Comparative analysis of indicators of primary stability of implants of different implantological systems at immediate implantation.

Stomatologija Pub Date : 2024-01-01
Dmytro Kaplun, David Avetikov, Serhii Balyuk, Olena Ivanytska, Кateryna Lokes, Ihor Ivanytskyi
{"title":"Comparative analysis of indicators of primary stability of implants of different implantological systems at immediate implantation.","authors":"Dmytro Kaplun, David Avetikov, Serhii Balyuk, Olena Ivanytska, Кateryna Lokes, Ihor Ivanytskyi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>The aim of the study: </strong>Compare the primary stability indicators of implants from various implant systems.</p><p><strong>Materials and methods: </strong>The study enrolled 27 patients; all participants underwent a surgical procedure involving tooth extraction accompanied by simultaneous one-stage dental implantation using Vitaplant VPKS, MegaGen AnyRidge, and Alpha Dent Superior Active implants. To assess primary stability during surgery (a torque test) was conducted. Additionally, the Implant Stability Quotient (ISQ) value was measured utilizing a Penguin RFA apparatus.</p><p><strong>Results and discussion: </strong>Comparing multiple implants reveals a clear pattern and consistency within the torque range of various implant systems. This observation directly indicates the efficacy of their design and surface structure. The obtained data revealed distinct trends in ISQ progression over the 90-day period in patients with one-stage implantation of Alpha Dent Superior Active implants. The dynamics ISQ values from implantation of MegaGen AnyRidge demonstrated slightly regressive trend up to 21 days, followed by a rise in values from day 21. The overall pattern Vitaplant VPKS group resembles that of the previous implant groups, yet with slightly more scattered data.</p><p><strong>Conclusions: </strong>The average indicators of primary implant stability (torque) across all implant systems fall within the range of 10 to 35 N/cm<sup>2</sup>. No signifi cant statistical differences were observed among them. Nonetheless, it should be noted that Alpha Dent Superior Active implants exhibited a slightly higher torque value. The dynamics ISQ of MegaGen and Vitaplant implants demonstrate strikingly similar behavior, while the Alpha Dent implant displays a markedly accelerated healing process.</p>","PeriodicalId":94215,"journal":{"name":"Stomatologija","volume":"26 3","pages":"77-82"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Stomatologija","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of the study: Compare the primary stability indicators of implants from various implant systems.

Materials and methods: The study enrolled 27 patients; all participants underwent a surgical procedure involving tooth extraction accompanied by simultaneous one-stage dental implantation using Vitaplant VPKS, MegaGen AnyRidge, and Alpha Dent Superior Active implants. To assess primary stability during surgery (a torque test) was conducted. Additionally, the Implant Stability Quotient (ISQ) value was measured utilizing a Penguin RFA apparatus.

Results and discussion: Comparing multiple implants reveals a clear pattern and consistency within the torque range of various implant systems. This observation directly indicates the efficacy of their design and surface structure. The obtained data revealed distinct trends in ISQ progression over the 90-day period in patients with one-stage implantation of Alpha Dent Superior Active implants. The dynamics ISQ values from implantation of MegaGen AnyRidge demonstrated slightly regressive trend up to 21 days, followed by a rise in values from day 21. The overall pattern Vitaplant VPKS group resembles that of the previous implant groups, yet with slightly more scattered data.

Conclusions: The average indicators of primary implant stability (torque) across all implant systems fall within the range of 10 to 35 N/cm2. No signifi cant statistical differences were observed among them. Nonetheless, it should be noted that Alpha Dent Superior Active implants exhibited a slightly higher torque value. The dynamics ISQ of MegaGen and Vitaplant implants demonstrate strikingly similar behavior, while the Alpha Dent implant displays a markedly accelerated healing process.

即刻种植时不同种植系统种植体初级稳定性指标的比较分析。
本研究的目的:比较不同种植体系统种植体的主要稳定性指标。材料和方法:纳入27例患者;所有的参与者都接受了外科手术,包括拔牙,同时使用Vitaplant VPKS、MegaGen AnyRidge和Alpha Dent Superior Active种植体进行一期种植。为了评估手术期间的初步稳定性(扭矩试验)。此外,使用企鹅RFA仪测量种植体稳定商(ISQ)值。结果和讨论:比较多个种植体揭示了不同种植体系统的扭矩范围内的清晰模式和一致性。这一观察结果直接表明了它们的设计和表面结构的有效性。获得的数据显示,在一期植入Alpha凹痕高级主动植入的患者中,在90天内ISQ进展有明显的趋势。植入MegaGen AnyRidge后的动态ISQ值在21天内呈轻微的回归趋势,随后从21天开始升高。Vitaplant VPKS组的整体模式与之前的种植体组相似,但数据稍微分散。结论:所有种植体系统的初级种植体稳定性(扭矩)的平均指标在10至35 N/cm2之间。各组间差异无统计学意义。尽管如此,应该注意的是,Alpha凹痕高级主动植入物表现出略高的扭矩值。MegaGen和Vitaplant种植体的动态ISQ表现出惊人的相似行为,而Alpha Dent种植体显示出明显加速的愈合过程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信