An LC/MS/MS method for quantifying 25-hydroxyvitamin D3 in finger-prick plasma sample prepared by DEMECAL® micro plasma separation device: toward mail-in assessment of vitamin D status.
{"title":"An LC/MS/MS method for quantifying 25-hydroxyvitamin D<sub>3</sub> in finger-prick plasma sample prepared by DEMECAL<sup>®</sup> micro plasma separation device: toward mail-in assessment of vitamin D status.","authors":"Kodai Maeda, Kyoka Sakamoto, Eiko Ito, Shinya Sugimoto, Shingo Tajima, Takahisa Sasahara, Shunji Kawamura, Kazuo Yaegashi, Tatsuya Higashi","doi":"10.1007/s00216-025-05939-4","DOIUrl":null,"url":null,"abstract":"<p><p>A mail-in assessment of vitamin D status will make it possible for the subjects to early detect any vitamin D insufficiency/deficiency at their homes, thus leading to a better management of their health. In this study, a liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated for quantifying 25-hydroxyvitamin D<sub>3</sub> [25(OH)D<sub>3</sub>], which is the established marker of the vitamin D status, in the finger-prick blood plasma sample prepared by the DEMECAL<sup>®</sup> device. By using the DEMECAL<sup>®</sup> device, the subjects can collect their finger-prick blood at their homes and immediately separate the plasma from the blood by themselves. The DEMECAL<sup>®</sup>-based procedure had advantages over the venipuncture- and dried blood spot-based procedures because it is less invasive and a medical professional-free blood collection, and no need to be concerned with the heterogeneity of the analyte distribution in the sample. The developed LC/ESI-MS/MS method enabled the precise and accurate quantification of 25(OH)D<sub>3</sub> and provided the lower limit of quantification of 0.10 ng/mL in the diluted plasma sample due to the derivatization with 4-(4-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione. 25(OH)D<sub>3</sub> was stable in the plasma sample prepared by the DEMECAL<sup>®</sup> device at room temperature (23-27 °C) for 7 days (simulated condition in the mail) and at 4 °C for 30 days (simulated condition during storage at a laboratory). The measured 25(OH)D<sub>3</sub> concentrations by the DEMECAL<sup>®</sup>-based procedure well agreed with those by the conventional venipuncture-based procedure. These results demonstrated that the derivatization-LC/ESI-MS/MS combined with the DEMECAL<sup>®</sup>-based sample preparation is a promising procedure for the mail-in assessment of the vitamin D status.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2025-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-025-05939-4","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
A mail-in assessment of vitamin D status will make it possible for the subjects to early detect any vitamin D insufficiency/deficiency at their homes, thus leading to a better management of their health. In this study, a liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated for quantifying 25-hydroxyvitamin D3 [25(OH)D3], which is the established marker of the vitamin D status, in the finger-prick blood plasma sample prepared by the DEMECAL® device. By using the DEMECAL® device, the subjects can collect their finger-prick blood at their homes and immediately separate the plasma from the blood by themselves. The DEMECAL®-based procedure had advantages over the venipuncture- and dried blood spot-based procedures because it is less invasive and a medical professional-free blood collection, and no need to be concerned with the heterogeneity of the analyte distribution in the sample. The developed LC/ESI-MS/MS method enabled the precise and accurate quantification of 25(OH)D3 and provided the lower limit of quantification of 0.10 ng/mL in the diluted plasma sample due to the derivatization with 4-(4-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione. 25(OH)D3 was stable in the plasma sample prepared by the DEMECAL® device at room temperature (23-27 °C) for 7 days (simulated condition in the mail) and at 4 °C for 30 days (simulated condition during storage at a laboratory). The measured 25(OH)D3 concentrations by the DEMECAL®-based procedure well agreed with those by the conventional venipuncture-based procedure. These results demonstrated that the derivatization-LC/ESI-MS/MS combined with the DEMECAL®-based sample preparation is a promising procedure for the mail-in assessment of the vitamin D status.
期刊介绍:
Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.