Assessment of different shielding materials for radiation therapy of maxillofacial tumors - An in vitro study.

IF 1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
K Kasim Mohamed, K Satish Srinivas, Madhankumar Seenivasan, Annapoorani Babu
{"title":"Assessment of different shielding materials for radiation therapy of maxillofacial tumors - An in vitro study.","authors":"K Kasim Mohamed, K Satish Srinivas, Madhankumar Seenivasan, Annapoorani Babu","doi":"10.4103/jips.jips_570_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>Since the advent of radiotherapy, the success rate of head and neck cancer treatment has increased significantly. However, when the tissue tolerance level is exceeded, unnecessary and uncontrolled exposure to radiation is considered detrimental. Such problems remain difficult to prevent and manage. The aim of the study to evaluate and compare the degree of attenuation of therapeutic radiation using four different radiation shielding materials of varying thickness.</p><p><strong>Study setting and design: </strong>In vitro experimental study.</p><p><strong>Materials and methods: </strong>The samples were divided into four groups based on the different radiation shielding materials of thickness 3mm and 5mm. The materials are Lead (Pb), Silver-tin alloy (Ag-Sn) with Polyvinylsiloxane (PVS), Polymethylmethacrylate (PMMA) with Barium sulphate (BaSO4), and a combination of Ag-Sn with PVS and PMMA with BaSO4 which was exposed to radiation. The radiation dose measurements were recorded and the radiation attenuation properties of the shielding materials were evaluated. Among all of the shielding materials the most efficient material under consideration is determined.</p><p><strong>Statistical analysis used: </strong>One-way ANOVA followed by post hoc test was used to compare the means of all four groups.</p><p><strong>Results: </strong>A statistically significant difference between groups was found by a one-way ANOVA with a P = 0.001. In the post hoc test, statistically significant findings were obtained with a P = 0.05 when comparing the variation values of 3mm and 5mm thickness between each group and other groups.</p><p><strong>Conclusion: </strong>The shielding materials results in significant reductions in radiation dosage. It was concluded that the combinations of Ag-Sn alloy with PVS, and PMMA with BaSO4 of thickness 5 mm had a good shielding effect.</p>","PeriodicalId":22669,"journal":{"name":"The Journal of Indian Prosthodontic Society","volume":"24 4","pages":"381-386"},"PeriodicalIF":1.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11614121/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Indian Prosthodontic Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jips.jips_570_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/15 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: Since the advent of radiotherapy, the success rate of head and neck cancer treatment has increased significantly. However, when the tissue tolerance level is exceeded, unnecessary and uncontrolled exposure to radiation is considered detrimental. Such problems remain difficult to prevent and manage. The aim of the study to evaluate and compare the degree of attenuation of therapeutic radiation using four different radiation shielding materials of varying thickness.

Study setting and design: In vitro experimental study.

Materials and methods: The samples were divided into four groups based on the different radiation shielding materials of thickness 3mm and 5mm. The materials are Lead (Pb), Silver-tin alloy (Ag-Sn) with Polyvinylsiloxane (PVS), Polymethylmethacrylate (PMMA) with Barium sulphate (BaSO4), and a combination of Ag-Sn with PVS and PMMA with BaSO4 which was exposed to radiation. The radiation dose measurements were recorded and the radiation attenuation properties of the shielding materials were evaluated. Among all of the shielding materials the most efficient material under consideration is determined.

Statistical analysis used: One-way ANOVA followed by post hoc test was used to compare the means of all four groups.

Results: A statistically significant difference between groups was found by a one-way ANOVA with a P = 0.001. In the post hoc test, statistically significant findings were obtained with a P = 0.05 when comparing the variation values of 3mm and 5mm thickness between each group and other groups.

Conclusion: The shielding materials results in significant reductions in radiation dosage. It was concluded that the combinations of Ag-Sn alloy with PVS, and PMMA with BaSO4 of thickness 5 mm had a good shielding effect.

颌面部肿瘤放射治疗中不同屏蔽材料的体外研究。
目的:自放疗出现以来,头颈部肿瘤的治疗成功率显著提高。然而,当超过组织耐受水平时,不必要和不受控制的辐射暴露被认为是有害的。这些问题仍然难以预防和管理。本研究的目的是评估和比较使用四种不同厚度的辐射屏蔽材料治疗辐射的衰减程度。研究设置与设计:体外实验研究。材料与方法:根据屏蔽材料的厚度分别为3mm和5mm,将样品分为四组。材料包括铅(Pb)、银锡合金(Ag-Sn)与聚乙烯硅氧烷(PVS)、聚甲基丙烯酸甲酯(PMMA)与硫酸钡(BaSO4)、Ag-Sn与PVS、PMMA与BaSO4的组合。记录了辐射剂量测量结果,并对屏蔽材料的辐射衰减性能进行了评价。在所有的屏蔽材料中,确定了最有效的屏蔽材料。采用统计学分析:采用单因素方差分析和事后检验比较四组的均数。结果:经单因素方差分析,组间差异有统计学意义,P = 0.001。事后检验中,各组与其他组3mm、5mm厚度变化值比较,P = 0.05,有统计学意义。结论:屏蔽材料能显著降低辐射剂量。结果表明,Ag-Sn合金与PVS复合,PMMA与厚度为5 mm的BaSO4复合具有良好的屏蔽效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
The Journal of Indian Prosthodontic Society
The Journal of Indian Prosthodontic Society DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.20
自引率
8.30%
发文量
26
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信