To Investigate the Laboratory Sample Criteria of Ammonia Measurement in Saudi Arabia.

IF 0.7 Q3 MEDICINE, GENERAL & INTERNAL
Annals of African Medicine Pub Date : 2025-07-01 Epub Date: 2025-05-30 DOI:10.4103/aam.aam_80_24
Mohammed Abdullah Jeraiby
{"title":"To Investigate the Laboratory Sample Criteria of Ammonia Measurement in Saudi Arabia.","authors":"Mohammed Abdullah Jeraiby","doi":"10.4103/aam.aam_80_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of this study was to investigate the laboratory sample acceptance criteria, ammonia analysis, and the reporting of ammonia results and raise awareness of the new guidelines.</p><p><strong>Methods: </strong>It is a descriptive cross-sectional study. The study was conducted in the clinical laboratories of the hospital, KSA. Furthermore, the study used electronic questionnaires. A questionnaire was distributed to clinical biochemistry laboratories in Saudi Arabia. The results were collected and compared to updated best practice guidelines on hyperammonemia issued by the Metabolic Biochemistry Network (MetBio.net).</p><p><strong>Results: </strong>This study examined laboratory practices in ammonia analysis. EDTA tubes are widely used (78.0%) for blood/plasma ammonia measurement. Most laboratories prioritize sample delivery on ice (100%) and fast-track samples for ammonia analysis (95.1%). Awareness of ammonia analysis criteria includes automated methods for hemolysis assessment (61.0%) and rejection of grossly hemolyzed samples (92.7%). The enzymatic method is predominant (97.6%). Concerns about icterus and lipemia impact (80.5% and 85.4%, respectively) are noted. Reporting practices vary, with 65.9% setting specific thresholds for critical limits.</p><p><strong>Conclusion: </strong>This study offers insights into current ammonia analysis practices, identifying areas for improvement. Aligning with literature, it emphasizes the need for ongoing education and guideline updates for consistent and accurate severe hyperammonemia diagnosis and management.</p>","PeriodicalId":7938,"journal":{"name":"Annals of African Medicine","volume":" ","pages":"573-578"},"PeriodicalIF":0.7000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of African Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/aam.aam_80_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/5/30 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The aim of this study was to investigate the laboratory sample acceptance criteria, ammonia analysis, and the reporting of ammonia results and raise awareness of the new guidelines.

Methods: It is a descriptive cross-sectional study. The study was conducted in the clinical laboratories of the hospital, KSA. Furthermore, the study used electronic questionnaires. A questionnaire was distributed to clinical biochemistry laboratories in Saudi Arabia. The results were collected and compared to updated best practice guidelines on hyperammonemia issued by the Metabolic Biochemistry Network (MetBio.net).

Results: This study examined laboratory practices in ammonia analysis. EDTA tubes are widely used (78.0%) for blood/plasma ammonia measurement. Most laboratories prioritize sample delivery on ice (100%) and fast-track samples for ammonia analysis (95.1%). Awareness of ammonia analysis criteria includes automated methods for hemolysis assessment (61.0%) and rejection of grossly hemolyzed samples (92.7%). The enzymatic method is predominant (97.6%). Concerns about icterus and lipemia impact (80.5% and 85.4%, respectively) are noted. Reporting practices vary, with 65.9% setting specific thresholds for critical limits.

Conclusion: This study offers insights into current ammonia analysis practices, identifying areas for improvement. Aligning with literature, it emphasizes the need for ongoing education and guideline updates for consistent and accurate severe hyperammonemia diagnosis and management.

目的探讨沙特阿拉伯测定氨的实验室样品标准。
目的:本研究旨在探讨实验室样品验收标准、氨分析和氨结果报告,并提高对新指南的认识。方法:采用描述性横断面研究。这项研究是在KSA医院的临床实验室进行的。此外,该研究使用了电子问卷。向沙特阿拉伯的临床生物化学实验室分发了一份调查表。收集结果并与代谢生物化学网络(MetBio.net)发布的最新高氨血症最佳实践指南进行比较。结果:本研究检查了氨分析的实验室实践。EDTA管广泛用于血/血浆氨测量(78.0%)。大多数实验室优先考虑冰上样品递送(100%)和快速通道样品进行氨分析(95.1%)。了解氨分析标准包括溶血评估的自动化方法(61.0%)和严重溶血样品的拒绝(92.7%)。酶法为主要方法(97.6%)。注意到对黄疸和血脂影响的担忧(分别为80.5%和85.4%)。报告实践各不相同,65.9%的人为关键限制设置了特定的阈值。结论:这项研究为当前的氨分析实践提供了见解,确定了需要改进的领域。与文献一致,它强调需要持续的教育和指南更新,以一致和准确的严重高氨血症诊断和管理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of African Medicine
Annals of African Medicine MEDICINE, GENERAL & INTERNAL-
CiteScore
0.90
自引率
0.00%
发文量
31
期刊介绍: The Annals of African Medicine is published by the Usmanu Danfodiyo University Teaching Hospital, Sokoto, Nigeria and the Annals of African Medicine Society. The Journal is intended to serve as a medium for the publication of research findings in the broad field of Medicine in Africa and other developing countries, and elsewhere which have relevance to Africa. It will serve as a source of information on the state of the art of Medicine in Africa, for continuing education for doctors in Africa and other developing countries, and also for the publication of meetings and conferences. The journal will publish articles I any field of Medicine and other fields which have relevance or implications for Medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信