The association between corneal immune cell dynamics and comfort in silicone hydrogel contact lens wearers.

IF 4.1 3区 医学 Q1 OPHTHALMOLOGY
Laura Valencia-Nieto, Katie Edwards, Azadeh Tavakoli, María J González-García, Alberto López-Miguel, Samantha Dando, Alex Hui, Maria Markoulli, Eric B Papas, Luisa H Colorado
{"title":"The association between corneal immune cell dynamics and comfort in silicone hydrogel contact lens wearers.","authors":"Laura Valencia-Nieto, Katie Edwards, Azadeh Tavakoli, María J González-García, Alberto López-Miguel, Samantha Dando, Alex Hui, Maria Markoulli, Eric B Papas, Luisa H Colorado","doi":"10.1016/j.clae.2025.102424","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To study the association between corneal immune cell dynamics and contact lens (CL) comfort, as well as tear film inflammatory mediators in established CL wearers.</p><p><strong>Methods: </strong>A prospective, cross-sectional study including existing CL wearers was conducted. Symptoms were assessed with a comfort visual analog scale (VAS) and the Contact Lens Dry Eye Questionnaire-8. In-vivo corneal confocal microscopy was used to track immune cell dynamics over 3 timepoints at 5-minute intervals. Trajectory speed was calculated as the total length travelled by cells divided by time; displacement speed as the straight-line distance between the start and end positions of a cell divided by time; and persistence ratio as the ratio of displacement speed and trajectory speed. Measurements were performed for 1-3 cells per participant, and the minimum, maximum, and average values were analyzed. Tear film samples were collected to assess matrix metalloproteinase (MMP)-9, tissue inhibitor of metalloproteinase (TIMP)-1, and the MMP-9/TIMP-1 ratio. Correlations between immune cell dynamics, symptoms, and tear inflammatory mediators, were analyzed.</p><p><strong>Results: </strong>Nineteen CL wearers (4 men and 15 women) aged 30 ± 5 years were included. Participants wore silicone hydrogel CLs for 8-10 h before clinical assessment. There was a significant association between comfort VAS and the maximum (rho = 0.533; p = 0.019) and average (rho = 0.506; p = 0.027) values of immune cell displacement speed. The concentration of MMP-9 was associated with the minimum value of trajectory speed (rho = 0.621; p = 0.031). Finally, the MMP-9/TIMP-1 ratio was associated with the maximum value of trajectory speed (rho = -0.717; p = 0.030), and the maximum (rho = -0.720; p = 0.008) and average (rho = -0.678; p = 0.015) values of displacement speed.</p><p><strong>Conclusion: </strong>Corneal immune cell dynamics is related to sensations of discomfort in silicone hydrogel CL wearers, with cell speed possibly being regulated by inflammatory mediators assessed from the tear film. These observations may aid in understanding the mechanisms underlying the discomfort response.</p>","PeriodicalId":49087,"journal":{"name":"Contact Lens & Anterior Eye","volume":" ","pages":"102424"},"PeriodicalIF":4.1000,"publicationDate":"2025-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contact Lens & Anterior Eye","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.clae.2025.102424","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To study the association between corneal immune cell dynamics and contact lens (CL) comfort, as well as tear film inflammatory mediators in established CL wearers.

Methods: A prospective, cross-sectional study including existing CL wearers was conducted. Symptoms were assessed with a comfort visual analog scale (VAS) and the Contact Lens Dry Eye Questionnaire-8. In-vivo corneal confocal microscopy was used to track immune cell dynamics over 3 timepoints at 5-minute intervals. Trajectory speed was calculated as the total length travelled by cells divided by time; displacement speed as the straight-line distance between the start and end positions of a cell divided by time; and persistence ratio as the ratio of displacement speed and trajectory speed. Measurements were performed for 1-3 cells per participant, and the minimum, maximum, and average values were analyzed. Tear film samples were collected to assess matrix metalloproteinase (MMP)-9, tissue inhibitor of metalloproteinase (TIMP)-1, and the MMP-9/TIMP-1 ratio. Correlations between immune cell dynamics, symptoms, and tear inflammatory mediators, were analyzed.

Results: Nineteen CL wearers (4 men and 15 women) aged 30 ± 5 years were included. Participants wore silicone hydrogel CLs for 8-10 h before clinical assessment. There was a significant association between comfort VAS and the maximum (rho = 0.533; p = 0.019) and average (rho = 0.506; p = 0.027) values of immune cell displacement speed. The concentration of MMP-9 was associated with the minimum value of trajectory speed (rho = 0.621; p = 0.031). Finally, the MMP-9/TIMP-1 ratio was associated with the maximum value of trajectory speed (rho = -0.717; p = 0.030), and the maximum (rho = -0.720; p = 0.008) and average (rho = -0.678; p = 0.015) values of displacement speed.

Conclusion: Corneal immune cell dynamics is related to sensations of discomfort in silicone hydrogel CL wearers, with cell speed possibly being regulated by inflammatory mediators assessed from the tear film. These observations may aid in understanding the mechanisms underlying the discomfort response.

硅水凝胶隐形眼镜佩戴者角膜免疫细胞动力学与舒适度之间的关系。
目的:探讨角膜接触镜配戴者角膜免疫细胞动力学与角膜接触镜舒适度及泪膜炎症介质的关系。方法:前瞻性横断面研究,包括现有的佩戴者。采用舒适视觉模拟量表(VAS)和隐形眼镜干眼症问卷-8对症状进行评估。在体内角膜共聚焦显微镜跟踪免疫细胞动力学超过3个时间点,每5分钟的间隔。轨迹速度计算为细胞移动的总长度除以时间;位移速度为单元格起始和结束位置之间的直线距离除以时间;持久比为位移速度与轨迹速度之比。对每个参与者进行1-3个细胞的测量,并分析最小值、最大值和平均值。收集泪膜样品,评估基质金属蛋白酶(MMP)-9、组织金属蛋白酶抑制剂(TIMP)-1及MMP-9/TIMP-1比值。分析了免疫细胞动力学、症状和泪液炎症介质之间的相关性。结果:共纳入CL患者19例(男4例,女15例),年龄30±5岁。参与者在临床评估前佩戴硅胶水凝胶CLs 8-10小时。舒适度VAS与最大评分有显著相关性(rho = 0.533;P = 0.019)和平均值(rho = 0.506;P = 0.027)值。MMP-9浓度与轨迹速度最小值相关(rho = 0.621;p = 0.031)。最后,MMP-9/TIMP-1比值与轨迹速度最大值相关(rho = -0.717;P = 0.030),最大值(rho = -0.720;P = 0.008)和平均值(rho = -0.678;P = 0.015)值。结论:角膜免疫细胞动力学与硅酮水凝胶CL佩戴者的不适感有关,细胞速度可能是由泪膜评估的炎症介质调节的。这些观察结果可能有助于理解不适反应的机制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.60
自引率
18.80%
发文量
198
审稿时长
55 days
期刊介绍: Contact Lens & Anterior Eye is a research-based journal covering all aspects of contact lens theory and practice, including original articles on invention and innovations, as well as the regular features of: Case Reports; Literary Reviews; Editorials; Instrumentation and Techniques and Dates of Professional Meetings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信