Yunus Emre Senturk, Ahmet Peker, Hande Ozen Atalay, Ayse Altintas, Ali Yusuf Oner
{"title":"Diagnostic Accuracy of Isotropic FLAIR-T2* Fusion Imaging for Central Vein Sign Detection in Multiple Sclerosis: a Comparative Study at 1.5 T and 3 T.","authors":"Yunus Emre Senturk, Ahmet Peker, Hande Ozen Atalay, Ayse Altintas, Ali Yusuf Oner","doi":"10.1007/s00062-025-01531-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The central vein sign (CVS) is a promising imaging biomarker for multiple sclerosis (MS) diagnosis. While isotropic T2* at 3 T and 7 T has demonstrated high diagnostic performance, its utility at 1.5 T remains unclear. This study evaluates the performance of unenhanced FLAIR-T2* fusion at 1.5 T compared to 3 T in MS participants.</p><p><strong>Methods: </strong>This prospective observational study included 20 MS patients and 20 control subjects. Each participant underwent unenhanced isotropic Epi-T2* and isotropic FLAIR (0.8 mm voxel size) at both 1.5 T and 3 T. Subsequently, the derived isotropic T2* and FLAIR were combined to create the final FLAIR-T2* fusion in both magnetic field strengths. Two independent raters assessed the CVS status of white matter (WM) lesions using NAIMS criteria. WM lesions were classified as CVS+ or CVS-, and two methods-select-n* and CVS+ proportion-were applied. Sensitivity and specificity were computed, and CVS performance was compared across WM lesion locations.</p><p><strong>Results: </strong>Among eligible WM lesions (MS: 258; controls: 255), the mean CVS+ lesion proportion per participant was 66.9 ± 15.4% for 1.5 T FLAIR-T2* and 77.0 ± 13.6% for 3 T FLAIR-T2* (p < 0.01). At a 40% threshold, 1.5 T FLAIR-T2* achieved 90% sensitivity and 95% specificity, while 3 T FLAIR-T2* achieved 100% sensitivity and 95% specificity. The Select-6* method resulted in only one MS patient being misclassified at both field strengths. 3 T FLAIR-T2* detected more CVS+ lesions in deep WM (87.5% vs. 57.1%, p = 0.05).</p><p><strong>Conclusion: </strong>1.5 T FLAIR-T2* fusion demonstrates high performance in CVS assessment, although slightly outperformed by 3 T FLAIR-T2*. The select-6* method may enhance 1.5 T performance, supporting its feasibility for CVS evaluation.</p>","PeriodicalId":10391,"journal":{"name":"Clinical Neuroradiology","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00062-025-01531-6","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The central vein sign (CVS) is a promising imaging biomarker for multiple sclerosis (MS) diagnosis. While isotropic T2* at 3 T and 7 T has demonstrated high diagnostic performance, its utility at 1.5 T remains unclear. This study evaluates the performance of unenhanced FLAIR-T2* fusion at 1.5 T compared to 3 T in MS participants.
Methods: This prospective observational study included 20 MS patients and 20 control subjects. Each participant underwent unenhanced isotropic Epi-T2* and isotropic FLAIR (0.8 mm voxel size) at both 1.5 T and 3 T. Subsequently, the derived isotropic T2* and FLAIR were combined to create the final FLAIR-T2* fusion in both magnetic field strengths. Two independent raters assessed the CVS status of white matter (WM) lesions using NAIMS criteria. WM lesions were classified as CVS+ or CVS-, and two methods-select-n* and CVS+ proportion-were applied. Sensitivity and specificity were computed, and CVS performance was compared across WM lesion locations.
Results: Among eligible WM lesions (MS: 258; controls: 255), the mean CVS+ lesion proportion per participant was 66.9 ± 15.4% for 1.5 T FLAIR-T2* and 77.0 ± 13.6% for 3 T FLAIR-T2* (p < 0.01). At a 40% threshold, 1.5 T FLAIR-T2* achieved 90% sensitivity and 95% specificity, while 3 T FLAIR-T2* achieved 100% sensitivity and 95% specificity. The Select-6* method resulted in only one MS patient being misclassified at both field strengths. 3 T FLAIR-T2* detected more CVS+ lesions in deep WM (87.5% vs. 57.1%, p = 0.05).
Conclusion: 1.5 T FLAIR-T2* fusion demonstrates high performance in CVS assessment, although slightly outperformed by 3 T FLAIR-T2*. The select-6* method may enhance 1.5 T performance, supporting its feasibility for CVS evaluation.
期刊介绍:
Clinical Neuroradiology provides current information, original contributions, and reviews in the field of neuroradiology. An interdisciplinary approach is accomplished by diagnostic and therapeutic contributions related to associated subjects.
The international coverage and relevance of the journal is underlined by its being the official journal of the German, Swiss, and Austrian Societies of Neuroradiology.