Correlation of early contrast-enhanced ultrasound parameters with postoperative graft function and at six months after kidney transplantation.

IF 1.6 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Ultrasound International Open Pub Date : 2024-11-06 eCollection Date: 2024-01-01 DOI:10.1055/a-2435-2176
Tina Taut, Felix Kurz, Heinz-Peter Schlemmer, Clara Meinzer, Christoph Mahler, Claudius Speer, Louise Benning, Daniel Göth, Christian Nusshag, Claudia Sommerer, Matthias Schaier, Martin Zeier, Christian Morath, Florian Kälble
{"title":"Correlation of early contrast-enhanced ultrasound parameters with postoperative graft function and at six months after kidney transplantation.","authors":"Tina Taut, Felix Kurz, Heinz-Peter Schlemmer, Clara Meinzer, Christoph Mahler, Claudius Speer, Louise Benning, Daniel Göth, Christian Nusshag, Claudia Sommerer, Matthias Schaier, Martin Zeier, Christian Morath, Florian Kälble","doi":"10.1055/a-2435-2176","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose</b> We analyzed which contrast-enhanced ultrasound (CEUS) parameters are associated with reduced kidney function in the early postoperative period and are prognostic for kidney function six months after transplantation. <b>Materials and Methods</b> This prospective observational study included 74 patients in whom quantitative CEUS analysis and Doppler ultrasound were performed early after kidney transplantation (10±6 days). For each region of interest (ROI) the time-to-peak intensity (TTP) and the respective delta between ROIs within interlobar artery, cortex, and medulla were compared. Results were correlated with kidney function at the time of imaging and six months later. <b>Results</b> Patients with an eGFR<30 ml/min at the time of investigation had significantly slower cortical enhancement with a longer cortical TTP (cTTP: 16.1±0.9 vs. 11.7±0.7 sec, p<0.001), as well as a significant delay between the arterial and cortical phases (c-a), as shown in longer ∆TTP (c-a): 8.2±0.9 vs. 4.2 ± 0.5 sec, p<0.001. There was a significant negative correlation between cTTP and eGFR with a correlation coefficient of -0.37 (p<0.001), as well as between ∆TTP (c-a) and eGFR with a correlation coefficient of -0.40 (p<0.001). Reduced kidney function after 6 months correlated significantly with the findings of the initial CEUS examination (p=0.005, correlation coefficient -0.39). <b>Conclusion</b> CEUS revealed significant differences in temporal enhancement dynamics in patients with reduced kidney function after transplantation. Quantitative CEUS might therefore be able to depict graft function regarding microvascular damage and be of prognostic value regarding long-term renal outcomes.</p>","PeriodicalId":44852,"journal":{"name":"Ultrasound International Open","volume":"10 ","pages":"a24352176"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12164733/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound International Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-2435-2176","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose We analyzed which contrast-enhanced ultrasound (CEUS) parameters are associated with reduced kidney function in the early postoperative period and are prognostic for kidney function six months after transplantation. Materials and Methods This prospective observational study included 74 patients in whom quantitative CEUS analysis and Doppler ultrasound were performed early after kidney transplantation (10±6 days). For each region of interest (ROI) the time-to-peak intensity (TTP) and the respective delta between ROIs within interlobar artery, cortex, and medulla were compared. Results were correlated with kidney function at the time of imaging and six months later. Results Patients with an eGFR<30 ml/min at the time of investigation had significantly slower cortical enhancement with a longer cortical TTP (cTTP: 16.1±0.9 vs. 11.7±0.7 sec, p<0.001), as well as a significant delay between the arterial and cortical phases (c-a), as shown in longer ∆TTP (c-a): 8.2±0.9 vs. 4.2 ± 0.5 sec, p<0.001. There was a significant negative correlation between cTTP and eGFR with a correlation coefficient of -0.37 (p<0.001), as well as between ∆TTP (c-a) and eGFR with a correlation coefficient of -0.40 (p<0.001). Reduced kidney function after 6 months correlated significantly with the findings of the initial CEUS examination (p=0.005, correlation coefficient -0.39). Conclusion CEUS revealed significant differences in temporal enhancement dynamics in patients with reduced kidney function after transplantation. Quantitative CEUS might therefore be able to depict graft function regarding microvascular damage and be of prognostic value regarding long-term renal outcomes.

早期超声造影参数与肾移植术后功能及肾移植术后6个月的相关性。
目的分析对比增强超声(CEUS)参数与移植术后早期肾功能下降的关系以及对移植后6个月肾功能的预后。材料与方法本前瞻性观察研究纳入74例肾移植术后早期(10±6天)行定量超声造影和多普勒超声检查的患者。对于每个感兴趣区域(ROI),比较叶间动脉、皮层和髓质的ROI之间的峰值时间强度(TTP)和各自的delta。结果与成像时和6个月后的肾功能相关。结论超声造影显示移植后肾功能下降患者的时间增强动态有显著差异。因此,定量超声可能能够描述移植物微血管损伤的功能,并对长期肾脏预后具有预后价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ultrasound International Open
Ultrasound International Open RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
0.00%
发文量
7
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信