F Chen, Z G Zhao, X Wei, Y J Liang, Z K Zhu, Y J Yao, X Li, Q Li, J F Wei, W Meng, Y Peng, Y Feng, M Chen
{"title":"[Feasibility study of transjugular tricuspid valve replacement for the treatment of tricuspid regurgitation].","authors":"F Chen, Z G Zhao, X Wei, Y J Liang, Z K Zhu, Y J Yao, X Li, Q Li, J F Wei, W Meng, Y Peng, Y Feng, M Chen","doi":"10.3760/cma.j.cn112148-20250127-00072","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To evaluate the feasibility of transjugular transcatheter tricuspid valve replacement (TTVR) using the LuX-Valve Plus system (Ningbo Jenscare Scientific, China) for the treatment of severe tricuspid regurgitation in real-world clinical settings. <b>Methods:</b> This prospective study enrolled 81 patients with severe ricuspid regurgitation (≥3+) who underwent TTVR with the LuX-Valve Plus system at the Department of Cardiology, West China Hospital of Sichuan University between May 2022 and March 2024. Among them, 44 patients were from a compassionate-use study, and 37 were from two premarket clinical trials. Baseline clinical data, preprocedural imaging, procedural outcomes, and postprocedural follow-up data were collected. The primary endpoint events included device success, procedural success, and 30 d composite adverse events. <b>Results:</b> The age of the cohort was (74.5±7.8) years, with 54 females (67%). Device success and procedural success rates were both 90% (73/81). Post-procedural tricuspid regurgitation improved, with a 6% (5/81) incidence of moderate-to-severe paravalvular leakage. The rate of permanent pacemaker implantation was 12% (10/81), of which 5% (4/81) had pre-existing indications for pacemaker implantation. Major bleeding events occurred in 10% (8/81) of patients, and the 30 d composite endpoint rate was 25% (20/81). <b>Conclusion:</b> TTVR using the LuX-Valve Plus system demonstrates promising feasibility for high-risk surgical patients with severe tricuspid regurgitation, effectively reducing or eliminating regurgitation with acceptable safety. However, challenges remain in reducing risks of major adverse events, including permanent pacemaker implantation and severe bleeding.</p>","PeriodicalId":38755,"journal":{"name":"中华心血管病杂志","volume":"53 4","pages":"363-372"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华心血管病杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn112148-20250127-00072","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To evaluate the feasibility of transjugular transcatheter tricuspid valve replacement (TTVR) using the LuX-Valve Plus system (Ningbo Jenscare Scientific, China) for the treatment of severe tricuspid regurgitation in real-world clinical settings. Methods: This prospective study enrolled 81 patients with severe ricuspid regurgitation (≥3+) who underwent TTVR with the LuX-Valve Plus system at the Department of Cardiology, West China Hospital of Sichuan University between May 2022 and March 2024. Among them, 44 patients were from a compassionate-use study, and 37 were from two premarket clinical trials. Baseline clinical data, preprocedural imaging, procedural outcomes, and postprocedural follow-up data were collected. The primary endpoint events included device success, procedural success, and 30 d composite adverse events. Results: The age of the cohort was (74.5±7.8) years, with 54 females (67%). Device success and procedural success rates were both 90% (73/81). Post-procedural tricuspid regurgitation improved, with a 6% (5/81) incidence of moderate-to-severe paravalvular leakage. The rate of permanent pacemaker implantation was 12% (10/81), of which 5% (4/81) had pre-existing indications for pacemaker implantation. Major bleeding events occurred in 10% (8/81) of patients, and the 30 d composite endpoint rate was 25% (20/81). Conclusion: TTVR using the LuX-Valve Plus system demonstrates promising feasibility for high-risk surgical patients with severe tricuspid regurgitation, effectively reducing or eliminating regurgitation with acceptable safety. However, challenges remain in reducing risks of major adverse events, including permanent pacemaker implantation and severe bleeding.
中华心血管病杂志Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.40
自引率
0.00%
发文量
10577
期刊介绍:
The Chinese Journal of Cardiology , established in February 1973, is one of the major academic medical journals sponsored by the Chinese Medical Association and a leading periodical in the field of cardiology in China. It specializes in cardiology and related disciplines with a readership of more than 25 000. The journal publishes editorials and guidelines as well as important original articles on clinical and experimental investigations, reflecting achievements made in China and promoting academic communication between domestic and foreign cardiologists. The journal includes the following columns: Editorials, Strategies, Comments, Clinical Investigations, Experimental Investigations, Epidemiology and Prevention, Lectures, Comprehensive Reviews, Continuing Medical Education, etc.