Jade Ward, Emilio Verucchi, Dave Swaile, Katie Parker, Peter R Worsley, Davide Filingeri
{"title":"Effects of Stimulus Temperature and Skin Hydration Levels on Wetness Perception at the Underarm.","authors":"Jade Ward, Emilio Verucchi, Dave Swaile, Katie Parker, Peter R Worsley, Davide Filingeri","doi":"10.1111/srt.70170","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Experiencing wetness on the skin because of sweating or contact with fluids can induce thermal discomfort. Millions of people apply antiperspirant deodorant products to the underarm to minimise this negative experience. However, the mechanisms underpinning wetness perception at the underarm and the influence of underlying stratum corneum hydration remain under investigation. We aimed to evaluate the role of stimulus temperature and skin hydration levels on wetness perception at the underarm in young participants.</p><p><strong>Materials and methods: </strong>Ten healthy participants (5 M/5 F; 29 ± 7 years) underwent a quantitative sensory test during which they reported the perceived magnitude of wetness perception from a short-duration static application of a cold-wet (i.e., 5°C below local skin temperature), neutral-wet (i.e., equal to local skin temperature) and warm-wet (i.e., 5°C above local skin temperature) stimuli. Wetness perception was assessed on a 100-mm visual analogue scale (0 = dry; 100 = completely wet), with a repeated measures design exploring the effects of overhydration (+21 %) and dehydration (-40 %) of the underarm's skin.</p><p><strong>Results: </strong>Our results indicated a higher wetness perception (p = 0.012) during the cold-wet (40 mm, 95 % CI: 25, 56) than during the warm-wet (25 mm, 95 % CI: 12, 39), and neutral-wet stimuli (24 mm, 95 % CI: 7, 40). Furthermore, overhydration of the underarm' stratum corneum can lead to an increase in wetness perceptions upon contact with cold-wet stimuli only (mean increase: 20 mm, 95 % CI: 3, 36; p = 0.024; corresponding to 20 % increase).</p><p><strong>Conclusion: </strong>Our findings provide novel fundamental insights into the underarm's perceptual responses to wetness, which could inform understanding of the determinants of wet feel associated with periods of sweating and the application of antiperspirant products.</p>","PeriodicalId":21746,"journal":{"name":"Skin Research and Technology","volume":"31 2-5","pages":"e70170"},"PeriodicalIF":3.2000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12077280/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Skin Research and Technology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/srt.70170","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DERMATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Experiencing wetness on the skin because of sweating or contact with fluids can induce thermal discomfort. Millions of people apply antiperspirant deodorant products to the underarm to minimise this negative experience. However, the mechanisms underpinning wetness perception at the underarm and the influence of underlying stratum corneum hydration remain under investigation. We aimed to evaluate the role of stimulus temperature and skin hydration levels on wetness perception at the underarm in young participants.
Materials and methods: Ten healthy participants (5 M/5 F; 29 ± 7 years) underwent a quantitative sensory test during which they reported the perceived magnitude of wetness perception from a short-duration static application of a cold-wet (i.e., 5°C below local skin temperature), neutral-wet (i.e., equal to local skin temperature) and warm-wet (i.e., 5°C above local skin temperature) stimuli. Wetness perception was assessed on a 100-mm visual analogue scale (0 = dry; 100 = completely wet), with a repeated measures design exploring the effects of overhydration (+21 %) and dehydration (-40 %) of the underarm's skin.
Results: Our results indicated a higher wetness perception (p = 0.012) during the cold-wet (40 mm, 95 % CI: 25, 56) than during the warm-wet (25 mm, 95 % CI: 12, 39), and neutral-wet stimuli (24 mm, 95 % CI: 7, 40). Furthermore, overhydration of the underarm' stratum corneum can lead to an increase in wetness perceptions upon contact with cold-wet stimuli only (mean increase: 20 mm, 95 % CI: 3, 36; p = 0.024; corresponding to 20 % increase).
Conclusion: Our findings provide novel fundamental insights into the underarm's perceptual responses to wetness, which could inform understanding of the determinants of wet feel associated with periods of sweating and the application of antiperspirant products.
期刊介绍:
Skin Research and Technology is a clinically-oriented journal on biophysical methods and imaging techniques and how they are used in dermatology, cosmetology and plastic surgery for noninvasive quantification of skin structure and functions. Papers are invited on the development and validation of methods and their application in the characterization of diseased, abnormal and normal skin.
Topics include blood flow, colorimetry, thermography, evaporimetry, epidermal humidity, desquamation, profilometry, skin mechanics, epiluminiscence microscopy, high-frequency ultrasonography, confocal microscopy, digital imaging, image analysis and computerized evaluation and magnetic resonance. Noninvasive biochemical methods (such as lipids, keratin and tissue water) and the instrumental evaluation of cytological and histological samples are also covered.
The journal has a wide scope and aims to link scientists, clinical researchers and technicians through original articles, communications, editorials and commentaries, letters, reviews, announcements and news. Contributions should be clear, experimentally sound and novel.