{"title":"[Accuracy evaluation of airborne pollen concentrations monitored by a new volumetric suction pollen monitor].","authors":"Y H Ouyang, J Yang, J X Zhang, Y Yan, L Zhang","doi":"10.3760/cma.j.cn115330-20240501-00257","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To evaluate the accuracy of airborne pollen concentrations monitored by a novel volumetric suction pollen monitor. <b>Methods:</b> During the peak period of autumn pollen concentration in Beijing from September 1st to 27th, the pollen concentration was collected using gravitational and volumetric pollen monitor, and the correlation of pollen concentration between two kind of pollen monitor was analyzed. The effects of daily mean temperature, relative humidity and wind speed on the real-time pollen concentration of the volumetric suction pollen monitor were also analyzed. SPSS 25.0 software was used for statistical analysis. <b>Results:</b> There was significant correlation between the pollen concentration obtained by the two collectors (<i>r<sub>s</sub></i> value was 0.85 and 0.86, respectively, both <i>P</i><0.001). Using a volumetric suction monitor, the pollen concentration in the horizontal 3 lines of the pollen sample (12.5%) under a 200×microscope was significantly correlated with the pollen concentration in the whole sample (<i>r<sub>s</sub></i>=0.97, <i>P</i><0.001). The real-time pollen concentration collected by the volumetric suction monitor within 24 hours was greatly affected by the daily average temperature (all <i>P</i><0.05), and the pollen concentration increased with the daytime temperature, which was not affected by the relative humidity and the average wind speed (all <i>P</i>>0.05). <b>Conclusion:</b> The airborne pollen concentration monitored by new volumetric pollen monitor has high accuracy and can accurately achieve real-time.</p>","PeriodicalId":23987,"journal":{"name":"Chinese journal of otorhinolaryngology head and neck surgery","volume":"60 5","pages":"527-531"},"PeriodicalIF":0.0000,"publicationDate":"2025-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese journal of otorhinolaryngology head and neck surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn115330-20240501-00257","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the accuracy of airborne pollen concentrations monitored by a novel volumetric suction pollen monitor. Methods: During the peak period of autumn pollen concentration in Beijing from September 1st to 27th, the pollen concentration was collected using gravitational and volumetric pollen monitor, and the correlation of pollen concentration between two kind of pollen monitor was analyzed. The effects of daily mean temperature, relative humidity and wind speed on the real-time pollen concentration of the volumetric suction pollen monitor were also analyzed. SPSS 25.0 software was used for statistical analysis. Results: There was significant correlation between the pollen concentration obtained by the two collectors (rs value was 0.85 and 0.86, respectively, both P<0.001). Using a volumetric suction monitor, the pollen concentration in the horizontal 3 lines of the pollen sample (12.5%) under a 200×microscope was significantly correlated with the pollen concentration in the whole sample (rs=0.97, P<0.001). The real-time pollen concentration collected by the volumetric suction monitor within 24 hours was greatly affected by the daily average temperature (all P<0.05), and the pollen concentration increased with the daytime temperature, which was not affected by the relative humidity and the average wind speed (all P>0.05). Conclusion: The airborne pollen concentration monitored by new volumetric pollen monitor has high accuracy and can accurately achieve real-time.

[一种新型体积吸力花粉监测仪监测空气中花粉浓度的准确性评价]。
目的:评价新型容积吸力花粉监测仪监测空气中花粉浓度的准确性。方法:在9月1日至27日北京地区秋季花粉浓度高峰期,采用重力式和体积式花粉监测仪采集花粉浓度,分析两种花粉监测仪花粉浓度的相关性。分析了日平均温度、相对湿度和风速对容积吸力花粉监测仪实时花粉浓度的影响。采用SPSS 25.0软件进行统计分析。结果:两种采集者采集的花粉浓度具有显著相关性(rs值分别为0.85和0.86,pr值均为0.97,PPP值均为0.05)。结论:新型容积式花粉监测仪监测空气中花粉浓度准确度高,能准确实现实时性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
12432
期刊介绍: Chinese journal of otorhinolaryngology head and neck surgery is a high-level medical science and technology journal sponsored and published directly by the Chinese Medical Association, reflecting the significant research progress in the field of otorhinolaryngology head and neck surgery in China, and striving to promote the domestic and international academic exchanges for the purpose of running the journal. Over the years, the journal has been ranked first in the total citation frequency list of national scientific and technical journals published by the Documentation and Intelligence Center of the Chinese Academy of Sciences and the China Science Citation Database, and has always ranked first among the scientific and technical journals in the related fields. Chinese journal of otorhinolaryngology head and neck surgery has been included in the authoritative databases PubMed, Chinese core journals, CSCD.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信