AccuVein® versus traditional clinical methods in successful intravenous catheterization in adults: a randomized trial protocol.

Q3 Nursing
Revista gaucha de enfermagem / EENFUFRGS Pub Date : 2025-05-12 eCollection Date: 2025-01-01 DOI:10.1590/1983-1447.2025.20240146.en
Isaiane Santos Bittencourt, Luciano Marques Dos Santos, Denise Miyuki Kusahara, Ariane Ferreira Machado Avelar
{"title":"AccuVein® versus traditional clinical methods in successful intravenous catheterization in adults: a randomized trial protocol.","authors":"Isaiane Santos Bittencourt, Luciano Marques Dos Santos, Denise Miyuki Kusahara, Ariane Ferreira Machado Avelar","doi":"10.1590/1983-1447.2025.20240146.en","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To verify the effectiveness of AccuVeinAV300® in the success of peripheral intravenous catheterization in adults with difficult intravenous access, compared to the traditional clinical method.</p><p><strong>Method: </strong>This is a description of the protocol for a randomized controlled clinical trial in a parallel, non-blinded group. It will be carried out with patients from the medical and surgical clinics of a university hospital. The sample will be determined after a pilot study with 60 patients. Inclusion criteria will be age 18 or above, difficult intravenous access and no clinical deterioration. Participants in the intervention group will undergo peripheral intravenous catheterization with the AccuVeinAV300®, which is a vein viewer with a near-infrared light emitter. For patients in the control group, the procedure will take place using the traditional clinical method, using inspection and palpation. The procedure will be considered successful when the catheter is inserted on the first attempt with blood reflux, as long as it is possible to infuse 10 ml of saline solution without complications. Data collected will include observation of peripheral intravenous catheterization, information collected from the patient, and from medical records. Data analysis will be descriptive, univariate and multiple. RBR-6jm5zht.</p>","PeriodicalId":35609,"journal":{"name":"Revista gaucha de enfermagem / EENFUFRGS","volume":"46 ","pages":"e20240146"},"PeriodicalIF":0.0000,"publicationDate":"2025-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista gaucha de enfermagem / EENFUFRGS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/1983-1447.2025.20240146.en","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Nursing","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To verify the effectiveness of AccuVeinAV300® in the success of peripheral intravenous catheterization in adults with difficult intravenous access, compared to the traditional clinical method.

Method: This is a description of the protocol for a randomized controlled clinical trial in a parallel, non-blinded group. It will be carried out with patients from the medical and surgical clinics of a university hospital. The sample will be determined after a pilot study with 60 patients. Inclusion criteria will be age 18 or above, difficult intravenous access and no clinical deterioration. Participants in the intervention group will undergo peripheral intravenous catheterization with the AccuVeinAV300®, which is a vein viewer with a near-infrared light emitter. For patients in the control group, the procedure will take place using the traditional clinical method, using inspection and palpation. The procedure will be considered successful when the catheter is inserted on the first attempt with blood reflux, as long as it is possible to infuse 10 ml of saline solution without complications. Data collected will include observation of peripheral intravenous catheterization, information collected from the patient, and from medical records. Data analysis will be descriptive, univariate and multiple. RBR-6jm5zht.

AccuVein®与传统临床方法在成人成功静脉导管置入中的比较:一项随机试验方案
目的:对比传统临床方法,验证AccuVeinAV300®在静脉通道困难成人外周静脉置管成功率中的有效性。方法:这是一项平行、非盲组随机对照临床试验的方案描述。它将在大学医院内科和外科诊所的病人中进行。样本将在对60名患者进行初步研究后确定。纳入标准为18岁或以上,静脉注射困难,无临床恶化。干预组的参与者将使用AccuVeinAV300®进行外周静脉置管,这是一种带有近红外光发射器的静脉观察器。对于对照组的患者,该程序将使用传统的临床方法,使用检查和触诊。当第一次尝试插入导管时伴有血液反流,只要能够注入10ml生理盐水而无并发症,则认为手术成功。收集的数据将包括外周静脉置管观察、从患者和医疗记录中收集的信息。数据分析将是描述性的、单变量的和多重的。RBR-6jm5zht。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
118
审稿时长
16 weeks
期刊介绍: A Escola de Enfermagem da Universidade Federal do Rio Grande do Sul edita e publica a Revista Gaúcha de Enfermagem para divulgar a produção científica da Enfermagem e áreas afins. Foi criada em 1976 e atualmente tem periodicidade trimestral.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信