Takeshi Ogura, Saori Ueno, Akitoshi Hakoda, Atsushi Okuda, Nobu Nishioka, Jun Sakamoto, Jun Matsuno, Yuki Uba, Mitsuki Tomita, Nobuhiro Hattori, Junichi Nakamura, Kimi Bessho, Taro Iwatsubo, Toshifumi Yamaguchi, Ahmad F Aboelezz, Hiroki Nishikawa
{"title":"Balloon Catheter Versus Drill Dilator for EUS-Guided Hepaticogastrostomy Stent Placement: A Randomized Clinical Trial.","authors":"Takeshi Ogura, Saori Ueno, Akitoshi Hakoda, Atsushi Okuda, Nobu Nishioka, Jun Sakamoto, Jun Matsuno, Yuki Uba, Mitsuki Tomita, Nobuhiro Hattori, Junichi Nakamura, Kimi Bessho, Taro Iwatsubo, Toshifumi Yamaguchi, Ahmad F Aboelezz, Hiroki Nishikawa","doi":"10.1002/ueg2.70044","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>A novel partially self-expandable metal stent (PCSEMS) with an anti-migration system has recently become available during Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) but requires tract dilation. No previous study has compared the performance of dilation devices during EUS-HGS. The aim of this randomized controlled trial was to evaluate the technical success rate of tract dilation between a balloon catheter and drill dilator technique during EUS-HGS prior to insertion of SEMS with an anti-migration system.</p><p><strong>Methods: </strong>A single-center, randomized controlled trial comparing the balloon dilation and drill dilator techniques for first-line tract dilation during EUS-HGS. The primary outcome was the initial technical success rate of tract dilation for each technique during EUS-HGS. The secondary outcome was adverse events associated with the procedures.</p><p><strong>Results: </strong>Of 54 randomized patients who underwent EUS-HGS at our center, there were 27 in the balloon dilation group and 27 in the drill dilation group. The initial technical success rate was 92.6% (25/27) in the balloon dilation group and 100% (27/27) in the drill dilation group (p = 0.1495). The technical success rate of stent delivery system insertion was significantly higher in the balloon dilation group (88%, 22/25) than in the drill dilation group (45%, 13/27; p = 0.0013). Procedure time was significantly shorter in the balloon dilation group (mean, 9.7 min) than in the drill dilation group (mean, 14.0 min; p = 0.047). Adverse events were more frequent in the drill dilation group (7.4% vs. 29.6%, p = 0.038).</p><p><strong>Conclusions: </strong>Balloon dilation appears more suitable than drill dilation for PCSEMS with 8.5 Fr stent delivery system deployment.</p><p><strong>Clinical trial registration number: </strong>University Hospital Medical Information Network 000049550.</p>","PeriodicalId":23444,"journal":{"name":"United European Gastroenterology Journal","volume":" ","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2025-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"United European Gastroenterology Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/ueg2.70044","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: A novel partially self-expandable metal stent (PCSEMS) with an anti-migration system has recently become available during Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) but requires tract dilation. No previous study has compared the performance of dilation devices during EUS-HGS. The aim of this randomized controlled trial was to evaluate the technical success rate of tract dilation between a balloon catheter and drill dilator technique during EUS-HGS prior to insertion of SEMS with an anti-migration system.
Methods: A single-center, randomized controlled trial comparing the balloon dilation and drill dilator techniques for first-line tract dilation during EUS-HGS. The primary outcome was the initial technical success rate of tract dilation for each technique during EUS-HGS. The secondary outcome was adverse events associated with the procedures.
Results: Of 54 randomized patients who underwent EUS-HGS at our center, there were 27 in the balloon dilation group and 27 in the drill dilation group. The initial technical success rate was 92.6% (25/27) in the balloon dilation group and 100% (27/27) in the drill dilation group (p = 0.1495). The technical success rate of stent delivery system insertion was significantly higher in the balloon dilation group (88%, 22/25) than in the drill dilation group (45%, 13/27; p = 0.0013). Procedure time was significantly shorter in the balloon dilation group (mean, 9.7 min) than in the drill dilation group (mean, 14.0 min; p = 0.047). Adverse events were more frequent in the drill dilation group (7.4% vs. 29.6%, p = 0.038).
Conclusions: Balloon dilation appears more suitable than drill dilation for PCSEMS with 8.5 Fr stent delivery system deployment.
Clinical trial registration number: University Hospital Medical Information Network 000049550.
期刊介绍:
United European Gastroenterology Journal (UEG Journal) is the official Journal of the United European Gastroenterology (UEG), a professional non-profit organisation combining all the leading European societies concerned with digestive disease. UEG’s member societies represent over 22,000 specialists working across medicine, surgery, paediatrics, GI oncology and endoscopy, which makes UEG a unique platform for collaboration and the exchange of knowledge.