Measuring cerebrovascular reactivity with breath-hold fMRI in patients with Moyamoya angiopathy: MR perfusion based delay correction significantly improves agreement to [15O]water PET.
Leonie Zerweck, Uwe Klose, Constantin Roder, Deborah Staber, Emely Renger, Ganna Blazhenets, Kathrin Grundmann-Hauser, Philipp T Meyer, Ulrike Ernemann, Till-Karsten Hauser
{"title":"Measuring cerebrovascular reactivity with breath-hold fMRI in patients with Moyamoya angiopathy: MR perfusion based delay correction significantly improves agreement to [<sup>15</sup>O]water PET.","authors":"Leonie Zerweck, Uwe Klose, Constantin Roder, Deborah Staber, Emely Renger, Ganna Blazhenets, Kathrin Grundmann-Hauser, Philipp T Meyer, Ulrike Ernemann, Till-Karsten Hauser","doi":"10.1007/s00234-025-03649-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Breath-hold functional MRI (bh-fMRI) is able to quantify cerebrovascular reactivity. Vessel stenoses can lead to delayed hemodynamic responses. We aimed to investigate whether delay correction improves the quality of bh-fMRI compared to the diagnostic standard [<sup>15</sup>O]water PET.</p><p><strong>Methods: </strong>The bh-fMRI data sets of 25 patients with Moyamoya Angiopathy were analyzed retrospectively without and with delay correction. Delay correction was calculated using time-to-peak (TTP) maps derived from dynamic susceptibility contrast (DSC) perfusion MRI. [<sup>15</sup>O]water PET maps and bh-fMRI maps without and with delay correction were presented blinded for delay correction to two neuroradiologists. The agreement between bh-fMRI without and with delay correction and [<sup>15</sup>O]water PET was independently and consensually rated on a 4-point-Likert scale (1 = poor, 2 = moderate, 3 = good, 4 = excellent) and compared with Wilcoxon signed-rank test.</p><p><strong>Results: </strong>The agreement between bh-fMRI and [<sup>15</sup>O]water PET without delay correction was good/excellent (median = 3, modus = 4), and improved significantly after delay correction with medium effect size (median = 4, modus = 4, z = -2.121, p = 0.034, r = 0.42).</p><p><strong>Conclusion: </strong>Delay correction improves the quality of bh-fMRI and seems to be helpful in clinical practice.</p>","PeriodicalId":19422,"journal":{"name":"Neuroradiology","volume":" ","pages":"2121-2129"},"PeriodicalIF":2.6000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00234-025-03649-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/5/24 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Breath-hold functional MRI (bh-fMRI) is able to quantify cerebrovascular reactivity. Vessel stenoses can lead to delayed hemodynamic responses. We aimed to investigate whether delay correction improves the quality of bh-fMRI compared to the diagnostic standard [15O]water PET.
Methods: The bh-fMRI data sets of 25 patients with Moyamoya Angiopathy were analyzed retrospectively without and with delay correction. Delay correction was calculated using time-to-peak (TTP) maps derived from dynamic susceptibility contrast (DSC) perfusion MRI. [15O]water PET maps and bh-fMRI maps without and with delay correction were presented blinded for delay correction to two neuroradiologists. The agreement between bh-fMRI without and with delay correction and [15O]water PET was independently and consensually rated on a 4-point-Likert scale (1 = poor, 2 = moderate, 3 = good, 4 = excellent) and compared with Wilcoxon signed-rank test.
Results: The agreement between bh-fMRI and [15O]water PET without delay correction was good/excellent (median = 3, modus = 4), and improved significantly after delay correction with medium effect size (median = 4, modus = 4, z = -2.121, p = 0.034, r = 0.42).
Conclusion: Delay correction improves the quality of bh-fMRI and seems to be helpful in clinical practice.
期刊介绍:
Neuroradiology aims to provide state-of-the-art medical and scientific information in the fields of Neuroradiology, Neurosciences, Neurology, Psychiatry, Neurosurgery, and related medical specialities. Neuroradiology as the official Journal of the European Society of Neuroradiology receives submissions from all parts of the world and publishes peer-reviewed original research, comprehensive reviews, educational papers, opinion papers, and short reports on exceptional clinical observations and new technical developments in the field of Neuroimaging and Neurointervention. The journal has subsections for Diagnostic and Interventional Neuroradiology, Advanced Neuroimaging, Paediatric Neuroradiology, Head-Neck-ENT Radiology, Spine Neuroradiology, and for submissions from Japan. Neuroradiology aims to provide new knowledge about and insights into the function and pathology of the human nervous system that may help to better diagnose and treat nervous system diseases. Neuroradiology is a member of the Committee on Publication Ethics (COPE) and follows the COPE core practices. Neuroradiology prefers articles that are free of bias, self-critical regarding limitations, transparent and clear in describing study participants, methods, and statistics, and short in presenting results. Before peer-review all submissions are automatically checked by iThenticate to assess for potential overlap in prior publication.