{"title":"Traditional and adaptive speech audiometry in single-sided deaf (SSD) subjects rehabilitated by bone conductive implants (BCI), quality of life and long-term utilization.","authors":"Edoardo Covelli, Chiara Filippi, Francesco Lazzerini, Elisabetta Tromboni, Silvia Tarentini, Sofia Pizzolante, Francesca Forli, Stefano Berrettini, Luca Bruschini","doi":"10.1080/00016489.2025.2504032","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Single-sided deafness (SSD) encompasses the presence of a profoundly deaf ear with a normal, contralateral one. Patients with SSD may have difficulty with speech intelligibility in noise and localizing sounds.</p><p><strong>Aims/objectives: </strong>This retrospective study aims to evaluate the long-term effectiveness of bone conduction implant (BCI) in a group of patients with SSD.</p><p><strong>Material and methods: </strong>Audiologic benefit was assessed through conventional speech audiometry and adaptive Matrix test. Impact on quality of life was evaluated with the Glasgow Benefit Inventory (GBI) questionnaire. BCI usage data were also obtained from each subject.</p><p><strong>Results: </strong>Thirty-two patients were included. No statistically significant improvements were found at standard audiometric tests using BCI, but at Matrix test the mean SRT is reached at S/N -1.16 dB without BCI and -2.07 with BCI with a statistically significant difference (<i>p</i> = 0.026). The mean GBI score was 25.12, ranging from -8.3 to 47.2. Ten subjects (31%) discontinued the BCI use overtime.</p><p><strong>Conclusions and significance: </strong>Benefit assessment of BCI in SSD recipients can be difficult. Adaptive audiometric test could be useful. Quality of life measures seem to suggest potential 'beyond-auditory' benefits. SSD recipients can be inconsistent users of BCI.</p>","PeriodicalId":6880,"journal":{"name":"Acta Oto-Laryngologica","volume":" ","pages":"1-7"},"PeriodicalIF":1.2000,"publicationDate":"2025-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Oto-Laryngologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00016489.2025.2504032","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Single-sided deafness (SSD) encompasses the presence of a profoundly deaf ear with a normal, contralateral one. Patients with SSD may have difficulty with speech intelligibility in noise and localizing sounds.

Aims/objectives: This retrospective study aims to evaluate the long-term effectiveness of bone conduction implant (BCI) in a group of patients with SSD.

Material and methods: Audiologic benefit was assessed through conventional speech audiometry and adaptive Matrix test. Impact on quality of life was evaluated with the Glasgow Benefit Inventory (GBI) questionnaire. BCI usage data were also obtained from each subject.

Results: Thirty-two patients were included. No statistically significant improvements were found at standard audiometric tests using BCI, but at Matrix test the mean SRT is reached at S/N -1.16 dB without BCI and -2.07 with BCI with a statistically significant difference (p = 0.026). The mean GBI score was 25.12, ranging from -8.3 to 47.2. Ten subjects (31%) discontinued the BCI use overtime.

Conclusions and significance: Benefit assessment of BCI in SSD recipients can be difficult. Adaptive audiometric test could be useful. Quality of life measures seem to suggest potential 'beyond-auditory' benefits. SSD recipients can be inconsistent users of BCI.

单侧耳聋经骨传导植入(BCI)康复者的传统和自适应语音测听、生活质量和长期使用。
背景:单侧耳聋(SSD)包括一个对侧正常耳朵的深度耳聋。SSD患者可能在噪音和声音定位方面存在语音清晰度困难。目的/目的:本回顾性研究旨在评估骨传导植入(BCI)在一组SSD患者中的长期疗效。材料和方法:采用常规语音测听法和自适应矩阵法评价听力效益。用格拉斯哥福利量表(GBI)评估对生活质量的影响。同时获得每个受试者的脑机接口使用数据。结果:纳入32例患者。在使用BCI的标准听力测试中,没有发现有统计学意义的改善,但在Matrix测试中,无BCI的平均SRT达到-1.16 dB, BCI达到-2.07,差异有统计学意义(p = 0.026)。GBI平均评分为25.12,范围从-8.3到47.2。10名受试者(31%)超时停止脑机接口使用。结论与意义:SSD受者脑机接口的获益评估是困难的。适应性听力测试可能有用。生活质量指标似乎显示了潜在的“听觉之外”的好处。SSD收件人可以是BCI的不一致用户。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta Oto-Laryngologica
Acta Oto-Laryngologica 医学-耳鼻喉科学
CiteScore
2.50
自引率
0.00%
发文量
99
审稿时长
3-6 weeks
期刊介绍: Acta Oto-Laryngologica is a truly international journal for translational otolaryngology and head- and neck surgery. The journal presents cutting-edge papers on clinical practice, clinical research and basic sciences. Acta also bridges the gap between clinical and basic research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信