Color Stability of Orthodontic Elastomeric Ligatures in the Oral Environment: A Clinical Trial.

Q3 Dentistry
Frontiers in Dentistry Pub Date : 2025-01-13 eCollection Date: 2025-01-01 DOI:10.18502/fid.v22i3.17542
Marzieh Mazhari, Mehdi Yaghoubi Ashrafi, Sara Gholamian, Mehrnaz Moradinejad
{"title":"Color Stability of Orthodontic Elastomeric Ligatures in the Oral Environment: A Clinical Trial.","authors":"Marzieh Mazhari, Mehdi Yaghoubi Ashrafi, Sara Gholamian, Mehrnaz Moradinejad","doi":"10.18502/fid.v22i3.17542","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objectives:</b> Despite the recent advances in orthodontic appliances, color change of elastomeric ligatures over time remains a problem causing patient dissatisfaction. This study aimed to assess the color stability of different types of orthodontic elastomeric ligatures in the oral environment. <b>Materials and Methods:</b> This clinical trial was conducted on 67 patients. After applying the exclusion criteria, 11 participants were excluded, and 56 remained. Four different brands of elastomeric ligatures namely Ortho Technology, Ortho Organizers, American Orthodontics, and SIA were randomly used in the four quadrants of each patient (n=14 from each brand). Discoloration of ligatures was scored in the oral cavity by orthodontists and patients on the day of placement (T0) and 28 days later (T1). Photography and CIE L*a*b* color space were used to assess the color change (∆E). Data were analyzed by the Kruskal-Wallis and Bonferroni tests. <b>Results:</b> All brands showed discoloration. The highest ∆E was identified in SIA and Ortho Technology, while the lowest was recorded in Ortho Organizers. The lowest ∆b (yellowness) and the greatest reduction in L* (lightness) and ∆a (redness) were observed in Ortho Organizers. According to the opinion of patients and orthodontists at T0 and T1, SIA was the least visible followed by Ortho Technology. No significant difference was found between orthodontists and patients at T0 and T1 regarding the visibility of ligatures (P>0.05). <b>Conclusion:</b> After 28 days, all brands of elastomeric ligatures showed considerable discoloration. Ortho Organizers showed the highest color stability.</p>","PeriodicalId":12445,"journal":{"name":"Frontiers in Dentistry","volume":"22 ","pages":"3"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12085874/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/fid.v22i3.17542","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Despite the recent advances in orthodontic appliances, color change of elastomeric ligatures over time remains a problem causing patient dissatisfaction. This study aimed to assess the color stability of different types of orthodontic elastomeric ligatures in the oral environment. Materials and Methods: This clinical trial was conducted on 67 patients. After applying the exclusion criteria, 11 participants were excluded, and 56 remained. Four different brands of elastomeric ligatures namely Ortho Technology, Ortho Organizers, American Orthodontics, and SIA were randomly used in the four quadrants of each patient (n=14 from each brand). Discoloration of ligatures was scored in the oral cavity by orthodontists and patients on the day of placement (T0) and 28 days later (T1). Photography and CIE L*a*b* color space were used to assess the color change (∆E). Data were analyzed by the Kruskal-Wallis and Bonferroni tests. Results: All brands showed discoloration. The highest ∆E was identified in SIA and Ortho Technology, while the lowest was recorded in Ortho Organizers. The lowest ∆b (yellowness) and the greatest reduction in L* (lightness) and ∆a (redness) were observed in Ortho Organizers. According to the opinion of patients and orthodontists at T0 and T1, SIA was the least visible followed by Ortho Technology. No significant difference was found between orthodontists and patients at T0 and T1 regarding the visibility of ligatures (P>0.05). Conclusion: After 28 days, all brands of elastomeric ligatures showed considerable discoloration. Ortho Organizers showed the highest color stability.

口腔环境下正畸弹性结扎颜色稳定性的临床研究。
目的:尽管近年来在正畸矫治器的进步,随着时间的推移,弹性结扎颜色的变化仍然是一个问题,引起患者的不满。本研究旨在评估不同类型的正畸弹性结扎在口腔环境下的颜色稳定性。材料与方法:对67例患者进行临床试验。应用排除标准后,11名受试者被排除,56名受试者被保留。每个患者的四个象限随机使用四个不同品牌的弹性结扎,分别是Ortho Technology、Ortho organizer、American Orthodontics和SIA(每个品牌n=14)。正畸医师和患者分别在放置当天(T0)和28天后(T1)对结扎物在口腔内的变色情况进行评分。采用摄影和CIE L*a*b*色彩空间评价颜色变化(∆E)。数据通过Kruskal-Wallis和Bonferroni测试进行分析。结果:各品牌均有变色现象。SIA和Ortho Technology的∆E最高,而Ortho organizer的∆E最低。Ortho组织者观察到最低的∆b(黄色)和最大的L*(亮度)和∆a(红色)的减少。根据T0和T1时患者和正畸医生的意见,SIA是最不明显的,其次是Ortho Technology。正畸医师与患者在T0、T1结扎可见性差异无统计学意义(P < 0.05)。结论:28天后,所有品牌的橡皮筋结扎均出现明显的变色。Ortho organizer显示出最高的颜色稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Frontiers in Dentistry
Frontiers in Dentistry Dentistry-General Dentistry
CiteScore
1.00
自引率
0.00%
发文量
34
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信