Reliability and Validity of the Streamlined Wolf Motor Function Test for Chronic Stroke.

IF 1.1 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Malaysian Journal of Medical Sciences Pub Date : 2025-02-01 Epub Date: 2025-02-28 DOI:10.21315/mjms-09-2024-736
Su Sandi Hla Tun, Sawitri Wanpen, Nomjit Nualnetr, Uraiwan Chatchawan, Rungthip Puntumetakul, Myitzu Khin
{"title":"Reliability and Validity of the Streamlined Wolf Motor Function Test for Chronic Stroke.","authors":"Su Sandi Hla Tun, Sawitri Wanpen, Nomjit Nualnetr, Uraiwan Chatchawan, Rungthip Puntumetakul, Myitzu Khin","doi":"10.21315/mjms-09-2024-736","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The present study evaluated the reliability and validity of the Streamlined Wolf Motor Function Test for Chronic Stroke (SWMFT-C), a shortened and redesigned version of the Wolf Motor Function Test (WMFT) to determine upper extremity (UE) motor abilities.</p><p><strong>Methods: </strong>Twenty individuals with chronic stroke were included in a cross-sectional study design. The Fugl-Meyer Assessment of the Upper Extremity (FMA-UE) and the Stroke Impact Scale (SIS) were used to assess impaired motor recovery of the UE in these patients. The SWMFT-C's test-retest (two weeks) reliability and inter-rater reliability (three physical therapists) were examined using the intra-class correlation coefficients (ICCs) ICC<sub>2,1</sub> and ICC<sub>3,1</sub>. Validity was analysed by FMA-UE and SIS-hand function at baseline and 2 weeks using Pearson's <i>r</i> values.</p><p><strong>Results: </strong>The SWMFT-C performance time(s) demonstrated excellent test-retest reliability (ICC<sub>3,1</sub> = 0.943, 95% confidence interval [CI] = 0.859-0.978, standard error of measurement [SEM] = 0.15) and outstanding inter-rater reliability (ICC<sub>2,1</sub> = 0.999, 95% CI = 0.998-1.000, SEM = 1.15). The functional ability scale (FAS) also demonstrated excellent test-retest reliability (ICC<sub>3,1</sub> = 0.945, 95% CI = 0.861-0.978, SEM = 0.12) and inter-rater reliability (ICC<sub>2,1</sub> = 0.973, 95% CI = 0.944-0.989, SEM = 0.18). Internal consistency (IC) was calculated using the overall Cronbach's alpha and demonstrated outstanding agreement as shown by values of 0.99 and 0.94 in performance time(s) and FAS, respectively; the values of minimum detectable change (MDC<sub>95</sub>) were 2.26 seconds and 0.34 seconds, respectively. The validity was good to excellent as correlated with FMA-UE and SIS-hand function, ranging from -0.86 to -0.52 in performance time(s) and 0.65 to 0.80 in FAS.</p><p><strong>Conclusion: </strong>The SWMFT-C is a valid, reliable clinical instrument for the population with chronic stroke.</p>","PeriodicalId":47388,"journal":{"name":"Malaysian Journal of Medical Sciences","volume":"32 1","pages":"110-120"},"PeriodicalIF":1.1000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12097163/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Malaysian Journal of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21315/mjms-09-2024-736","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/28 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The present study evaluated the reliability and validity of the Streamlined Wolf Motor Function Test for Chronic Stroke (SWMFT-C), a shortened and redesigned version of the Wolf Motor Function Test (WMFT) to determine upper extremity (UE) motor abilities.

Methods: Twenty individuals with chronic stroke were included in a cross-sectional study design. The Fugl-Meyer Assessment of the Upper Extremity (FMA-UE) and the Stroke Impact Scale (SIS) were used to assess impaired motor recovery of the UE in these patients. The SWMFT-C's test-retest (two weeks) reliability and inter-rater reliability (three physical therapists) were examined using the intra-class correlation coefficients (ICCs) ICC2,1 and ICC3,1. Validity was analysed by FMA-UE and SIS-hand function at baseline and 2 weeks using Pearson's r values.

