Su-Bin Hong, Bo-Ah Lee, Woo-Ri Lee, Jung-Seok Lee, Young-Taek Kim
{"title":"Comparative analysis of novel damping capacity analysis devices for assessing implant stability in clinical practice.","authors":"Su-Bin Hong, Bo-Ah Lee, Woo-Ri Lee, Jung-Seok Lee, Young-Taek Kim","doi":"10.5051/jpis.2404680234","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Implant stability testing is crucial for verifying osseointegration before prosthetic loading. Several methods have been developed to assess osseointegration. Among these, damping capacity analysis (DCA) devices offer a user-friendly and non-invasive approach. In this study, we evaluated the accuracy and reliability of newly available DCA devices in assessing dental implant stability.</p><p><strong>Methods: </strong>This study included 58 implants from 37 patients over a 1-month period. Three measurements per implant were obtained with healing abutments in place, following the manufacturers' guidelines, using the DCA-P (Periotest M, Medizintechnik Gulden), DCA-A (Anycheck, Neobiotech), and DCA-T (The Trust, Dentium) devices. Factors such as healing abutment height, time since placement, bone grafting, fixture diameter, and fixture length were evaluated. Accuracy was assessed using DCA-P as the reference, and reproducibility was statistically analyzed using 3 measurements per implant. Statistical analyses were performed with SPSS Statistics 23.0 (IBM Corp.).</p><p><strong>Results: </strong>All implants that passed the stability tests using DCA devices were restored with definitive prostheses and showed no signs of early failure. The DCA-A value demonstrated a very strong correlation with the DCA-P value (DCAV-P), whereas the DCA-T value exhibited only a moderate correlation with DCAV-P. DCA-P also showed the highest reliability, followed by DCA-A and then DCA-T. The reliability of DCA-A and DCA-T was not significantly affected by any of the assessed factors; in contrast, DCA-P's reliability was significantly influenced by arch location and specific quadrant position.</p><p><strong>Conclusions: </strong>With DCA-P as the reference, DCA-A demonstrated superior accuracy compared to DCA-T. Although DCA-P exhibited the highest reliability, its performance was significantly affected by the positional factors of the target implant.</p>","PeriodicalId":48795,"journal":{"name":"Journal of Periodontal and Implant Science","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-04-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Periodontal and Implant Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5051/jpis.2404680234","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Implant stability testing is crucial for verifying osseointegration before prosthetic loading. Several methods have been developed to assess osseointegration. Among these, damping capacity analysis (DCA) devices offer a user-friendly and non-invasive approach. In this study, we evaluated the accuracy and reliability of newly available DCA devices in assessing dental implant stability.
Methods: This study included 58 implants from 37 patients over a 1-month period. Three measurements per implant were obtained with healing abutments in place, following the manufacturers' guidelines, using the DCA-P (Periotest M, Medizintechnik Gulden), DCA-A (Anycheck, Neobiotech), and DCA-T (The Trust, Dentium) devices. Factors such as healing abutment height, time since placement, bone grafting, fixture diameter, and fixture length were evaluated. Accuracy was assessed using DCA-P as the reference, and reproducibility was statistically analyzed using 3 measurements per implant. Statistical analyses were performed with SPSS Statistics 23.0 (IBM Corp.).
Results: All implants that passed the stability tests using DCA devices were restored with definitive prostheses and showed no signs of early failure. The DCA-A value demonstrated a very strong correlation with the DCA-P value (DCAV-P), whereas the DCA-T value exhibited only a moderate correlation with DCAV-P. DCA-P also showed the highest reliability, followed by DCA-A and then DCA-T. The reliability of DCA-A and DCA-T was not significantly affected by any of the assessed factors; in contrast, DCA-P's reliability was significantly influenced by arch location and specific quadrant position.
Conclusions: With DCA-P as the reference, DCA-A demonstrated superior accuracy compared to DCA-T. Although DCA-P exhibited the highest reliability, its performance was significantly affected by the positional factors of the target implant.
期刊介绍:
Journal of Periodontal & Implant Science (JPIS) is a peer-reviewed and open-access journal providing up-to-date information relevant to professionalism of periodontology and dental implantology. JPIS is dedicated to global and extensive publication which includes evidence-based original articles, and fundamental reviews in order to cover a variety of interests in the field of periodontal as well as implant science.