Ultra-sensitive MDM plasmonic sensor for refractive index, CO2 concentration, biomolecule, and temperature detection

IF 3 Q2 PHYSICS, CONDENSED MATTER
Diksha Chauhan , Ram Prakash Dwivedi , Zen Sbeah , Vishal Sorathiya , Sheng Hsiung Chang
{"title":"Ultra-sensitive MDM plasmonic sensor for refractive index, CO2 concentration, biomolecule, and temperature detection","authors":"Diksha Chauhan ,&nbsp;Ram Prakash Dwivedi ,&nbsp;Zen Sbeah ,&nbsp;Vishal Sorathiya ,&nbsp;Sheng Hsiung Chang","doi":"10.1016/j.micrna.2025.208211","DOIUrl":null,"url":null,"abstract":"<div><div>This paper presents a metal-dielectric-metal configuration based plasmonic refractive index sensor for applications like gas, biomolecule and temperature detection. The device consists of a rectangular ring resonator coupled to a straight waveguide. Initially the device has shown its application as a simple refractive index sensor, where the device can sense refractive indexes in the range from 1.0 to 1.1 with the maximum sensitivity of 2400 nm/refractive index unit (RIU). This device is used as a gas sensor for detecting the concentration of CO<sub>2</sub>, for that Polyhexamethylene biguanide (PHMB) is added to the rectangular ring resonator and then by changing the refractive index of PHMB layer via adsorbing CO<sub>2</sub> molecules, the change in the concentration of CO<sub>2</sub> gas is detected. A sensitivity of 46.51 p.m./parts per million (ppm) is theoretically obtained for the different concentrations of CO<sub>2</sub> from 0 ppm to 524 ppm. Then the device is simulated to sense various biomolecules, where detection of colorless biomaterial, anemia, creatinine and prostate cancer is performed. In the detection of anemia, the sensitivity of 3333nm/RIU is predicted. Additionally, for colorless biomolecules, static sensitivity of 2000 nm/RIU, for creatinine maximum sensitivity of 1500nm/RIU and maximum sensitivity of 2259.8 nm/RIU is predicted for prostate. Besides, this device is also used as a temperature sensor by using the Polydimethylsiloxane (PDMS) as the dielectric material, whose refractive index changes from 1.3861 to 1.4041 for different temperatures ranging between 80 °C and 20 °C. For the temperature detection, the sensitivity of 2 nm/°C is predicted.</div></div>","PeriodicalId":100923,"journal":{"name":"Micro and Nanostructures","volume":"205 ","pages":"Article 208211"},"PeriodicalIF":3.0000,"publicationDate":"2025-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Micro and Nanostructures","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2773012325001402","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHYSICS, CONDENSED MATTER","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents a metal-dielectric-metal configuration based plasmonic refractive index sensor for applications like gas, biomolecule and temperature detection. The device consists of a rectangular ring resonator coupled to a straight waveguide. Initially the device has shown its application as a simple refractive index sensor, where the device can sense refractive indexes in the range from 1.0 to 1.1 with the maximum sensitivity of 2400 nm/refractive index unit (RIU). This device is used as a gas sensor for detecting the concentration of CO2, for that Polyhexamethylene biguanide (PHMB) is added to the rectangular ring resonator and then by changing the refractive index of PHMB layer via adsorbing CO2 molecules, the change in the concentration of CO2 gas is detected. A sensitivity of 46.51 p.m./parts per million (ppm) is theoretically obtained for the different concentrations of CO2 from 0 ppm to 524 ppm. Then the device is simulated to sense various biomolecules, where detection of colorless biomaterial, anemia, creatinine and prostate cancer is performed. In the detection of anemia, the sensitivity of 3333nm/RIU is predicted. Additionally, for colorless biomolecules, static sensitivity of 2000 nm/RIU, for creatinine maximum sensitivity of 1500nm/RIU and maximum sensitivity of 2259.8 nm/RIU is predicted for prostate. Besides, this device is also used as a temperature sensor by using the Polydimethylsiloxane (PDMS) as the dielectric material, whose refractive index changes from 1.3861 to 1.4041 for different temperatures ranging between 80 °C and 20 °C. For the temperature detection, the sensitivity of 2 nm/°C is predicted.
超灵敏MDM等离子体传感器,用于折射率、CO2浓度、生物分子和温度检测
本文提出了一种基于金属-介电-金属结构的等离子体折射率传感器,可用于气体、生物分子和温度检测。该装置由一个矩形环形谐振器耦合到一个直波导。最初,该器件已显示出其作为一个简单的折射率传感器的应用,该器件可以感知1.0到1.1范围内的折射率,最大灵敏度为2400 nm/折射率单位(RIU)。该装置作为检测CO2浓度的气体传感器,在矩形环形谐振器中加入聚六亚甲基二胍(PHMB),通过吸附CO2分子改变PHMB层的折射率,从而检测CO2气体浓度的变化。理论上,从0 ppm到524 ppm不同浓度的CO2,灵敏度为46.51 pm / ppm (ppm)。然后模拟该装置来感知各种生物分子,其中检测无色生物材料,贫血,肌酐和前列腺癌。在贫血检测中,预测灵敏度为3333nm/RIU。此外,对于无色生物分子,前列腺的静态灵敏度为2000 nm/RIU,肌酐的最大灵敏度为1500nm/RIU,最大灵敏度为2259.8 nm/RIU。此外,该器件还使用聚二甲基硅氧烷(PDMS)作为介电材料作为温度传感器,在80 ~ 20℃的温度范围内,PDMS的折射率在1.3861 ~ 1.4041之间变化。对于温度检测,预测灵敏度为2 nm/°C。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信