Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values.

IF 0.7 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Advanced biomedical research Pub Date : 2025-01-30 eCollection Date: 2025-01-01 DOI:10.4103/abr.abr_313_24
Rashmit Kumar, Kurian Punnoose, Meenakumari Chikkanna, Srikanth Gunturu, Mosa Mohammad Alrifai, Abdulghani Saeed Al Zahrani, J Suresh Babu, C Swarnalatha, Abhishek Singh Nayyar
{"title":"Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values.","authors":"Rashmit Kumar, Kurian Punnoose, Meenakumari Chikkanna, Srikanth Gunturu, Mosa Mohammad Alrifai, Abdulghani Saeed Al Zahrani, J Suresh Babu, C Swarnalatha, Abhishek Singh Nayyar","doi":"10.4103/abr.abr_313_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>One of the major drawbacks of cone beam computed tomography (cone beam CT) is that unlike CT, the gray density values obtained from cone beam CT are relative, and not absolute as obtained in the case of CT. The present study was conducted with the intent to perform a comparative bone densitometric analysis using cone beam CT and CT and to determine if there was a mathematical correlation between the two.</p><p><strong>Materials and methods: </strong>The present in-vitro study included CT and cone beam CT scans of 30 dry mandibles wherein the gray density values from well-demarcated, precise anatomical areas were obtained, analyzed, and compared. Also, the dependent <i>t</i>-test and Pearson's correlation coefficient test were used for statistical analysis, while probability values (<i>P</i> values) < 0.05 were contemplated as being statistically significant.</p><p><strong>Results: </strong>Pearson's correlation between the gray density values for different combinations of point(s)/group(s) as derived on CT and cone beam CT images revealed the results to be statistically significant for each of the imaging methods used, individually and when compared in between the two methods, in all the cases (<i>P</i> < 0.001) when analyzed at 5% level of significance.</p><p><strong>Conclusions: </strong>The mean gray density values obtained with cone beam CT were found to be significantly higher than the ones derived from CT in the present study, though, a linear correlation was observed between the values obtained from cone beam CT and CT, which can be used to convert the relative values obtained with cone beam CT into absolute values derived with CT.</p>","PeriodicalId":94292,"journal":{"name":"Advanced biomedical research","volume":"14 ","pages":"8"},"PeriodicalIF":0.7000,"publicationDate":"2025-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11981036/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced biomedical research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/abr.abr_313_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: One of the major drawbacks of cone beam computed tomography (cone beam CT) is that unlike CT, the gray density values obtained from cone beam CT are relative, and not absolute as obtained in the case of CT. The present study was conducted with the intent to perform a comparative bone densitometric analysis using cone beam CT and CT and to determine if there was a mathematical correlation between the two.

Materials and methods: The present in-vitro study included CT and cone beam CT scans of 30 dry mandibles wherein the gray density values from well-demarcated, precise anatomical areas were obtained, analyzed, and compared. Also, the dependent t-test and Pearson's correlation coefficient test were used for statistical analysis, while probability values (P values) < 0.05 were contemplated as being statistically significant.

Results: Pearson's correlation between the gray density values for different combinations of point(s)/group(s) as derived on CT and cone beam CT images revealed the results to be statistically significant for each of the imaging methods used, individually and when compared in between the two methods, in all the cases (P < 0.001) when analyzed at 5% level of significance.

Conclusions: The mean gray density values obtained with cone beam CT were found to be significantly higher than the ones derived from CT in the present study, though, a linear correlation was observed between the values obtained from cone beam CT and CT, which can be used to convert the relative values obtained with cone beam CT into absolute values derived with CT.

使用锥形束计算机断层扫描(锥束CT)和计算机断层扫描(CT)进行骨密度测量分析:建立预测值和实际值之间的相关性。
背景:锥形束计算机断层扫描(cone beam CT)的主要缺点之一是,与CT不同,锥形束CT获得的灰度密度值是相对的,而不是像CT那样获得的绝对值。本研究的目的是使用锥形束CT和CT进行比较骨密度分析,并确定两者之间是否存在数学相关性。材料和方法:本体外研究包括30块干下颌骨的CT和锥束CT扫描,其中从明确划分的精确解剖区域获得灰色密度值,并进行分析和比较。采用相关t检验和Pearson相关系数检验进行统计分析,以概率值(P值)< 0.05为差异有统计学意义。结果:在CT和锥束CT图像上得出的不同点/组组合的灰度密度值之间的Pearson相关性显示,在所有情况下,当以5%的显著性水平分析时,所使用的每种成像方法单独和两种方法之间的比较结果均具有统计学意义(P < 0.001)。结论:本研究发现锥束CT的平均灰度密度值明显高于CT,但锥束CT与CT的灰度密度值呈线性相关,可将锥束CT的相对值转化为CT的绝对值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信