Multi-channel Hcy/FA aptasensors and cTnT immunosensors used for early screening of H-type hypertension and myocardial infarction

IF 4.2 3区 工程技术 Q2 ELECTROCHEMISTRY
Xinjie Song , Jie Fu , Jiawang Wang , Fangying Xiong , Jing Zhang , Shuang Li
{"title":"Multi-channel Hcy/FA aptasensors and cTnT immunosensors used for early screening of H-type hypertension and myocardial infarction","authors":"Xinjie Song ,&nbsp;Jie Fu ,&nbsp;Jiawang Wang ,&nbsp;Fangying Xiong ,&nbsp;Jing Zhang ,&nbsp;Shuang Li","doi":"10.1016/j.elecom.2025.107966","DOIUrl":null,"url":null,"abstract":"<div><div>Elevated levels of homocysteine (Hcy) and decreased levels of folic acid (FA) are frequently observed in individuals with H-type hypertension (HTH). However, HTH increases Repeatability, reproducibility and stability of Hcy aptasensorrisk of acute myocardial infarction (AMI). Elevated cardiac troponin T (cTnT) levels are particularly significant in patients with AMI. Nevertheless, the effective detection of Hcy, FA, and cTnT remains challenging due to the lack of a reliable, cost-effective, and rapid method that can accurately predict, promptly detect, and effectively guide the treatment of these conditions. To address this issue, aptasensors for Hcy and FA as well as immunosensors for cTnT were developed based on amultiple electrochemical system. The concentration of Hcy and FA exhibited a good linear relationship with the relative redox peak current within the ranges of 1–100 μM and 10–50 nM, respectively, due to conformational changes in the aptamer. Similarly, the concentration of cTnT demonstrated a good linear relationship with the relative redox peak current of the electrode within the range of 1–60 pg/mL, attributed to changes in electron transfer following antigen-antibody binding. The experimental results confirmed that the aptasensors and immunosensors exhibited excellent repeatability, reproducibility, stability, and specificity. In real serum sample, this biosensor showed an acceptable recovery rate. These findings suggest that the proposed sensors hold significant potential for the early detection of HTH and AMI.</div></div>","PeriodicalId":304,"journal":{"name":"Electrochemistry Communications","volume":"177 ","pages":"Article 107966"},"PeriodicalIF":4.2000,"publicationDate":"2025-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrochemistry Communications","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1388248125001055","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 0

Abstract

Elevated levels of homocysteine (Hcy) and decreased levels of folic acid (FA) are frequently observed in individuals with H-type hypertension (HTH). However, HTH increases Repeatability, reproducibility and stability of Hcy aptasensorrisk of acute myocardial infarction (AMI). Elevated cardiac troponin T (cTnT) levels are particularly significant in patients with AMI. Nevertheless, the effective detection of Hcy, FA, and cTnT remains challenging due to the lack of a reliable, cost-effective, and rapid method that can accurately predict, promptly detect, and effectively guide the treatment of these conditions. To address this issue, aptasensors for Hcy and FA as well as immunosensors for cTnT were developed based on amultiple electrochemical system. The concentration of Hcy and FA exhibited a good linear relationship with the relative redox peak current within the ranges of 1–100 μM and 10–50 nM, respectively, due to conformational changes in the aptamer. Similarly, the concentration of cTnT demonstrated a good linear relationship with the relative redox peak current of the electrode within the range of 1–60 pg/mL, attributed to changes in electron transfer following antigen-antibody binding. The experimental results confirmed that the aptasensors and immunosensors exhibited excellent repeatability, reproducibility, stability, and specificity. In real serum sample, this biosensor showed an acceptable recovery rate. These findings suggest that the proposed sensors hold significant potential for the early detection of HTH and AMI.

Abstract Image

多通道Hcy/FA配体传感器和cTnT免疫传感器在h型高血压和心肌梗死早期筛查中的应用
同型半胱氨酸(Hcy)水平升高和叶酸(FA)水平降低在h型高血压(HTH)患者中经常观察到。然而,HTH增加了Hcy对急性心肌梗死(AMI)风险的重复性、再现性和稳定性。心肌肌钙蛋白T (cTnT)水平升高在AMI患者中尤为显著。然而,由于缺乏一种可靠、经济、快速的方法来准确预测、及时检测和有效指导这些疾病的治疗,Hcy、FA和cTnT的有效检测仍然具有挑战性。为了解决这一问题,开发了基于多电化学系统的Hcy和FA适配传感器以及cTnT免疫传感器。在1 ~ 100 μM和10 ~ 50 nM范围内,Hcy和FA浓度与相对氧化还原峰电流呈良好的线性关系,这是由于适体的构象变化所致。同样,cTnT的浓度与电极的相对氧化还原峰电流在1-60 pg/mL范围内表现出良好的线性关系,这归因于抗原-抗体结合后电子转移的变化。实验结果证实,适体传感器和免疫传感器具有良好的重复性、再现性、稳定性和特异性。在实际血清样品中,该生物传感器显示出可接受的回收率。这些发现表明,所提出的传感器在HTH和AMI的早期检测中具有重要的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Electrochemistry Communications
Electrochemistry Communications 工程技术-电化学
CiteScore
8.50
自引率
3.70%
发文量
160
审稿时长
1.2 months
期刊介绍: Electrochemistry Communications is an open access journal providing fast dissemination of short communications, full communications and mini reviews covering the whole field of electrochemistry which merit urgent publication. Short communications are limited to a maximum of 20,000 characters (including spaces) while full communications and mini reviews are limited to 25,000 characters (including spaces). Supplementary information is permitted for full communications and mini reviews but not for short communications. We aim to be the fastest journal in electrochemistry for these types of papers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信