Practice of oxygen administration in patients hospitalized in internal medicine wards and intensive care units: A single-center prospective, observational study.

IF 1.3 4区 医学 Q2 MEDICINE, GENERAL & INTERNAL
Sao Paulo Medical Journal Pub Date : 2025-05-02 eCollection Date: 2025-01-01 DOI:10.1590/1516-3180.2024.0323.29012025
Saliha Bozkurt Esengul, Arzu Topeli, Burcin Halacli
{"title":"Practice of oxygen administration in patients hospitalized in internal medicine wards and intensive care units: A single-center prospective, observational study.","authors":"Saliha Bozkurt Esengul, Arzu Topeli, Burcin Halacli","doi":"10.1590/1516-3180.2024.0323.29012025","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Oxygen is widely used to treat hypoxemia.</p><p><strong>Objective: </strong>To determine the frequency of inappropriate oxygen administration in patients admitted to Internal Medicine (IM) wards and intensive care units (ICU).</p><p><strong>Design and setting: </strong>Single-center prospective, observational study in a tertiary university hospital in Ankara, Türkiye.</p><p><strong>Methods: </strong>Patients who were hospitalized in the IM wards and ICU and were receiving oxygen were recruited. Every 6 hours, the oxygenation parameters were noted, and the averages over the first 24 hours of oxygen usage were recorded. Inappropriate usage was defined as oxygen flow rates > 6 L/min in the nasal cannula and < 5 L/min and > 10 L/min in the simple face mask, application of the simple face mask in chronic obstructive lung disease (COPD) exacerbation, SpO2 > 98% in general, or SpO2 > 92% in COPD exacerbation.</p><p><strong>Results: </strong>Of the 397 patients, 20% in the IM wards and 50% of 124 in the ICU received oxygen. The oxygen method used was nasal cannula in 51%, simple face mask in 21%, and high-flow nasal cannula in 4% of the patients. Among the simple face mask applications, 46% were < 5 L/min and 5% were > 10 L/min. Among the 62% of patients with COPD exacerbations, the SpO2 was > 92%.</p><p><strong>Conclusion: </strong>The frequency of oxygen use was 20% among patients hospitalized in IM wards and 50% among patients in the ICU. Almost half of the simple face mask applications were inappropriate.</p>","PeriodicalId":49574,"journal":{"name":"Sao Paulo Medical Journal","volume":"143 3","pages":"e2024323"},"PeriodicalIF":1.3000,"publicationDate":"2025-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12052265/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sao Paulo Medical Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1516-3180.2024.0323.29012025","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Oxygen is widely used to treat hypoxemia.

Objective: To determine the frequency of inappropriate oxygen administration in patients admitted to Internal Medicine (IM) wards and intensive care units (ICU).

Design and setting: Single-center prospective, observational study in a tertiary university hospital in Ankara, Türkiye.

Methods: Patients who were hospitalized in the IM wards and ICU and were receiving oxygen were recruited. Every 6 hours, the oxygenation parameters were noted, and the averages over the first 24 hours of oxygen usage were recorded. Inappropriate usage was defined as oxygen flow rates > 6 L/min in the nasal cannula and < 5 L/min and > 10 L/min in the simple face mask, application of the simple face mask in chronic obstructive lung disease (COPD) exacerbation, SpO2 > 98% in general, or SpO2 > 92% in COPD exacerbation.

Results: Of the 397 patients, 20% in the IM wards and 50% of 124 in the ICU received oxygen. The oxygen method used was nasal cannula in 51%, simple face mask in 21%, and high-flow nasal cannula in 4% of the patients. Among the simple face mask applications, 46% were < 5 L/min and 5% were > 10 L/min. Among the 62% of patients with COPD exacerbations, the SpO2 was > 92%.

Conclusion: The frequency of oxygen use was 20% among patients hospitalized in IM wards and 50% among patients in the ICU. Almost half of the simple face mask applications were inappropriate.

内科病房和重症监护病房住院患者给氧的实践:一项单中心前瞻性观察性研究
背景:氧气被广泛用于治疗低氧血症。目的:了解内科(IM)病房和重症监护病房(ICU)住院患者给氧不当的发生率。设计和环境:在土耳其安卡拉的一所三级大学医院进行的单中心前瞻性观察研究。方法:选取内科及ICU住院并接受吸氧治疗的患者。每6小时记录一次氧合参数,并记录前24小时的平均耗氧量。不恰当的使用定义为鼻插管氧流量bbb60 L/min,简易面罩氧流量>0 L/min,简易面罩在慢性阻塞性肺疾病(COPD)加重期使用,SpO2 >一般为98%,COPD加重期为92%。结果:397例患者中,IM病房占20%,ICU 124例占50%。51%的患者使用鼻插管,21%的患者使用简易面罩,4%的患者使用高流量鼻插管。在简单口罩应用中,46% < 5 L/min, 5% < 10 L/min。在62%的COPD加重患者中,SpO2为0.92%。结论:IM病房住院患者的吸氧频率为20%,ICU住院患者的吸氧频率为50%。近一半的简单口罩使用不当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Sao Paulo Medical Journal
Sao Paulo Medical Journal 医学-医学:内科
CiteScore
2.20
自引率
7.10%
发文量
210
审稿时长
6-12 weeks
期刊介绍: Published bimonthly by the Associação Paulista de Medicina, the journal accepts articles in the fields of clinical health science (internal medicine, gynecology and obstetrics, mental health, surgery, pediatrics and public health). Articles will be accepted in the form of original articles (clinical trials, cohort, case-control, prevalence, incidence, accuracy and cost-effectiveness studies and systematic reviews with or without meta-analysis), narrative reviews of the literature, case reports, short communications and letters to the editor. Papers with a commercial objective will not be accepted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信