Performance Evaluation of the 2020 European Society of Cardiology 0-hour/1-hour Algorithm Using High-sensitivity Cardiac Troponin I for Non-ST-segment Elevation Acute Coronary Syndrome and Mortality Assessment Based on 1-year Real-world Data
Changhee Ha, Yeon Jae Lee, Jong Do Seo, Hanah Kim, Hee-Won Moon, Mina Hur, Young Hwan Lee, Sang O Park, Kyeong Ryong Lee, Hyun-Joong Kim, Yeo-Min Yun
{"title":"Performance Evaluation of the 2020 European Society of Cardiology 0-hour/1-hour Algorithm Using High-sensitivity Cardiac Troponin I for Non-ST-segment Elevation Acute Coronary Syndrome and Mortality Assessment Based on 1-year Real-world Data","authors":"Changhee Ha, Yeon Jae Lee, Jong Do Seo, Hanah Kim, Hee-Won Moon, Mina Hur, Young Hwan Lee, Sang O Park, Kyeong Ryong Lee, Hyun-Joong Kim, Yeo-Min Yun","doi":"10.3343/alm.2025.0017","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The 2020 European Society of Cardiology (ESC) 0-hr/1-hr algorithm using high-sensitivity cardiac troponin I (hs-cTnI) for non-ST-segment elevation acute coronary syndrome (NSTE-ACS) aims at early diagnosis and shorter emergency department (ED) stays. While this algorithm has been well-established in controlled studies, real-world implementation remains challenging. We evaluated the algorithm's clinical performance and risk stratification capability in patients with chest pain or discomfort.</p><p><strong>Methods: </strong>We measured hs-cTnI in 4,678 patients suspected of NSTE-ACS between August 2022 and July 2023, using an Atellica IM Analyzer (Siemens Healthineers, Erlangen, Germany). We categorized patients into rule-in, observe, or rule-out groups according to the algorithm and assessed its diagnostic performance for NSTE-ACS. The final diagnosis of NSTE-ACS was adjudicated by two independent physicians. Additionally, we evaluated 30-day all-cause mortality, hazard risk, and ED length of stay across the three groups.</p><p><strong>Results: </strong>The algorithm categorized 3,408 (72.9%), 573 (12.2%), and 697 (14.9%) patients into the rule-out, observe, and rule-in groups, respectively. Among 90 patients diagnosed as having NSTE-ACS, none were falsely categorized into the rule-out group. Survival analysis revealed significant differences (<i>P</i> <0.001), with Cox hazard ratios of 2.38 (95% confidence interval: 1.20-4.71) and 6.39 (3.45-11.86) in the observe and rule-in groups, respectively. ED stays shortened in the order of rule-out, observe, and rule-in groups (<i>P</i> <0.001).</p><p><strong>Conclusions: </strong>The 2020 ESC 0-hr/1-hr algorithm demonstrates excellent diagnostic accuracy without false rule-outs and effective risk stratification, and contributes to efficient ED throughput, supporting its clinical utility in real-world emergency settings.</p>","PeriodicalId":8421,"journal":{"name":"Annals of Laboratory Medicine","volume":" ","pages":""},"PeriodicalIF":3.9000,"publicationDate":"2025-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Laboratory Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3343/alm.2025.0017","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The 2020 European Society of Cardiology (ESC) 0-hr/1-hr algorithm using high-sensitivity cardiac troponin I (hs-cTnI) for non-ST-segment elevation acute coronary syndrome (NSTE-ACS) aims at early diagnosis and shorter emergency department (ED) stays. While this algorithm has been well-established in controlled studies, real-world implementation remains challenging. We evaluated the algorithm's clinical performance and risk stratification capability in patients with chest pain or discomfort.
Methods: We measured hs-cTnI in 4,678 patients suspected of NSTE-ACS between August 2022 and July 2023, using an Atellica IM Analyzer (Siemens Healthineers, Erlangen, Germany). We categorized patients into rule-in, observe, or rule-out groups according to the algorithm and assessed its diagnostic performance for NSTE-ACS. The final diagnosis of NSTE-ACS was adjudicated by two independent physicians. Additionally, we evaluated 30-day all-cause mortality, hazard risk, and ED length of stay across the three groups.
Results: The algorithm categorized 3,408 (72.9%), 573 (12.2%), and 697 (14.9%) patients into the rule-out, observe, and rule-in groups, respectively. Among 90 patients diagnosed as having NSTE-ACS, none were falsely categorized into the rule-out group. Survival analysis revealed significant differences (P <0.001), with Cox hazard ratios of 2.38 (95% confidence interval: 1.20-4.71) and 6.39 (3.45-11.86) in the observe and rule-in groups, respectively. ED stays shortened in the order of rule-out, observe, and rule-in groups (P <0.001).
Conclusions: The 2020 ESC 0-hr/1-hr algorithm demonstrates excellent diagnostic accuracy without false rule-outs and effective risk stratification, and contributes to efficient ED throughput, supporting its clinical utility in real-world emergency settings.