Analysis of Adjusted Exposure Levels Based on Different Kurtosis Adjustment Algorithms and Their Performance Comparison in Evaluating Noise-Induced Hearing Loss.
IF 2.6 2区 医学Q1 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
{"title":"Analysis of Adjusted Exposure Levels Based on Different Kurtosis Adjustment Algorithms and Their Performance Comparison in Evaluating Noise-Induced Hearing Loss.","authors":"Hengjiang Liu, Meibian Zhang, Xin Sun, Weijiang Hu, Hua Zou, Jingsong Li, Wei Qiu","doi":"10.1097/AUD.0000000000001674","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Kurtosis is an essential metric in evaluating hearing loss caused by complex noise, which is calculated from the fourth central moment and the SD of the noise signal. Previous studies have shown that kurtosis-adjusted noise exposure levels can more accurately predict hearing loss caused by various types of noise. There are three potential kurtosis adjustment schemes: arithmetic averaging, geometric averaging, and segmented adjustment. This study evaluates which kurtosis adjustment scheme is most practical based on the data collected from industrial settings.</p><p><strong>Design: </strong>This study analyzed individual daily noise recordings collected from 4276 workers in manufacturing industries in China. Using 60 sec as the calculation window length, each window's noise kurtosis was calculated without overlap. Then, the arithmetic averaging (Scheme 1) and geometric averaging (Scheme 2) algorithms were used to calculate the kurtosis of the shift-long noise. Eventually, the kurtosis-adjusted 8 h working day exposure level (LAeq,8hr) was obtained using the kurtosis-adjusted formula. In Scheme 3 (i.e., segmented adjustment algorithm), kurtosis was determined per 60 sec simultaneously with A-weighted sound pressure level (LAeq,60sec). Kurtosis adjustment was applied on LAeq,60sec every 60 sec. Then, the kurtosis-adjusted LAeq,8hr was calculated by log-averaging of 480 one-minute-adjusted LAeq,60sec values. The cohort was divided into three groups according to the level of kurtosis. Which group the participants belonged to depended on the method used to calculate the shift-long noise kurtosis (i.e., arithmetic or geometric averaging). Noise-induced hearing loss was defined as noise-induced permanent threshold shift at frequencies 3, 4, and 6 kHz (NIPTS346). Predicted NIPTS346 was calculated using the ISO 1999 model or Lempert's model for each participant, and the actual NIPTS346 was determined by correcting for age and sex using non-noise-exposed Chinese workers (n = 1297). A dose-effect relationship for three kurtosis groups was established using the NIPTS346 and kurtosis-adjusted LAeq,8hr. The performance of three kurtosis adjustment algorithms was evaluated by comparing the estimated marginal mean of the difference between estimated NIPTS346 by ISO 1999 or estimated NIPTS346 by Lempert's model and actual NIPTS346 in three kurtosis groups.</p><p><strong>Results: </strong>Multiple linear regression was used to analyze the noise kurtosis classified data obtained by arithmetic and geometric averaging, and the calculated adjustment coefficients were 6.5 and 7.6, respectively. Multilayer perceptron regression was used to identify the optimal coefficients in the segmented adjustment, resulting in a coefficient value of 5.4. These three adjustment schemes were used to evaluate the performance of NIPTS346 prediction using Lempert's model. The kurtosis adjustment based on the geometric averaging algorithm (Scheme 2) and on the segmented adjustment (Scheme 3) demonstrated comparable performance and was much better than the arithmetic averaging algorithm.</p><p><strong>Conclusions: </strong>Evidence in this study indicated that using the kurtosis-adjusted LAeq,8hr by geometric averaging with an adjustment coefficient of 6.5 or by segmented adjustment with an adjustment coefficient of 5.4 could more accurately evaluate noise-induced hearing loss than by arithmetic averaging. The segmented adjustment provided a more flexible kurtosis adjustment scheme with a broader potential application prospect. However, the results of segmented adjustment can be severely affected by extreme values, and further research is needed to improve the accuracy and reliability of the segmented adjustment.</p>","PeriodicalId":55172,"journal":{"name":"Ear and Hearing","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2025-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ear and Hearing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/AUD.0000000000001674","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: Kurtosis is an essential metric in evaluating hearing loss caused by complex noise, which is calculated from the fourth central moment and the SD of the noise signal. Previous studies have shown that kurtosis-adjusted noise exposure levels can more accurately predict hearing loss caused by various types of noise. There are three potential kurtosis adjustment schemes: arithmetic averaging, geometric averaging, and segmented adjustment. This study evaluates which kurtosis adjustment scheme is most practical based on the data collected from industrial settings.
