Comparison Of Transfer Accuracy Among Hexed Implant Mounts, Clips Impression Copings, And Open-Tray Impression Copings at Different Implant Angulations: An In Vitro Study.

IF 3.1 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Merna M Seif, Ahmed A Abdel Hakim, Hassan M Abouelkheir, Rana A Negm
{"title":"Comparison Of Transfer Accuracy Among Hexed Implant Mounts, Clips Impression Copings, And Open-Tray Impression Copings at Different Implant Angulations: An In Vitro Study.","authors":"Merna M Seif, Ahmed A Abdel Hakim, Hassan M Abouelkheir, Rana A Negm","doi":"10.1186/s12903-025-06304-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Accurate impression registration is essential for transferring the three-dimensional (3D) implant position to the definitive cast, ensuring passivity of the final prosthesis. Various impression techniques have been developed to optimize accuracy, particularly for angulated implants. This study aimed to evaluate and compare the accuracy of open-tray impression copings, clips impression copings, and hexed implant mounts in transferring implant positions for both straight and angulated implants.</p><p><strong>Methods: </strong>Five implants with different angulations (three at 0°, one at 15°, and one at 25°) were placed in an epoxy resin model, reflecting angulations commonly encountered in clinical practice. Thirty impressions were made using three types of impression copings: open-tray, clips (closed-tray), and hexed implant mounts (closed-tray), with ten impressions per group. Impressions were poured, and CBCT scans of the reference model and casts were obtained. The resulting DICOM files were converted to STL format using reverse engineering software to evaluate implant position accuracy based on shoulder deviation, apical deviation, angular deviation, and vertical shift. A significance level of p < 0.05 was set. One-way ANOVA and post hoc tests were performed; Tukey's HSD was applied when variance homogeneity was met, while the Games-Howell test was used when this assumption was violated.</p><p><strong>Results: </strong>The study revealed that among the three coping types, the hexed implant mount demonstrated significantly higher angular deviation (p < 0.001), apical deviation (p = 0.003), and vertical shift (p < 0.001) for 25° angulated implants compared to the open-tray and clips copings. There were no significant differences between the open-tray and clips groups at this angulation. At 15° angulation, the hexed implant mount showed a significantly greater vertical shift (p = 0.011) compared to the open-tray coping, while no significant difference was observed between the clips and open-tray copings. For straight implants (0° angulation), all three coping types-open-tray, clips, and hexed implant mounts-showed no significant differences in any measured parameter.</p><p><strong>Conclusions: </strong>Open-tray and clips impression copings provide reliable implant position transfer for straight and angulated implants up to 25°. The hexed implant mount is accurate up to 15° angulation but shows increased deviations at 25°.</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"25 1","pages":"928"},"PeriodicalIF":3.1000,"publicationDate":"2025-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12142942/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-025-06304-8","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Accurate impression registration is essential for transferring the three-dimensional (3D) implant position to the definitive cast, ensuring passivity of the final prosthesis. Various impression techniques have been developed to optimize accuracy, particularly for angulated implants. This study aimed to evaluate and compare the accuracy of open-tray impression copings, clips impression copings, and hexed implant mounts in transferring implant positions for both straight and angulated implants.

Methods: Five implants with different angulations (three at 0°, one at 15°, and one at 25°) were placed in an epoxy resin model, reflecting angulations commonly encountered in clinical practice. Thirty impressions were made using three types of impression copings: open-tray, clips (closed-tray), and hexed implant mounts (closed-tray), with ten impressions per group. Impressions were poured, and CBCT scans of the reference model and casts were obtained. The resulting DICOM files were converted to STL format using reverse engineering software to evaluate implant position accuracy based on shoulder deviation, apical deviation, angular deviation, and vertical shift. A significance level of p < 0.05 was set. One-way ANOVA and post hoc tests were performed; Tukey's HSD was applied when variance homogeneity was met, while the Games-Howell test was used when this assumption was violated.

Results: The study revealed that among the three coping types, the hexed implant mount demonstrated significantly higher angular deviation (p < 0.001), apical deviation (p = 0.003), and vertical shift (p < 0.001) for 25° angulated implants compared to the open-tray and clips copings. There were no significant differences between the open-tray and clips groups at this angulation. At 15° angulation, the hexed implant mount showed a significantly greater vertical shift (p = 0.011) compared to the open-tray coping, while no significant difference was observed between the clips and open-tray copings. For straight implants (0° angulation), all three coping types-open-tray, clips, and hexed implant mounts-showed no significant differences in any measured parameter.

Conclusions: Open-tray and clips impression copings provide reliable implant position transfer for straight and angulated implants up to 25°. The hexed implant mount is accurate up to 15° angulation but shows increased deviations at 25°.

在不同种植体角度下,六角固定种植体、夹片压模和开盘压模的转移精度比较:一项体外研究。
背景:准确的印模配准对于将三维(3D)种植体位置转移到最终铸件,确保最终假体的被动性至关重要。各种压模技术已经发展到优化精度,特别是有角植入物。本研究旨在评估和比较开盘压印钳、夹子压印钳和六角形种植体支架在转移种植体位置时的准确性,用于直种植体和成角种植体。方法:将5个不同角度的种植体(3个为0°,1个为15°,1个为25°)放置在环氧树脂模型中,以反映临床常见的角度。使用三种类型的印模制作30个印模:开盘、夹片(封闭托盘)和六角种植体支架(封闭托盘),每组10个印模。浇铸模,并获得参考模型和铸件的CBCT扫描。使用逆向工程软件将所得的DICOM文件转换为STL格式,以评估基于肩部偏差、根尖偏差、角度偏差和垂直位移的种植体位置准确性。结果:研究显示,在三种类型的顶部中,内六角种植体安装架显示出明显更高的角度偏差(p)。结论:开托盘和夹钳压模顶部为直种植体和成角种植体提供可靠的种植体位置转移,可达25°。内六角植入物安装精确到15°角度,但在25°时显示增加的偏差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信