Universal design of a system for liquid–liquid microextraction: green determination of nitrate in vegetable and water samples by automated magnetic stirring-assisted dispersive liquid–liquid microextraction

IF 2.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Jana Šandrejová, Andrea Gajdošová, Rastislav Serbin and Ioseph Balogh
{"title":"Universal design of a system for liquid–liquid microextraction: green determination of nitrate in vegetable and water samples by automated magnetic stirring-assisted dispersive liquid–liquid microextraction","authors":"Jana Šandrejová, Andrea Gajdošová, Rastislav Serbin and Ioseph Balogh","doi":"10.1039/D5AY00316D","DOIUrl":null,"url":null,"abstract":"<p >This article highlights a new approach for liquid–liquid microextraction, which takes into account the possibility of using one flow-based system for various automated microextraction modes. This design for the microextraction process in combination with an optical probe was proposed and successfully tested for dispersive liquid–liquid microextraction (DLLME), air-assisted dispersive liquid–liquid microextraction (AA-DLLME) and magnetic stirring-assisted dispersive liquid–liquid microextraction (MSA-DLLME) of nitrate. The results showed that the proposed system is simple and enables an easy change of the operation protocol. The system was applied to the determination of NO<small><sub>3</sub></small><small><sup>−</sup></small> in the form of an ion associate with the malachite green reagent. Under optimized conditions, the best sensitivity of determination was achieved by MSA-DLLME. The calibration graph was linear over the concentration range of 0.2–10 mg L<small><sup>−1</sup></small> NO<small><sub>3</sub></small><small><sup>−</sup></small>. The LOD was 0.008 mg L<small><sup>−1</sup></small> NO<small><sub>3</sub></small><small><sup>−</sup></small>. The procedure was applied to the determination of nitrate in vegetable and water samples. The applied procedure was compared with ion chromatography approaches and evaluated using metrics, including the Analytical Greenness Metric Approach (AGREE) for greenness, the most current Blue Applicability Grade Index (BAGI) for blueness, and the more inclusive RGB 12 algorithm for whiteness assessment. The evaluation shows high overall scores for the presented procedure.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" 26","pages":" 5383-5391"},"PeriodicalIF":2.6000,"publicationDate":"2025-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ay/d5ay00316d","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This article highlights a new approach for liquid–liquid microextraction, which takes into account the possibility of using one flow-based system for various automated microextraction modes. This design for the microextraction process in combination with an optical probe was proposed and successfully tested for dispersive liquid–liquid microextraction (DLLME), air-assisted dispersive liquid–liquid microextraction (AA-DLLME) and magnetic stirring-assisted dispersive liquid–liquid microextraction (MSA-DLLME) of nitrate. The results showed that the proposed system is simple and enables an easy change of the operation protocol. The system was applied to the determination of NO3 in the form of an ion associate with the malachite green reagent. Under optimized conditions, the best sensitivity of determination was achieved by MSA-DLLME. The calibration graph was linear over the concentration range of 0.2–10 mg L−1 NO3. The LOD was 0.008 mg L−1 NO3. The procedure was applied to the determination of nitrate in vegetable and water samples. The applied procedure was compared with ion chromatography approaches and evaluated using metrics, including the Analytical Greenness Metric Approach (AGREE) for greenness, the most current Blue Applicability Grade Index (BAGI) for blueness, and the more inclusive RGB 12 algorithm for whiteness assessment. The evaluation shows high overall scores for the presented procedure.

Abstract Image

液液微萃取系统的通用设计:自动磁搅拌辅助分散液液微萃取法测定蔬菜和水样中的硝酸盐。
本文重点介绍了一种液液微萃取的新方法,该方法考虑了使用一种基于流的系统进行各种自动化微萃取模式的可能性。提出了结合光学探针的微萃取工艺设计,并对硝酸盐的分散液-液微萃取(DLLME)、空气辅助分散液-液微萃取(AA-DLLME)和磁搅拌辅助分散液-液微萃取(MSA-DLLME)进行了成功的测试。结果表明,该系统结构简单,操作协议易于更改。将该体系应用于孔雀石绿试剂中以离子形式伴生的NO3-的测定。在优化条件下,MSA-DLLME测定灵敏度最高。在0.2 ~ 10 mg L-1 NO3-浓度范围内,标定曲线呈线性关系。LOD为0.008 mg L-1 NO3-。本方法适用于蔬菜和水样中硝酸盐的测定。将应用程序与离子色谱法进行比较,并使用指标进行评估,包括用于绿色的分析绿色度量方法(AGREE),用于蓝色的最新蓝色适用性等级指数(BAGI),以及用于白度评估的更具包容性的RGB 12算法。评估显示,所提出的程序的总体得分很高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信