Comparative analysis of novel damping capacity analysis devices for assessing implant stability in clinical practice.

IF 3.2 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Su-Bin Hong, Bo-Ah Lee, Woo-Ri Lee, Jung-Seok Lee, Young-Taek Kim
{"title":"Comparative analysis of novel damping capacity analysis devices for assessing implant stability in clinical practice.","authors":"Su-Bin Hong, Bo-Ah Lee, Woo-Ri Lee, Jung-Seok Lee, Young-Taek Kim","doi":"10.5051/jpis.2404680234","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Implant stability testing is crucial for verifying osseointegration before prosthetic loading. Several methods have been developed to assess osseointegration. Among these, damping capacity analysis (DCA) devices offer a user-friendly and non-invasive approach. In this study, we evaluated the accuracy and reliability of newly available DCA devices in assessing dental implant stability.</p><p><strong>Methods: </strong>This study included 58 implants from 37 patients over a 1-month period. Three measurements per implant were obtained with healing abutments in place, following the manufacturers' guidelines, using the DCA-P (Periotest M, Medizintechnik Gulden), DCA-A (Anycheck, Neobiotech), and DCA-T (The Trust, Dentium) devices. Factors such as healing abutment height, time since placement, bone grafting, fixture diameter, and fixture length were evaluated. Accuracy was assessed using DCA-P as the reference, and reproducibility was statistically analyzed using 3 measurements per implant. Statistical analyses were performed with SPSS Statistics 23.0 (IBM Corp.).</p><p><strong>Results: </strong>All implants that passed the stability tests using DCA devices were restored with definitive prostheses and showed no signs of early failure. The DCA-A value demonstrated a very strong correlation with the DCA-P value (DCAV-P), whereas the DCA-T value exhibited only a moderate correlation with DCAV-P. DCA-P also showed the highest reliability, followed by DCA-A and then DCA-T. The reliability of DCA-A and DCA-T was not significantly affected by any of the assessed factors; in contrast, DCA-P's reliability was significantly influenced by arch location and specific quadrant position.</p><p><strong>Conclusions: </strong>With DCA-P as the reference, DCA-A demonstrated superior accuracy compared to DCA-T. Although DCA-P exhibited the highest reliability, its performance was significantly affected by the positional factors of the target implant.</p>","PeriodicalId":48795,"journal":{"name":"Journal of Periodontal and Implant Science","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-04-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Periodontal and Implant Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5051/jpis.2404680234","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Implant stability testing is crucial for verifying osseointegration before prosthetic loading. Several methods have been developed to assess osseointegration. Among these, damping capacity analysis (DCA) devices offer a user-friendly and non-invasive approach. In this study, we evaluated the accuracy and reliability of newly available DCA devices in assessing dental implant stability.

Methods: This study included 58 implants from 37 patients over a 1-month period. Three measurements per implant were obtained with healing abutments in place, following the manufacturers' guidelines, using the DCA-P (Periotest M, Medizintechnik Gulden), DCA-A (Anycheck, Neobiotech), and DCA-T (The Trust, Dentium) devices. Factors such as healing abutment height, time since placement, bone grafting, fixture diameter, and fixture length were evaluated. Accuracy was assessed using DCA-P as the reference, and reproducibility was statistically analyzed using 3 measurements per implant. Statistical analyses were performed with SPSS Statistics 23.0 (IBM Corp.).

Results: All implants that passed the stability tests using DCA devices were restored with definitive prostheses and showed no signs of early failure. The DCA-A value demonstrated a very strong correlation with the DCA-P value (DCAV-P), whereas the DCA-T value exhibited only a moderate correlation with DCAV-P. DCA-P also showed the highest reliability, followed by DCA-A and then DCA-T. The reliability of DCA-A and DCA-T was not significantly affected by any of the assessed factors; in contrast, DCA-P's reliability was significantly influenced by arch location and specific quadrant position.

Conclusions: With DCA-P as the reference, DCA-A demonstrated superior accuracy compared to DCA-T. Although DCA-P exhibited the highest reliability, its performance was significantly affected by the positional factors of the target implant.

新型阻尼容量分析装置在临床实践中评估种植体稳定性的比较分析。
目的:假体稳定性测试是假体装载前验证骨整合的关键。已经开发了几种评估骨整合的方法。其中,阻尼能力分析(DCA)设备提供了一种用户友好和非侵入性的方法。在这项研究中,我们评估了新出现的DCA装置在评估种植体稳定性方面的准确性和可靠性。方法:本研究包括37例患者的58个种植体,为期1个月。使用DCA-P (Periotest M, Medizintechnik Gulden)、DCA-A (Anycheck, Neobiotech)和DCA-T (the Trust, Dentium)设备,在愈合基台放置的情况下,对每个种植体进行三次测量。评估诸如愈合基台高度、放置时间、植骨、固定装置直径和固定装置长度等因素。以DCA-P作为参考评估准确性,并通过每个种植体3次测量来统计分析再现性。采用SPSS Statistics 23.0 (IBM Corp.)进行统计学分析。结果:所有使用DCA装置通过稳定性测试的种植体都用确定的假体修复,没有早期失效的迹象。DCA-A值与DCA-P值(DCAV-P)的相关性非常强,而DCA-T值与DCAV-P的相关性仅为中等。DCA-P的信度也最高,其次是DCA-A,然后是DCA-T。DCA-A和DCA-T的可靠性不受任何评估因素的显著影响;相比之下,DCA-P的可靠性受到弓位置和特定象限位置的显著影响。结论:以DCA-P为参照,与DCA-T相比,DCA-A具有更高的准确性。虽然DCA-P具有最高的可靠性,但其性能受到目标种植体位置因素的显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Periodontal and Implant Science
Journal of Periodontal and Implant Science DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
5.30%
发文量
38
期刊介绍: Journal of Periodontal & Implant Science (JPIS) is a peer-reviewed and open-access journal providing up-to-date information relevant to professionalism of periodontology and dental implantology. JPIS is dedicated to global and extensive publication which includes evidence-based original articles, and fundamental reviews in order to cover a variety of interests in the field of periodontal as well as implant science.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信