Suboptimal Inter-Rater Reliability Limits Predictive Value of Fetal Echocardiography for Neonatal Balloon Atrial Septostomy in Fetuses with Dextro-Transposition of the Great Arteries.
Hamsika Chandrasekar, Shiraz A Maskatia, Meaghan J Beattie, Michelle A Kaplinski, Rajesh Punn, Charitha D Reddy, Alexandria Jensen, Theresa A Tacy
{"title":"Suboptimal Inter-Rater Reliability Limits Predictive Value of Fetal Echocardiography for Neonatal Balloon Atrial Septostomy in Fetuses with Dextro-Transposition of the Great Arteries.","authors":"Hamsika Chandrasekar, Shiraz A Maskatia, Meaghan J Beattie, Michelle A Kaplinski, Rajesh Punn, Charitha D Reddy, Alexandria Jensen, Theresa A Tacy","doi":"10.1016/j.echo.2025.05.017","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Dextro-transposition of the great arteries (d-TGA) neonates require adequate mixing at the atrial level. Without this, they experience severe cyanosis, necessitating balloon atrial septostomy (BAS). Multiple studies have identified various fetal echocardiogram (FE) findings as risk factors for postnatal BAS. The predictive value of these findings remains poor in clinical use.</p><p><strong>Hypothesis: </strong>We aimed to determine the relationship between inter-rater reliability (IRR) of FE BAS predictors and postnatal BAS, as well as postnatal markers of hypoxia/hypoxemia. We hypothesized that poor IRR may contribute to limited FE predictive value.</p><p><strong>Methods: </strong>We identified d-TGA pregnancies followed at our institution between 2012 and 2022, excluding fetuses with large ventricular septal defects and pregnancies terminated or lost to follow up. Two groups of three independent readers blinded to BAS outcome assessed 7 FE predictors: peak pulmonary vein Doppler velocity > 41 cm/sec, reverse flow in patent ductus arteriosus (PDA), restrictive PDA, restrictive patent foramen ovale (PFO), bidirectional PFO flow, flat septum primum, and hypermobile septum primum. IRR was determined with the S metric. Clinical information before BAS was collected to evaluate postnatal physiology. A multivariable logistic regression was used to determine significant associations between FE findings and postnatal BAS. Multivariable linear regressions were also used to determine significant associations between FE findings and indicators of hypoxia/hypoxemia.</p><p><strong>Results: </strong>Fifty-two fetuses were included, of whom 25 (48%) underwent BAS. FEs were performed at a mean gestational age of 34.02 weeks (SD 2.14 weeks). IRR was lowest for PFO flow direction and highest for restrictive PDA, likely due to its rarity. The remainder of FE predictors had either moderate or substantial IRR. Five FE characteristics could be included in the regression analysis, and none were significantly associated with odds of BAS, postnatal pH, or postnatal oxygen saturation. Reverse PDA flow was statistically significantly associated with lower postnatal pre-BAS paO2.</p><p><strong>Conclusions: </strong>Our results demonstrate substantial but not excellent IRR for current FE BAS predictors. There was no significant association between these predictors and postnatal BAS or postnatal hypoxia/hypoxemia in d-TGA patients, except for reverse PDA flow and lower postnatal paO2. Additional work is needed to identify more reliable FE predictors of postnatal d-TGA physiology.</p>","PeriodicalId":50011,"journal":{"name":"Journal of the American Society of Echocardiography","volume":" ","pages":""},"PeriodicalIF":5.4000,"publicationDate":"2025-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Society of Echocardiography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.echo.2025.05.017","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Dextro-transposition of the great arteries (d-TGA) neonates require adequate mixing at the atrial level. Without this, they experience severe cyanosis, necessitating balloon atrial septostomy (BAS). Multiple studies have identified various fetal echocardiogram (FE) findings as risk factors for postnatal BAS. The predictive value of these findings remains poor in clinical use.
Hypothesis: We aimed to determine the relationship between inter-rater reliability (IRR) of FE BAS predictors and postnatal BAS, as well as postnatal markers of hypoxia/hypoxemia. We hypothesized that poor IRR may contribute to limited FE predictive value.
Methods: We identified d-TGA pregnancies followed at our institution between 2012 and 2022, excluding fetuses with large ventricular septal defects and pregnancies terminated or lost to follow up. Two groups of three independent readers blinded to BAS outcome assessed 7 FE predictors: peak pulmonary vein Doppler velocity > 41 cm/sec, reverse flow in patent ductus arteriosus (PDA), restrictive PDA, restrictive patent foramen ovale (PFO), bidirectional PFO flow, flat septum primum, and hypermobile septum primum. IRR was determined with the S metric. Clinical information before BAS was collected to evaluate postnatal physiology. A multivariable logistic regression was used to determine significant associations between FE findings and postnatal BAS. Multivariable linear regressions were also used to determine significant associations between FE findings and indicators of hypoxia/hypoxemia.
Results: Fifty-two fetuses were included, of whom 25 (48%) underwent BAS. FEs were performed at a mean gestational age of 34.02 weeks (SD 2.14 weeks). IRR was lowest for PFO flow direction and highest for restrictive PDA, likely due to its rarity. The remainder of FE predictors had either moderate or substantial IRR. Five FE characteristics could be included in the regression analysis, and none were significantly associated with odds of BAS, postnatal pH, or postnatal oxygen saturation. Reverse PDA flow was statistically significantly associated with lower postnatal pre-BAS paO2.
Conclusions: Our results demonstrate substantial but not excellent IRR for current FE BAS predictors. There was no significant association between these predictors and postnatal BAS or postnatal hypoxia/hypoxemia in d-TGA patients, except for reverse PDA flow and lower postnatal paO2. Additional work is needed to identify more reliable FE predictors of postnatal d-TGA physiology.
期刊介绍:
The Journal of the American Society of Echocardiography(JASE) brings physicians and sonographers peer-reviewed original investigations and state-of-the-art review articles that cover conventional clinical applications of cardiovascular ultrasound, as well as newer techniques with emerging clinical applications. These include three-dimensional echocardiography, strain and strain rate methods for evaluating cardiac mechanics and interventional applications.