In vitro comparison of different composite resins for aligner attachment production : Amount of adhesive flash, flash removal time, and shear bond strength.

IF 1.6 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Servet Erbas, Ezgi Atik
{"title":"In vitro comparison of different composite resins for aligner attachment production : Amount of adhesive flash, flash removal time, and shear bond strength.","authors":"Servet Erbas, Ezgi Atik","doi":"10.1007/s00056-025-00588-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The aim of this in vitro study was to determine the difference between aligner attachments constructed from four different composite resins in terms of adhesive flash amount, removal time, and shear bond strength.</p><p><strong>Materials and methods: </strong>In all, 80 extracted human premolars were divided into four groups (N = 20) based on the type of composites used for the fabrication of aligner attachments (Group 1: GC Aligner Connect and Group 2: GC Ortho Connect [both from GC Dental Products, Tokyo, Japan]; Group 3: Z350 XT flowable and Group 4: Filtek Z350 XT Universal [both from 3M Unitek, Monrovia, CA, USA]). After bonding, the attachments were scanned with the iTero Element® (Align® Technology, San Jose, CA, USA). The amount of adhesive flash in the overflowing areas was analyzed by comparing the bonded attachments before and after removing the adhesive flash via the software 3D Geomagic Control (3DS Systems, Rock Hill, SC, USA). A color map was used to reveal the percentage of overflowing resin. Flash adhesive removal time per tooth and shear bond strength of the attachments were also analyzed. The significance level was set at p < 0.05.</p><p><strong>Results: </strong>The median values for the overflowing flash adhesive (surface deviation values) were 0.26, 0.29, 0.35, and 0.26 mm for Groups 1, 2, 3, and 4, respectively, with a significant difference between the groups (3 > 1, 2, 4; p < 0.001, effect size (η<sup>2</sup>) = 0.215). The percentage of red color deviation in overflowing areas was mostly observed in Group 3 (58.8%), while the green color was mostly noted in Group 4 (25%; p < 0.05). The time for removal of the adhesive flash was significantly higher in Group 1 than in Groups 2, 3, and 4 (p < 0.001, η<sup>2</sup> = 0.340). The mean bond strength of Group 4 (19.27 ± 6.37 MPa) was higher than those of Groups 1 (11.42 ± 2.54 MPa) and 2 (14.43 ± 4.61 MPa; p < 0.001 and p = 0.015, η<sup>2</sup> = 0.261).</p><p><strong>Conclusion: </strong>Z350 XT flowable composite showed a higher overflow value and percentage of color deviation than the attachments made from the other resins. The universal restorative resin Filtek Z350 XT Universal was found to be advantageous in terms of both causing less flash adhesive and demonstrating higher bond strength to the tooth.</p>","PeriodicalId":54776,"journal":{"name":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2025-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orofacial Orthopedics-Fortschritte Der Kieferorthopadie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00056-025-00588-9","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The aim of this in vitro study was to determine the difference between aligner attachments constructed from four different composite resins in terms of adhesive flash amount, removal time, and shear bond strength.

Materials and methods: In all, 80 extracted human premolars were divided into four groups (N = 20) based on the type of composites used for the fabrication of aligner attachments (Group 1: GC Aligner Connect and Group 2: GC Ortho Connect [both from GC Dental Products, Tokyo, Japan]; Group 3: Z350 XT flowable and Group 4: Filtek Z350 XT Universal [both from 3M Unitek, Monrovia, CA, USA]). After bonding, the attachments were scanned with the iTero Element® (Align® Technology, San Jose, CA, USA). The amount of adhesive flash in the overflowing areas was analyzed by comparing the bonded attachments before and after removing the adhesive flash via the software 3D Geomagic Control (3DS Systems, Rock Hill, SC, USA). A color map was used to reveal the percentage of overflowing resin. Flash adhesive removal time per tooth and shear bond strength of the attachments were also analyzed. The significance level was set at p < 0.05.

Results: The median values for the overflowing flash adhesive (surface deviation values) were 0.26, 0.29, 0.35, and 0.26 mm for Groups 1, 2, 3, and 4, respectively, with a significant difference between the groups (3 > 1, 2, 4; p < 0.001, effect size (η2) = 0.215). The percentage of red color deviation in overflowing areas was mostly observed in Group 3 (58.8%), while the green color was mostly noted in Group 4 (25%; p < 0.05). The time for removal of the adhesive flash was significantly higher in Group 1 than in Groups 2, 3, and 4 (p < 0.001, η2 = 0.340). The mean bond strength of Group 4 (19.27 ± 6.37 MPa) was higher than those of Groups 1 (11.42 ± 2.54 MPa) and 2 (14.43 ± 4.61 MPa; p < 0.001 and p = 0.015, η2 = 0.261).

Conclusion: Z350 XT flowable composite showed a higher overflow value and percentage of color deviation than the attachments made from the other resins. The universal restorative resin Filtek Z350 XT Universal was found to be advantageous in terms of both causing less flash adhesive and demonstrating higher bond strength to the tooth.

不同复合树脂用于对准器附着物的体外比较:胶粘剂闪光量、闪光去除时间和剪切强度。
前言:本体外研究的目的是确定四种不同复合树脂构建的对准器附着物在胶粘剂闪光量、去除时间和剪切强度方面的差异。材料和方法:总共80颗提取的人类前磨牙,根据用于制作矫形器附件的复合材料类型分为四组(N = 20)(第1组:GC矫形器连接,第2组:GC矫形器连接[均来自日本东京的GC Dental Products];第3组:Z350 XT flowable和第4组:Filtek Z350 XT Universal[均来自3M Unitek, Monrovia, CA, USA])。粘接后,用iTero Element®(Align®Technology, San Jose, CA, USA)扫描附件。通过3D Geomagic Control软件(3DS Systems, Rock Hill, SC, USA),通过比较去除粘接闪光前后的粘接附件,分析溢区粘接闪光的数量。使用彩色地图显示溢出树脂的百分比。并分析了每齿闪胶去除时间和附着体的剪切强度。结果:1、2、3、4组的溢闪胶中位数(表面偏差值)分别为0.26、0.29、0.35、0.26 mm,组间差异有统计学意义(3 > 1,2,4; 2页) = 0.215)。第3组溢水区红色偏差多(58.8%),第4组溢水区绿色偏差多(25%);p 2 = 0.340)。4组的平均结合强度(19.27 ±6.37 MPa)高于1组(11.42 ±2.54 MPa)和2组(14.43 ±4.61 MPa);p 2 = 0.261)。结论:z350xt可流动复合材料具有较高的溢出值和色差率。通用修复树脂Filtek Z350 XT universal被发现在产生更少的闪胶和显示更高的牙齿粘合强度方面具有优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.90
自引率
0.00%
发文量
64
审稿时长
>12 weeks
期刊介绍: The Journal of Orofacial Orthopedics provides orthodontists and dentists who are also actively interested in orthodontics, whether in university clinics or private practice, with highly authoritative and up-to-date information based on experimental and clinical research. The journal is one of the leading publications for the promulgation of the results of original work both in the areas of scientific and clinical orthodontics and related areas. All articles undergo peer review before publication. The German Society of Orthodontics (DGKFO) also publishes in the journal important communications, statements and announcements.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信