{"title":"Green and sustainable LC-APCI-MS/MS method for simultaneous quantification of genotoxic nitrosamines in antidiabetic medication: sitagliptin","authors":"Sriram Pepakayala, Venkata Nadh Ratnakaram, Yuvaraj Zunjarrao, Yogesh Kumar Lohia","doi":"10.1186/s13065-025-01503-4","DOIUrl":null,"url":null,"abstract":"<p>The International Agency for Research on Cancer categorized nitrosamines as potential or probable human carcinogens. Hence, nitrosamine impurities should be controlled to minimize the cancer risk. Sustainable Development Goal 9 (SDG9: Industry, Innovation, and Infrastructure), Target 9.4 was realized by developing a simple and straightforward LC-APCI-MS/MS method for simultaneous determination of potential nitrosamines: N-nitroso dimethylamine, N-nitroso di isopropyl amine, N-nitroso isopropyl ethylamine and N-nitroso methyl aminopyridine (NDMA, NDIPA, NIPEA and NMAP) in Sitagliptin Phosphate Monohydrate API (STG-API), an antidiabetic medication for type-2 diabetes and validated as per ICH (Q2 R2) guidelines. As a part of SDG9 (Industry, Innovation, and Infrastructure), Target 9.4, greater adoption of clean and environmentally sound technologies is possible by using the current analytical method in view of (a) less consumption of solvents as it has a lower run time of 18 min (b) at-line sample collection (c) simple sample preparation (d) sample preparation process that does not require derivatization or sample extraction. The optimized LC method conditions are an Agilent Poroshell EC C18 column, a flow rate of 0.6 mL/min, an injection volume of 40 µL, a column oven temperature set at 50 °C, and a sample cooler temperature set at 6 °C. A gradient method was adopted using a mixture of mobile phases (Solvent A: 0.1% formic acid in water and Solvent B: a mixture of 50% Methanol and 50% Acetonitrile). The response was obtained with Multiple Reaction Monitoring (MRM) in APCI mode. The current method can quantify NDMA, NIPEA, NDIPA, and NMAP to a lower level of 74.19 ng/g, 19.62 ng/g, 20.36 ng/g, and 13.65 ng/g, respectively, which is less than 10% of the specified limits. Good linearity in the range of Limit of Quantitation (LOQ) to 150% of the specification limit was observed, with correlation coefficients higher than 0.996. The recoveries were over the range between 90.23 and 103.36%. Assessed the method’s eco-friendliness by greenness tools like the Modified Green Analytical Procedure Index (MoGAPI), ComplexMoGAPI, Analytical GREEnness (AGREE), and Analytical Eco-Scale, and found it to be eco-friendly.</p>","PeriodicalId":496,"journal":{"name":"BMC Chemistry","volume":"19 1","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://bmcchem.biomedcentral.com/counter/pdf/10.1186/s13065-025-01503-4","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1186/s13065-025-01503-4","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
The International Agency for Research on Cancer categorized nitrosamines as potential or probable human carcinogens. Hence, nitrosamine impurities should be controlled to minimize the cancer risk. Sustainable Development Goal 9 (SDG9: Industry, Innovation, and Infrastructure), Target 9.4 was realized by developing a simple and straightforward LC-APCI-MS/MS method for simultaneous determination of potential nitrosamines: N-nitroso dimethylamine, N-nitroso di isopropyl amine, N-nitroso isopropyl ethylamine and N-nitroso methyl aminopyridine (NDMA, NDIPA, NIPEA and NMAP) in Sitagliptin Phosphate Monohydrate API (STG-API), an antidiabetic medication for type-2 diabetes and validated as per ICH (Q2 R2) guidelines. As a part of SDG9 (Industry, Innovation, and Infrastructure), Target 9.4, greater adoption of clean and environmentally sound technologies is possible by using the current analytical method in view of (a) less consumption of solvents as it has a lower run time of 18 min (b) at-line sample collection (c) simple sample preparation (d) sample preparation process that does not require derivatization or sample extraction. The optimized LC method conditions are an Agilent Poroshell EC C18 column, a flow rate of 0.6 mL/min, an injection volume of 40 µL, a column oven temperature set at 50 °C, and a sample cooler temperature set at 6 °C. A gradient method was adopted using a mixture of mobile phases (Solvent A: 0.1% formic acid in water and Solvent B: a mixture of 50% Methanol and 50% Acetonitrile). The response was obtained with Multiple Reaction Monitoring (MRM) in APCI mode. The current method can quantify NDMA, NIPEA, NDIPA, and NMAP to a lower level of 74.19 ng/g, 19.62 ng/g, 20.36 ng/g, and 13.65 ng/g, respectively, which is less than 10% of the specified limits. Good linearity in the range of Limit of Quantitation (LOQ) to 150% of the specification limit was observed, with correlation coefficients higher than 0.996. The recoveries were over the range between 90.23 and 103.36%. Assessed the method’s eco-friendliness by greenness tools like the Modified Green Analytical Procedure Index (MoGAPI), ComplexMoGAPI, Analytical GREEnness (AGREE), and Analytical Eco-Scale, and found it to be eco-friendly.
期刊介绍:
BMC Chemistry, formerly known as Chemistry Central Journal, is now part of the BMC series journals family.
Chemistry Central Journal has served the chemistry community as a trusted open access resource for more than 10 years – and we are delighted to announce the next step on its journey. In January 2019 the journal has been renamed BMC Chemistry and now strengthens the BMC series footprint in the physical sciences by publishing quality articles and by pushing the boundaries of open chemistry.