Raul G Nogueira, Seán Fitzgerald, Miquel Murillo Artigues, Akorede Rei Adedeji, Liam Mullins, John Thornton
{"title":"Impact of next-generation delivery assist catheters and crossing strategy on reperfusion success in aspiration thrombectomy.","authors":"Raul G Nogueira, Seán Fitzgerald, Miquel Murillo Artigues, Akorede Rei Adedeji, Liam Mullins, John Thornton","doi":"10.1177/15910199251349672","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundIn mechanical thrombectomy procedures, physicians are often forced to cross the clot to get more support in tortuous anatomy. Stentriever procedures always require traversing the clot. Novel delivery assist catheters with a tapered distal tip have been developed to aid aspiration catheter delivery. This study compares a novel delivery assist catheter to conventional support strategies in terms of reperfusion and distal embolization. The impact of remaining proximal versus entering the clot is also investigated, as is the impact of incorporating a Superbore 088 catheter.MethodsSoft, medium, and stiff ovine blood clots were used to form ICA/M1 occlusions in an in-vitro thrombectomy model. Two approaches were tested: navigating the aspiration catheter with and without crossing/entering the clot with support devices. Six setups were tested: Millipede<sup>88</sup> + Zipline<sup>88</sup>, Millipede<sup>88</sup> + Millipede<sup>70</sup> + Zipline<sup>70</sup>, Millipede<sup>70</sup> + Zipline<sup>70</sup>, SOFIA Plus + 021 Microcatheter, SOFIA Plus + 3MAX, SOFIA Plus + 021 Microcatheter + Stentriever. Each setup was tested nine times totaling 72 tests. Revascularization endpoints were First-Pass-Effect (FPE), final complete revascularization, and distal embolization.ResultsAvoiding clot entry was associated with higher FPE rates, improved final revascularization, and fewer distal emboli. Using a 3MAX as a microcatheter and crossing the clot resulted in more distal emboli than a standard 021 microcatheter or stentriever procedure. Millipede<sup>88</sup> + Zipline<sup>88</sup> configuration achieved the highest FPE (67%) when the clot was not crossed (vs. 56% with clot entry). Both 070 aspiration catheters had the same FPE rate (33%) but using Millipede<sup>88</sup> for flow control with Millipede<sup>70</sup> improved the FPE rate (44%). Of the conventional techniques, SOFIA Plus + 021 Microcatheter + Stentriever was associated with the highest FPE rate (44%).ConclusionsRemaining proximal to the clot is advantageous. Next-generation delivery catheters, like Zipline, may enhance catheter delivery without increasing embolization risk. Using larger internal catheters, such as 3MAX, leads to higher rates of emboli when crossing the clot.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"15910199251349672"},"PeriodicalIF":1.5000,"publicationDate":"2025-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12170553/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199251349672","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
BackgroundIn mechanical thrombectomy procedures, physicians are often forced to cross the clot to get more support in tortuous anatomy. Stentriever procedures always require traversing the clot. Novel delivery assist catheters with a tapered distal tip have been developed to aid aspiration catheter delivery. This study compares a novel delivery assist catheter to conventional support strategies in terms of reperfusion and distal embolization. The impact of remaining proximal versus entering the clot is also investigated, as is the impact of incorporating a Superbore 088 catheter.MethodsSoft, medium, and stiff ovine blood clots were used to form ICA/M1 occlusions in an in-vitro thrombectomy model. Two approaches were tested: navigating the aspiration catheter with and without crossing/entering the clot with support devices. Six setups were tested: Millipede88 + Zipline88, Millipede88 + Millipede70 + Zipline70, Millipede70 + Zipline70, SOFIA Plus + 021 Microcatheter, SOFIA Plus + 3MAX, SOFIA Plus + 021 Microcatheter + Stentriever. Each setup was tested nine times totaling 72 tests. Revascularization endpoints were First-Pass-Effect (FPE), final complete revascularization, and distal embolization.ResultsAvoiding clot entry was associated with higher FPE rates, improved final revascularization, and fewer distal emboli. Using a 3MAX as a microcatheter and crossing the clot resulted in more distal emboli than a standard 021 microcatheter or stentriever procedure. Millipede88 + Zipline88 configuration achieved the highest FPE (67%) when the clot was not crossed (vs. 56% with clot entry). Both 070 aspiration catheters had the same FPE rate (33%) but using Millipede88 for flow control with Millipede70 improved the FPE rate (44%). Of the conventional techniques, SOFIA Plus + 021 Microcatheter + Stentriever was associated with the highest FPE rate (44%).ConclusionsRemaining proximal to the clot is advantageous. Next-generation delivery catheters, like Zipline, may enhance catheter delivery without increasing embolization risk. Using larger internal catheters, such as 3MAX, leads to higher rates of emboli when crossing the clot.
期刊介绍:
Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...