层(mGCIPL)、浅表毛细血管丛、放射状乳头周围毛细血管、视盘微血管脱落(MvD-D)和乳头周围微血管脱落。采用受试者工作特征曲线评价各参数的诊断性能。进行单因素和多因素线性回归分析,以检验这些参数与视野测试的平均偏差之间的关系。结果smvd - d优于其他结构和血管指标,曲线下面积最高,为0.95。在多元回归分析中,MvD-D被确定为与视野丧失相关的独立因素(β=-0.42, p=0.02)。结论smvd - d对高度近视青光眼的诊断效果优于pRNFL、mGCIPL等传统结构标记。将MvD-D纳入常规临床实践,对发现伴有近视盘的青光眼具有一定的视觉价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
10.30
自引率
2.40%
发文量
213
审稿时长
3-6 weeks
期刊介绍: The British Journal of Ophthalmology (BJO) is an international peer-reviewed journal for ophthalmologists and visual science specialists. BJO publishes clinical investigations, clinical observations, and clinically relevant laboratory investigations related to ophthalmology. It also provides major reviews and also publishes manuscripts covering regional issues in a global context.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信