Daniel Weiss, Kai Jannusch, Reinhard Meier, Elmar Spüntrup, De-Hua Chang, Farid Ziayee, Lena Marie Wilms, Bernd Turowski, Gerald Antoch, Peter Minko
{"title":"Multicenter experience with a novel flow diverter in visceral aneurysms.","authors":"Daniel Weiss, Kai Jannusch, Reinhard Meier, Elmar Spüntrup, De-Hua Chang, Farid Ziayee, Lena Marie Wilms, Bernd Turowski, Gerald Antoch, Peter Minko","doi":"10.1055/a-2599-0801","DOIUrl":null,"url":null,"abstract":"<p><p>Therapeutic options for the treatment of visceral artery aneurysms (VAA) and pseudoaneurysms (VAPA) include either a surgical or endovascular approach, depending on specific characteristics of both the aneurysm and the individual patient. The therapeutic use of flow diverters (FD) has already yielded excellent results. The purpose of this study is to evaluate initial experiences regarding the use of a novel abdominal FD.In this observational multicenter study, the data of nine consecutive patients with visceral or abdominal aneurysms from four interventional centers, treated with the Derivo peripher FD, between 2022 and 2024 were evaluated regarding the technical feasibility and procedural performance of the device, safety, and treatment outcome.The average size of the treated aneurysms was 18±11 mm, and the affected vessels were the splenic (55.6%), the hepatic (22.2%), the gastroduodenal (11.1%), and the renal artery (11.1%). Complete aneurysm occlusion was observed in every patient after three months, and mid-term follow-up after 12 months was available for eight patients. All FDs remained patent during the follow-up period. No major complications or adverse events arose. The overall mortality rate was 0%.Based on our initial multicenter experience, endovascular treatment of abdominal and visceral aneurysms with an FD was found to be effective and safe. The remarkable results in terms of aneurysm occlusion and low complication rates are promising. · The flow diverter was highly effective, achieving complete aneurysm occlusion in all treated patients.. · The procedure had an excellent safety profile, with no major complications, adverse events, or mortality reported and with patency in the follow-up.. · This initial multicenter experience highlights the potential of this endovascular approach as an alternative to traditional surgical methods for managing abdominal and visceral aneurysms.. · Weiss D, Jannusch K, Meier R et al. Multicenter experience with a novel flow diverter in visceral aneurysms. Rofo 2025; DOI 10.1055/a-2599-0801.</p>","PeriodicalId":21490,"journal":{"name":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2599-0801","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Therapeutic options for the treatment of visceral artery aneurysms (VAA) and pseudoaneurysms (VAPA) include either a surgical or endovascular approach, depending on specific characteristics of both the aneurysm and the individual patient. The therapeutic use of flow diverters (FD) has already yielded excellent results. The purpose of this study is to evaluate initial experiences regarding the use of a novel abdominal FD.In this observational multicenter study, the data of nine consecutive patients with visceral or abdominal aneurysms from four interventional centers, treated with the Derivo peripher FD, between 2022 and 2024 were evaluated regarding the technical feasibility and procedural performance of the device, safety, and treatment outcome.The average size of the treated aneurysms was 18±11 mm, and the affected vessels were the splenic (55.6%), the hepatic (22.2%), the gastroduodenal (11.1%), and the renal artery (11.1%). Complete aneurysm occlusion was observed in every patient after three months, and mid-term follow-up after 12 months was available for eight patients. All FDs remained patent during the follow-up period. No major complications or adverse events arose. The overall mortality rate was 0%.Based on our initial multicenter experience, endovascular treatment of abdominal and visceral aneurysms with an FD was found to be effective and safe. The remarkable results in terms of aneurysm occlusion and low complication rates are promising. · The flow diverter was highly effective, achieving complete aneurysm occlusion in all treated patients.. · The procedure had an excellent safety profile, with no major complications, adverse events, or mortality reported and with patency in the follow-up.. · This initial multicenter experience highlights the potential of this endovascular approach as an alternative to traditional surgical methods for managing abdominal and visceral aneurysms.. · Weiss D, Jannusch K, Meier R et al. Multicenter experience with a novel flow diverter in visceral aneurysms. Rofo 2025; DOI 10.1055/a-2599-0801.
期刊介绍:
Die RöFo veröffentlicht Originalarbeiten, Übersichtsartikel und Fallberichte aus dem Bereich der Radiologie und den weiteren bildgebenden Verfahren in der Medizin. Es dürfen nur Arbeiten eingereicht werden, die noch nicht veröffentlicht sind und die auch nicht gleichzeitig einer anderen Zeitschrift zur Veröffentlichung angeboten wurden. Alle eingereichten Beiträge unterliegen einer sorgfältigen fachlichen Begutachtung.
Gegründet 1896 – nur knapp 1 Jahr nach der Entdeckung der Röntgenstrahlen durch C.W. Röntgen – blickt die RöFo auf über 100 Jahre Erfahrung als wichtigstes Publikationsmedium in der deutschsprachigen Radiologie zurück. Sie ist damit die älteste radiologische Fachzeitschrift und schafft es erfolgreich, lange Kontinuität mit dem Anspruch an wissenschaftliches Publizieren auf internationalem Niveau zu verbinden. Durch ihren zentralen Platz im Verlagsprogramm stellte die RöFo die Basis für das heute umfassende und erfolgreiche Radiologie-Medienangebot im Georg Thieme Verlag.
Besonders eng verbunden ist die RöFo mit der Geschichte der Röntgengesellschaften in Deutschland und Österreich. Sie ist offizielles Organ von DRG und ÖRG und die Mitglieder der Fachgesellschaften erhalten die Zeitschrift im Rahmen ihrer Mitgliedschaft. Mit ihrem wissenschaftlichen Kernteil und dem eigenen Mitteilungsteil der Fachgesellschaften bietet die RöFo Monat für Monat ein Forum für den Austausch von Inhalten und Botschaften der radiologischen Community im deutschsprachigen Raum.