Results: The SWMFT-C performance time(s) demonstrated excellent test-retest reliability (ICC3,1 = 0.943, 95% confidence interval [CI] = 0.859-0.978, standard error of measurement [SEM] = 0.15) and outstanding inter-rater reliability (ICC2,1 = 0.999, 95% CI = 0.998-1.000, SEM = 1.15). The functional ability scale (FAS) also demonstrated excellent test-retest reliability (ICC3,1 = 0.945, 95% CI = 0.861-0.978, SEM = 0.12) and inter-rater reliability (ICC2,1 = 0.973, 95% CI = 0.944-0.989, SEM = 0.18). Internal consistency (IC) was calculated using the overall Cronbach's alpha and demonstrated outstanding agreement as shown by values of 0.99 and 0.94 in performance time(s) and FAS, respectively; the values of minimum detectable change (MDC95) were 2.26 seconds and 0.34 seconds, respectively. The validity was good to excellent as correlated with FMA-UE and SIS-hand function, ranging from -0.86 to -0.52 in performance time(s) and 0.65 to 0.80 in FAS.

Conclusion: The SWMFT-C is a valid, reliable clinical instrument for the population with chronic stroke.

流线型Wolf运动功能测试对慢性脑卒中的信度和效度。
背景:本研究评估了慢性卒中的流线型Wolf运动功能测试(SWMFT-C)的信度和效度,这是Wolf运动功能测试(WMFT)的简化和重新设计版本,用于确定上肢(UE)的运动能力。方法:20例慢性脑卒中患者采用横断面研究设计。使用Fugl-Meyer上肢评估(FMA-UE)和卒中影响量表(SIS)评估这些患者上肢运动恢复受损。采用类内相关系数(ICCs) ICC2,1和ICC3,1对SWMFT-C的重测(两周)信度和评定者间信度(三名物理治疗师)进行检验。在基线和2周使用Pearson’s r值通过FMA-UE和SIS-hand函数分析有效性。结果:SWMFT-C表现时间(s)具有优异的重测信度(ICC3,1 = 0.943, 95%可信区间[CI] = 0.859 ~ 0.978,计量标准误差[SEM] = 0.15)和优异的评估间信度(ICC2,1 = 0.999, 95% CI = 0.998 ~ 1.000, SEM = 1.15)。功能能力量表(FAS)也具有良好的重测信度(ICC3,1 = 0.945, 95% CI = 0.861-0.978, SEM = 0.12)和量表间信度(ICC2,1 = 0.973, 95% CI = 0.944-0.989, SEM = 0.18)。内部一致性(IC)使用整体Cronbach's alpha计算,表现出显著的一致性,表现时间(s)和FAS分别为0.99和0.94;最小可检测变化(MDC95)值分别为2.26秒和0.34秒。效度与FMA-UE和SIS-hand函数相关,效度在-0.86 ~ -0.52之间,效度在0.65 ~ 0.80之间。结论:SWMFT-C是一种有效、可靠的慢性脑卒中临床检测仪器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Malaysian Journal of Medical Sciences
Malaysian Journal of Medical Sciences MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
2.70
自引率
0.00%
发文量
89
审稿时长
9 weeks
期刊介绍: The Malaysian Journal of Medical Sciences (MJMS) is a peer-reviewed, open-access, fully online journal that is published at least six times a year. The journal’s scope encompasses all aspects of medical sciences including biomedical, allied health, clinical and social sciences. We accept high quality papers from basic to translational research especially from low & middle income countries, as classified by the United Nations & World Bank (https://datahelpdesk.worldbank.org/knowledgebase/ articles/906519), with the aim that published research will benefit back the bottom billion population from these countries. Manuscripts submitted from developed or high income countries to MJMS must contain data and information that will benefit the socio-health and bio-medical sciences of these low and middle income countries. The MJMS editorial board consists of internationally regarded clinicians and scientists from low and middle income countries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信