Assessment of Retention and Penetration Depth of Different Pit and Fissure Sealants: An In-vitro Study.

IF 0.7 Q4 PHARMACOLOGY & PHARMACY
Journal of pharmacy & bioallied sciences Pub Date : 2025-05-01 Epub Date: 2025-04-29 DOI:10.4103/jpbs.jpbs_458_25
Shraddha S Mane, Kanchan Sharma, Richa Pathak, Anisha Luthra, Ritika Gupta, Sameer Ahmed Khan, Subhangi Panda
{"title":"Assessment of Retention and Penetration Depth of Different Pit and Fissure Sealants: An <i>In-vitro</i> Study.","authors":"Shraddha S Mane, Kanchan Sharma, Richa Pathak, Anisha Luthra, Ritika Gupta, Sameer Ahmed Khan, Subhangi Panda","doi":"10.4103/jpbs.jpbs_458_25","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This <i>in-vitro</i> study aims to access the extent of penetration and retention of different sealants in deciduous molars.</p><p><strong>Materials and methods: </strong>Thirty extracted deciduous molars were split into three groups according to the kind of sealants applied. The specimens were divided into the equal numbers after acid etching and sealant application in Group 1: Conventional sealant (Fuji VII GIC, GC Corporation, Tokyo, Japan), Group 2: Colored resin-based-fluoride fissure sealant (Delton FS+ Dentsply, Germany), and Group 3: Nano-silver-reinforced fissure sealant (Kids-e-dental LLP, India) was done. Prepared samples were thermocycle and examined for retention using Simonsen's criterion. Further these samples were coated with nail varnish and soaked in methylene blue solution (1%) for a day and cleaned with distilled water. Buccolingual sectioning of prepared samples was done to examined under a stereomicroscope (SEM) at a magnification of 10X and score by trained examiner based on the sealant penetration depth criteria MLC Fracasso in millimeters. The Non-Parametric Kruskal Wallis H test was used to analyses all the data. 100% retention was found in group 3 followed by group 2 then 1.</p><p><strong>Result and conclusion: </strong>Frequency sealant penetration depth comparison was found significant difference between the groups. Nano-silver-reinforced sealant represented improved retention and penetration as related to the resin-based-fluoride fissure sealant and conventional sealants.</p>","PeriodicalId":94339,"journal":{"name":"Journal of pharmacy & bioallied sciences","volume":"17 Suppl 1","pages":"S718-S720"},"PeriodicalIF":0.7000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12156643/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmacy & bioallied sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jpbs.jpbs_458_25","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/4/29 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: This in-vitro study aims to access the extent of penetration and retention of different sealants in deciduous molars.

Materials and methods: Thirty extracted deciduous molars were split into three groups according to the kind of sealants applied. The specimens were divided into the equal numbers after acid etching and sealant application in Group 1: Conventional sealant (Fuji VII GIC, GC Corporation, Tokyo, Japan), Group 2: Colored resin-based-fluoride fissure sealant (Delton FS+ Dentsply, Germany), and Group 3: Nano-silver-reinforced fissure sealant (Kids-e-dental LLP, India) was done. Prepared samples were thermocycle and examined for retention using Simonsen's criterion. Further these samples were coated with nail varnish and soaked in methylene blue solution (1%) for a day and cleaned with distilled water. Buccolingual sectioning of prepared samples was done to examined under a stereomicroscope (SEM) at a magnification of 10X and score by trained examiner based on the sealant penetration depth criteria MLC Fracasso in millimeters. The Non-Parametric Kruskal Wallis H test was used to analyses all the data. 100% retention was found in group 3 followed by group 2 then 1.

Result and conclusion: Frequency sealant penetration depth comparison was found significant difference between the groups. Nano-silver-reinforced sealant represented improved retention and penetration as related to the resin-based-fluoride fissure sealant and conventional sealants.

不同牙槽和牙缝封闭剂的固位和渗透深度评估:一项体外研究。
目的:研究不同类型牙釉质牙釉质牙釉质牙釉质牙釉质牙釉质牙釉质牙釉质牙釉质牙釉质牙釉质牙釉质牙釉质牙釉质牙釉质牙釉质牙釉质的牙釉质。材料与方法:将30颗摘出的乳牙按所使用的封闭剂种类分为3组。在酸蚀和使用密封胶后,将标本分成等号,第1组:常规密封胶(Fuji VII GIC, GC Corporation, Tokyo, Japan),第2组:彩色树脂基氟化物裂缝密封胶(Delton FS+ Dentsply, Germany),第3组:纳米银增强裂缝密封胶(Kids-e-dental LLP, India)。制备的样品进行热循环,并使用西蒙森准则检查保留。此外,这些样品涂上指甲油,在亚甲基蓝溶液(1%)中浸泡一天,并用蒸馏水清洗。在10倍放大的立体显微镜(SEM)下对制备的样品进行舌部切片检查,并由训练有素的审查员根据密封胶穿透深度标准MLC Fracasso以毫米为单位进行评分。采用非参数Kruskal Wallis H检验对所有数据进行分析。第3组保留率为100%,其次是第2组,然后是第1组。结果与结论:两组间频率密封胶渗透深度比较差异有统计学意义。纳米银增强密封胶与树脂基氟裂缝密封胶和常规密封胶相比,具有更好的滞留性和渗透性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信