Design: This study analyzed individual daily noise recordings collected from 4276 workers in manufacturing industries in China. Using 60 sec as the calculation window length, each window's noise kurtosis was calculated without overlap. Then, the arithmetic averaging (Scheme 1) and geometric averaging (Scheme 2) algorithms were used to calculate the kurtosis of the shift-long noise. Eventually, the kurtosis-adjusted 8 h working day exposure level (LAeq,8hr) was obtained using the kurtosis-adjusted formula. In Scheme 3 (i.e., segmented adjustment algorithm), kurtosis was determined per 60 sec simultaneously with A-weighted sound pressure level (LAeq,60sec). Kurtosis adjustment was applied on LAeq,60sec every 60 sec. Then, the kurtosis-adjusted LAeq,8hr was calculated by log-averaging of 480 one-minute-adjusted LAeq,60sec values. The cohort was divided into three groups according to the level of kurtosis. Which group the participants belonged to depended on the method used to calculate the shift-long noise kurtosis (i.e., arithmetic or geometric averaging). Noise-induced hearing loss was defined as noise-induced permanent threshold shift at frequencies 3, 4, and 6 kHz (NIPTS346). Predicted NIPTS346 was calculated using the ISO 1999 model or Lempert's model for each participant, and the actual NIPTS346 was determined by correcting for age and sex using non-noise-exposed Chinese workers (n = 1297). A dose-effect relationship for three kurtosis groups was established using the NIPTS346 and kurtosis-adjusted LAeq,8hr. The performance of three kurtosis adjustment algorithms was evaluated by comparing the estimated marginal mean of the difference between estimated NIPTS346 by ISO 1999 or estimated NIPTS346 by Lempert's model and actual NIPTS346 in three kurtosis groups.
Results: Multiple linear regression was used to analyze the noise kurtosis classified data obtained by arithmetic and geometric averaging, and the calculated adjustment coefficients were 6.5 and 7.6, respectively. Multilayer perceptron regression was used to identify the optimal coefficients in the segmented adjustment, resulting in a coefficient value of 5.4. These three adjustment schemes were used to evaluate the performance of NIPTS346 prediction using Lempert's model. The kurtosis adjustment based on the geometric averaging algorithm (Scheme 2) and on the segmented adjustment (Scheme 3) demonstrated comparable performance and was much better than the arithmetic averaging algorithm.
Conclusions: Evidence in this study indicated that using the kurtosis-adjusted LAeq,8hr by geometric averaging with an adjustment coefficient of 6.5 or by segmented adjustment with an adjustment coefficient of 5.4 could more accurately evaluate noise-induced hearing loss than by arithmetic averaging. The segmented adjustment provided a more flexible kurtosis adjustment scheme with a broader potential application prospect. However, the results of segmented adjustment can be severely affected by extreme values, and further research is needed to improve the accuracy and reliability of the segmented adjustment.
期刊介绍:
From the basic science of hearing and balance disorders to auditory electrophysiology to amplification and the psychological factors of hearing loss, Ear and Hearing covers all aspects of auditory and vestibular disorders. This multidisciplinary journal consolidates the various factors that contribute to identification, remediation, and audiologic and vestibular rehabilitation. It is the one journal that serves the diverse interest of all members of this professional community -- otologists, audiologists, educators, and to those involved in the design, manufacture, and distribution of amplification systems. The original articles published in the journal focus on assessment, diagnosis, and management of auditory and vestibular disorders.