Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation.

IF 1.9 4区 医学 Q3 OPHTHALMOLOGY
Journal of Ophthalmology Pub Date : 2025-06-12 eCollection Date: 2025-01-01 DOI:10.1155/joph/6959314
Beltrán-Murcia J, Álvarez-Rementería Capelo L, Blázquez-Sánchez V
{"title":"Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation.","authors":"Beltrán-Murcia J, Álvarez-Rementería Capelo L, Blázquez-Sánchez V","doi":"10.1155/joph/6959314","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> The correlations between different parameters and the positioning of the EVO ICL were analyzed. Significant correlations were observed, highlighting the relationship between the endothelium and the anterior surface of the phakic ICL lens. However, it is important to note that GAP is only a postoperative measure and cannot be used to directly define the correct positioning of the EVO ICL. The study emphasizes these correlations, without drawing conclusions regarding the causal relationships between the parameters. <b>Methods:</b> In this retrospective, observational, transversal analytic study, patients who underwent refractive surgery with implanted EVO ICL pIOL were analyzed. The distance between corneal endothelium and anterior surface of ICL (GAP) was measured postoperatively at 1 week and 1 month using ANTERION AS-OCT. <b>Results:</b> 35 eyes of 35 patients were analyzed. The mean GAP values at 1 week and 1 month were 2.5 ± 0.2 mm and 2.6 ± 0.2 mm, respectively (<i>p</i> = 0.002), increasing its value. The GAP value correlated positively with preoperative anterior chamber volume, white-to-white, lens vault, spur-spur distance, anterior chamber angle distance, and anterior chamber angles values. <b>Conclusions:</b> The correlations between GAP and pre- and postoperative variables highlight its relationship with anterior segment anatomy after EVO ICL implantation. However, as a postoperative measurement, GAP does not determine the correct positioning of the lens.</p>","PeriodicalId":16674,"journal":{"name":"Journal of Ophthalmology","volume":"2025 ","pages":"6959314"},"PeriodicalIF":1.9000,"publicationDate":"2025-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12178738/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/joph/6959314","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The correlations between different parameters and the positioning of the EVO ICL were analyzed. Significant correlations were observed, highlighting the relationship between the endothelium and the anterior surface of the phakic ICL lens. However, it is important to note that GAP is only a postoperative measure and cannot be used to directly define the correct positioning of the EVO ICL. The study emphasizes these correlations, without drawing conclusions regarding the causal relationships between the parameters. Methods: In this retrospective, observational, transversal analytic study, patients who underwent refractive surgery with implanted EVO ICL pIOL were analyzed. The distance between corneal endothelium and anterior surface of ICL (GAP) was measured postoperatively at 1 week and 1 month using ANTERION AS-OCT. Results: 35 eyes of 35 patients were analyzed. The mean GAP values at 1 week and 1 month were 2.5 ± 0.2 mm and 2.6 ± 0.2 mm, respectively (p = 0.002), increasing its value. The GAP value correlated positively with preoperative anterior chamber volume, white-to-white, lens vault, spur-spur distance, anterior chamber angle distance, and anterior chamber angles values. Conclusions: The correlations between GAP and pre- and postoperative variables highlight its relationship with anterior segment anatomy after EVO ICL implantation. However, as a postoperative measurement, GAP does not determine the correct positioning of the lens.

EVO ICL晶状体植入术中生物特征参数与内皮距离的相关性研究。
目的:分析不同参数与EVO ICL定位的相关性。我们观察到显著的相关性,强调了内皮细胞与晶状体晶状体前表面的关系。然而,需要注意的是,GAP仅是术后测量,不能直接用于确定EVO ICL的正确定位。该研究强调了这些相关性,但没有就参数之间的因果关系得出结论。方法:回顾性、观察性、横向分析性研究,对接受屈光手术植入EVO ICL pIOL的患者进行分析。术后1周和1个月采用ANTERION AS-OCT测量角膜内皮与ICL前表面之间的距离(GAP)。结果:对35例患者35只眼进行分析。1周和1个月的GAP平均值分别为2.5±0.2 mm和2.6±0.2 mm (p = 0.002),增加了GAP值。GAP值与术前前房容积、白对白、晶状体穹窿、骨刺距、前房角距、前房角值呈正相关。结论:GAP与EVO ICL植入术前、术后变量的相关性突出了其与前节解剖结构的关系。然而,作为术后测量,GAP不能确定晶状体的正确定位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Ophthalmology
Journal of Ophthalmology MEDICINE, RESEARCH & EXPERIMENTAL-OPHTHALMOLOGY
CiteScore
4.30
自引率
5.30%
发文量
194
审稿时长
6-12 weeks
期刊介绍: Journal of Ophthalmology is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies related to the anatomy, physiology and diseases of the eye. Submissions should focus on new diagnostic and surgical techniques, instrument and therapy updates, as well as clinical trials and research findings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信