Penetration of Biodentine, NeoMTA 2, and NeoPUTTY into dentinal tubules in primary tooth pulpotomy: a confocal laser scanning microscopy analysis.

IF 2.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Merve Ozdemir, Aysenur Oncu
{"title":"Penetration of Biodentine, NeoMTA 2, and NeoPUTTY into dentinal tubules in primary tooth pulpotomy: a confocal laser scanning microscopy analysis.","authors":"Merve Ozdemir, Aysenur Oncu","doi":"10.1186/s12903-025-06065-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pulpotomy is an accepted treatment option to preserve primary teeth with exposed pulp due to caries or trauma and to ensure proper function until physiologic exfoliation. This study aimed to assess the dentin penetration of NeoMTA 2, NeoPUTTY, and Biodentine using confocal laser scanning microscopy (CLSM).</p><p><strong>Methods: </strong>The present study was performed using 42 freshly extracted lower primary molars. All samples were divided into 3 separate groups and the Biodentine, NeoMTA 2, and NeoPUTTY were placed on the cavity floor, respectively. High-speed diamond discs were used to create 2-mm-thick sections from the furcation region, including a 1- mm crown and 1-mm root. Primary molar tooth sections were placed on a glass slide and examined using a CLSM (LSM 980, Zeiss, Germany). All images were analyzed using ImageJ/Fiji (National Institute of Health, USA) software for the measurement of penetration depth. The penetration depth of the materials was evaluated using one- way ANOVA, and the Tukey test was used for comparisons between groups at p < 0.05 significance level.</p><p><strong>Results: </strong>There was no significant difference in penetration depth between the Biodentine and NeoMTA 2 materials. NeoPUTTY showed higher penetration depth than Biodentine and NeoMTA 2.</p><p><strong>Conclusions: </strong>This study reported that NeoPUTTY showed higher dentinal tubule penetration in primary teeth than NeoMTA 2 and Biodentine as pulpotomy materials.</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"25 1","pages":"727"},"PeriodicalIF":2.6000,"publicationDate":"2025-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12083007/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-025-06065-4","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Pulpotomy is an accepted treatment option to preserve primary teeth with exposed pulp due to caries or trauma and to ensure proper function until physiologic exfoliation. This study aimed to assess the dentin penetration of NeoMTA 2, NeoPUTTY, and Biodentine using confocal laser scanning microscopy (CLSM).

Methods: The present study was performed using 42 freshly extracted lower primary molars. All samples were divided into 3 separate groups and the Biodentine, NeoMTA 2, and NeoPUTTY were placed on the cavity floor, respectively. High-speed diamond discs were used to create 2-mm-thick sections from the furcation region, including a 1- mm crown and 1-mm root. Primary molar tooth sections were placed on a glass slide and examined using a CLSM (LSM 980, Zeiss, Germany). All images were analyzed using ImageJ/Fiji (National Institute of Health, USA) software for the measurement of penetration depth. The penetration depth of the materials was evaluated using one- way ANOVA, and the Tukey test was used for comparisons between groups at p < 0.05 significance level.

Results: There was no significant difference in penetration depth between the Biodentine and NeoMTA 2 materials. NeoPUTTY showed higher penetration depth than Biodentine and NeoMTA 2.

Conclusions: This study reported that NeoPUTTY showed higher dentinal tubule penetration in primary teeth than NeoMTA 2 and Biodentine as pulpotomy materials.

生物牙本质,NeoMTA 2和NeoPUTTY在初级牙髓切开术中渗透到牙本质小管:共聚焦激光扫描显微镜分析。
背景:牙髓切开术是一种公认的治疗选择,用于保护因龋齿或外伤导致牙髓外露的乳牙,并确保其正常功能直到生理性脱落。本研究旨在利用共聚焦激光扫描显微镜(CLSM)评估NeoMTA 2、NeoPUTTY和Biodentine对牙本质的渗透程度。方法:采用42颗新鲜拔除的下一磨牙进行实验。所有样品分为3组,分别将Biodentine、NeoMTA 2和NeoPUTTY放置于空腔底。高速金刚石圆盘从分叉区形成2mm厚的切片,包括1 mm的冠和1 mm的根。将第一磨牙切片放在玻璃载玻片上,使用CLSM (LSM 980,蔡司,德国)进行检查。使用ImageJ/Fiji(美国国立卫生研究院)软件分析所有图像,测量穿透深度。采用单因素方差分析评估材料的穿透深度,并采用Tukey检验进行组间比较,p值为p。结果:Biodentine和NeoMTA 2材料的穿透深度无显著差异。NeoPUTTY的穿透深度高于Biodentine和NeoMTA 2。结论:本研究报道了NeoPUTTY作为切牙材料在乳牙中表现出比NeoMTA 2和Biodentine更高的牙本质小管渗透。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信