Development and optimization of human deuterium MR spectroscopic imaging at 3 T in the abdomen.

IF 3 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Mary A McLean, Ines Horvat Menih, Pascal Wodtke, Joshua D Kaggie, Jonathan R Birchall, Rolf F Schulte, Ashley Grimmer, Elizabeth Latimer, Marta Wylot, Maria J Zamora Morales, Alixander S Khan, Huanjun Wang, James Armitage, Thomas J Mitchell, Grant D Stewart, Ferdia A Gallagher
{"title":"Development and optimization of human deuterium MR spectroscopic imaging at 3 T in the abdomen.","authors":"Mary A McLean, Ines Horvat Menih, Pascal Wodtke, Joshua D Kaggie, Jonathan R Birchall, Rolf F Schulte, Ashley Grimmer, Elizabeth Latimer, Marta Wylot, Maria J Zamora Morales, Alixander S Khan, Huanjun Wang, James Armitage, Thomas J Mitchell, Grant D Stewart, Ferdia A Gallagher","doi":"10.1002/mrm.30556","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To establish and optimize abdominal deuterium MR spectroscopic imaging in conjunction with orally administered <sup>2</sup>H-labeled molecules.</p><p><strong>Methods: </strong>A flexible transmit-receive surface coil was used to image naturally abundant deuterium signal in phantoms and healthy volunteers and after orally administered <sup>2</sup>H<sub>2</sub>O in a patient with a benign renal tumor (oncocytoma).</p><p><strong>Results: </strong>Water and lipid peaks were fitted with high confidence from both unlocalized spectra and from voxels within the liver, kidney, and spleen on spectroscopic imaging. Artifacts were minimal, despite the high <sup>2</sup>H<sub>2</sub>O concentration in the stomach immediately after ingestion, which can be problematic with the use of a volume coil.</p><p><strong>Conclusion: </strong>We have shown the feasibility of abdominal deuterium MR spectroscopic imaging at 3 T using a flexible surface coil. Water measurements were obtained in healthy volunteers, and images were acquired in a patient with a renal tumor after drinking <sup>2</sup>H<sub>2</sub>O. The limited depth penetration of the surface coil may have advantages in characterizing early uptake of orally administered agents in abdominal organs, despite the high concentrations in the stomach which can pose challenges with other coil combinations.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.30556","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To establish and optimize abdominal deuterium MR spectroscopic imaging in conjunction with orally administered 2H-labeled molecules.

Methods: A flexible transmit-receive surface coil was used to image naturally abundant deuterium signal in phantoms and healthy volunteers and after orally administered 2H2O in a patient with a benign renal tumor (oncocytoma).

Results: Water and lipid peaks were fitted with high confidence from both unlocalized spectra and from voxels within the liver, kidney, and spleen on spectroscopic imaging. Artifacts were minimal, despite the high 2H2O concentration in the stomach immediately after ingestion, which can be problematic with the use of a volume coil.

Conclusion: We have shown the feasibility of abdominal deuterium MR spectroscopic imaging at 3 T using a flexible surface coil. Water measurements were obtained in healthy volunteers, and images were acquired in a patient with a renal tumor after drinking 2H2O. The limited depth penetration of the surface coil may have advantages in characterizing early uptake of orally administered agents in abdominal organs, despite the high concentrations in the stomach which can pose challenges with other coil combinations.

腹部3t人体氘磁共振光谱成像技术的开发与优化。
目的:建立并优化腹腔氘核磁共振成像与口服2h标记分子的结合。方法:采用柔性发射-接收表面线圈,对鬼怪和健康志愿者以及良性肾肿瘤(嗜瘤)患者口服2H2O后自然丰富的氘信号进行成像。结果:在非定域光谱和肝、肾、脾的体素光谱成像中,水和脂质峰具有高置信度拟合。尽管在摄入后胃中立即出现高浓度的2H2O,但伪影很小,这可能会给使用容积线圈带来问题。结论:我们证明了使用柔性表面线圈在3t下进行腹部氘磁共振光谱成像的可行性。对健康志愿者进行了水分测量,并对饮用2H2O的肾肿瘤患者进行了图像采集。表面线圈的有限深度穿透可能在表征口服给药药物在腹部器官的早期摄取方面具有优势,尽管胃中的高浓度可能对其他线圈组合构成挑战。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信